Descargas
Software & Firmware Archives
Firmware
2.0.5
22/09/2014
Ver todas las Actualizaciones
These release notes cover the following models:
- MXWNCS4/8
- MXWANI4/8
- MXWAPT4/8
NEW FEATURES
- Added new frequency band SKUs for Japan and Taiwan
- Added the ability to remotely identify a microphone without beeping the mic’s alarm
IMPROVEMENTS
- Moved the device IP Address Setting to the Utility Page, and enabled all IP edits to be batched.
- Fixed the compatibility issue with Mavericks “timing out” the MXWAPT GUI.
- Changed Factory reset button location to each individual device’s edit pop-up window.
- Updated the MXW Charger to be discoverable by the Shure Discovery Application 1.0.11 or higher
KNOWN ISSUES
- There may be issues staying connected to the GUI while using Safari on Mac OS X 10.9 Mavericks.
NOTES
- For operation of MXW devices with other Shure networked systems, see the following list of minimum software and firmware versions that are supported with MXW version 2.0.5:
- SCM820-DAN 1.1.211
- Shure Web Device Discovery 1.0.11
Firmware
1.0.15
9/09/2014
Ver todas las Actualizaciones
NOTES
- Initial release
- For operation of QLX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with QLX-D version 1.0.15:
- ULXD1/2 ULX-D Transmitters 1.5.6
- Wireless Workbench 6 version 6.10.0
Firmware
1.0.5
9/09/2014
Ver todas las Actualizaciones
NOTES
- Initial release
- For operation of QLX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with QLX-D version 1.0.15:
- ULXD1/2 ULX-D Transmitters 1.5.6
- Wireless Workbench 6 version 6.10.0
Software
2.1.0.21
28/08/2014
Ver todas las Actualizaciones
Improvements
- Added support for updating QLX-D devices, including
- QLXD1 - Bodypack transmitters
- QLXD2 - Handheld transmitters
- QLXD4 - Single channel receiver
Notes
- This version of the Shure Update Utility is compatible with the following other versions of software applications:
- Wireless Workbench 6.10.1
Software
6.1.104
28/07/2014
Ver todas las Actualizaciones
Important
SW 6000 v6.1.104 is compatibel to Firmware Release 7.5.0 or higher only.
New Features
- "Comment" data for a seat is exposed for displaying in the CDA
Bug Fixes
- Performance improvement in large systems
- Voting weight limits
- Licensing check might freeze the CUA
- Optimize Group Speech handling
- 'Alert on CDA' button only visible in CUA if configured
- Errror in ECA corrected
- Error when using AO and IS corrected
Software
6.10.1
10/07/2014
Ver todas las Actualizaciones
Improvements
- Resolved Mac installation issue that resulted in warning saying “Database not found”, and the application not launching.
Known Issues
- When scanning with AXT400 receivers, the Band Preset value in the Live Scan Settings dialog does not always stay in sync with the currently selected band of the receiver. The Band Preset can be manually changed to scan any supported range.
- When importing show files that contain a deployed frequency list, channels in that list with a custom equipment profile type will not be removed from the backups section of the Channel Summary dialog regardless of whether the custom profile is stored on the local machine's equipment profiles database. The calculator will not be able to coordinate frequencies until all channels are removed from the backups section for which there is not a custom equipment profile.
- Alerts logged when devices are first come online may list device parameters and their values as they are being discovered even though the parameter values themselves have not changed.
Notes
- In order to monitor and control networked devices, you must be connected to the same subnet. Cross-subnet connections to a network of gear are not supported.
- Tags that have been added to a show file but are not assigned to any devices are not saved within the show file.
- Opening show files created with older versions of Wireless Workbench may result in the Settings Conflicts dialog opening once the file has loaded. This is due to newly supported hardware parameters that have been introduced with updated firmware versions. To maintain all settings from the show file, select "Keep all settings from: Wireless Workbench".
