4.6.6

New Features

  • Disable USB Mute Sync communication with software codec platforms

Improvements

  • Improved gain, audio routing, and EQ contour settings when using the Designer “Optimize” feature with P300 and Shure microphones
  • Bug fixes

Known Issues

  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1+ firmware to use this feature
  • P300 Shure Audio Encryption sometimes has brief crackling sound on audio after muting
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.
  • P300 firmware periodically add new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of P300-IMX with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300-IMX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300-IMX with other Shure networked systems, reference the following list of minimum versions supported:
    • Designer 4.6.0
    • ANI22/ANI4IN/ANI4OUT 4.6.6
    • ANIUSB-MATRIX 4.6.7
    • MXA310 4.6.3
    • MXA910 4.6.6
    • MXA710 1.4.2
    • MXN5-C 1.4.3
    • MXA-MUTE 1.4.4
    • Microflex Wireless 9.0.4
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.17
Firmware
1.4.3

Improvements

  • Bug fixes

Known Issues

  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of MXN5-C with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • To operate this version of MXN5-C with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Designer 4.6.0
    • IntelliMix® Room 3.2.0
    • ANI22/ANI4IN/ANI4OUT 4.6.6
    • ANIUSB-MATRIX 4.6.7
    • MXA310 4.6.3
    • MXA910 4.6.6
    • MXA710 1.4.2
    • Microflex Wireless 9.0.4
    • P300 4.6.6
    • ULXD4D/4Q 2.5.0
    • SCM820 1.4.3
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.17
Firmware
1.4.4

Improvements

  • Bug fixes

Known Issues

  • When one Unmute/Mute LED light color is set to White at 100% Brightness while the other Unmute/Mute light is set to Off, it may cause the button to freeze or the device mute state to spontaneously change. Lowering the device LED brightness alleviates this issue.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of MXA-MUTE with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Designer 4.6.0
    • ANIUSB-MATRIX 4.6.7
    • MXA310 4.6.3
    • MXA910 4.6.6
    • MXA710 1.4.2
    • MXN5-C 1.4.3
    • P300 4.6.6
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.17
Firmware
4