- On machines running Windows 7, Wireless Workbench will not be able to discover devices when the machine has fallen back to its 169.254.xxx.yyy fallback IP address, regardless of the IP addressing of the connected Shure devices. To address this, perform one of the following:
- Insert a DHCP server onto your network and set your machine and Shure devices to accept automatic IP addressing.
- Statically assign your machine's IP address to the 169.254.xxx.yyy fallback subnet with a different IP address than the one it fell back to originally.
Software
6.10.0
25/06/2014
Ver todas las Actualizaciones
New Features
- Support for QLX-D Digital Wireless System
- Full networked control of the QLX-D receiver parameters
- Perform scans for the Coordination plot, Frequency plot, and RF History plot
- Coordinate and deploy frequencies to online and virtual QLX-D receivers
- Monitor receiver channels with channel strips and properties panels
- Monitor Only mode
- Prevent the software from making changes to any networked devices. Particularly useful during showtime, Monitor Only mode safeguards against accidental parameter changes.
- Select from Frequency List
- Browse and assign frequencies to online or virtual devices from a pre-coordinated frequency list.
- Accessible from the inventory view and properties panels of devices, Select from Frequency List allows convenient assignment of frequencies from Frequency Lists hosted by AXT600 Spectrum Managers, and Wireless Workbench.
Improvements
- Frequency Analysis has been completely redesigned.
- Found conflicts are listed for each frequency by type, and include details describing each conflict’s contributing factors.
- Optimization of conflicts reporting
- Only frequencies that are impacted by conflicts are marked as incompatible. Frequencies that have caused conflicts, but are not impacted themselves are no longer marked as incompatible.
- If you analyze solutions preformed with previous versions of Wireless Workbench 6, you may see different analysis results because of this optimization.
- Selection of both frequencies and conflicts highlight the frequencies that contribute to the respective conflicts.
- Conflicts are filterable from the results view by type.
- Conflict counts are displayed by type.
- Analysis report can be generated, printed, and exported to .csv or .pdf formats.
- ShowLink Properties Panel Enhancements
- Improved display of ShowLink Link Quality with inline icons for each connected transmitter.
- Added Channel Mask feature, allowing limits to be placed on which ShowLink channels are available for automatic selection.
- ULX-D Interference reported by the ULX-D receiver are now displayed in the Interference Events dialog.
- Battery meters for portable devices are now shown in segments instead of a gradient.
- Added TV data for Switzerland and Italy.
- Updated TV data for Germany and Australia.
- Added ShowLink Icon(s) to AXT400 channel strip when linked transmitter data is displayed.
- Added PSM900 band support for G6J, G14J, K1J, and L6J.
- Added PSM1000 band support for G10J, J8J, L8J, and L11J.
- Updated Group and Channel maps for AXT400 J bands G19, H18, J12, and L20.
Known Issues
- When scanning with AXT400 receivers, the Band Preset value in the Live Scan Settings dialog does not always stay in sync with the currently selected band of the receiver. The Band Preset can be manually changed to scan any supported range.
- When importing show files that contain a deployed frequency list, channels in that list with a custom equipment profile type will not be removed from the backups section of the Channel Summary dialog regardless of whether the custom profile is stored on the local machine's equipment profiles database. The calculator will not be able to coordinate frequencies until all channels are removed from the backups section for which there is not a custom equipment profile.
- Alerts logged when devices are first come online may list device parameters and their values as they are being discovered even though the parameter values themselves have not changed.
Notes
- In order to monitor and control networked devices, you must be connected to the same subnet. Cross-subnet connections to a network of gear are not supported.
- Tags that have been added to a show file but are not assigned to any devices are not saved within the show file.
- Opening show files created with older versions of Wireless Workbench may result in the Settings Conflicts dialog opening once the file has loaded. This is due to newly supported hardware parameters that have been introduced with updated firmware versions. To maintain all settings from the show file, select "Keep all settings from: Wireless Workbench".
- On machines running Windows 7, Wireless Workbench will not be able to discover devices when the machine has fallen back to its 169.254.xxx.yyy fallback IP address, regardless of the IP addressing of the connected Shure devices. To address this, perform one of the following:
- Insert a DHCP server onto your network and set your machine and Shure devices to accept automatic IP addressing.
- Statically assign your machine's IP address to the 169.254.xxx.yyy fallback subnet with a different IP address than the one it fell back to originally.
Firmware
1.5.6
25/06/2014
Ver todas las Actualizaciones
Important
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
New Features
- Interference Notifications for ULX-D are now displayed in Wireless Workbench 6.10 in the Interference Events dialog.
- ULX-D/QLX-D interoperability support. This release is required to support QLX-D transmitters. ULX-D receivers are compatible with QLX-D transmitters and will display QLXD1 or QLXD2 transmitter type given the following limitations
- QLX-D transmitters must be manually tuned to the same frequency as ULX-D receivers.
- Encryption must be disabled on both systems.
Improvements
- New Home Screen format displayed menu
- Simplified the ability to access and name both the Detailed per channel home screen and the ULXD4D/Q Summary screen by creating two separate menu structures.
Notes
- For operation of ULX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with ULX-D version 1.5.6:
- ULX-D ULXD1/2 Transmitters and ULXD4, ULXD4D, ULXD4Q Receivers 1.5.6
- Axient AXT400 Receivers and AXT600 Spectrum Managers 1.15.3
- Wireless Workbench 6 version 6.10.0
Firmware
1.5.6
25/06/2014
Ver todas las Actualizaciones
Important
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
New Features
- Interference Notifications for ULX-D are now displayed in Wireless Workbench 6.10 in the Interference Events dialog.
- ULX-D/QLX-D interoperability support. This release is required to support QLX-D transmitters. ULX-D receivers are compatible with QLX-D transmitters and will display QLXD1 or QLXD2 transmitter type given the following limitations
- QLX-D transmitters must be manually tuned to the same frequency as ULX-D receivers.
- ULX-D receivers cannot be in High Density mode (High Density mode is not available on QLX-D receivers)
- Encryption must be disabled on both systems.
Improvements
- New Home Screen format displayed menu
- Simplfied the ability to access and name both the Detailed per channel home screen and the ULXD4D/Q Summary screen by creating two separate menu structures.
Notes
- For operation of ULX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with ULX-D version 1.5.6:
- ULX-D ULXD1/2 Transmitters and ULXD4, ULXD4D, ULXD4Q Receivers 1.5.6
- Axient AXT400 Receivers and AXT600 Spectrum Managers 1.15.3
- Wireless Workbench 6 version 6.10.0
Firmware
1.5.6
25/06/2014
Ver todas las Actualizaciones
New Features
- Interference Notifications for ULX-D are now displayed in Wireless Workbench 6.10 in the Interference Events dialog.
- ULX-D/QLX-D interoperability support. This release is required to support QLX-D transmitters. ULX-D receivers are compatible with QLX-D transmitters and will display QLXD1 or QLXD2 transmitter type given the following limitations
- QLX-D transmitters must be manually tuned to the same frequency as ULX-D receivers.
- ULX-D receivers cannot be in High Density mode (High Density mode is not available on QLX-D receivers)
- Encryption must be disabled on both systems.
Notes
- After updating the ULXD4 Single Receiver from version 1.0.7, the user is required to reset the unit to Default Settings (DEVICE UTILITIES/SYSTEM RESET/RESTORE/DEFAULT SETTINGS).
- For operation of ULX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with ULX-D version 1.5.6:
- ULX-D ULXD1/2 Transmitters and ULXD4, ULXD4D, ULXD4Q Receivers 1.5.6
- Axient AXT400 Receivers and AXT600 Spectrum Managers 1.15.3
- Wireless Workbench 6 version 6.10.0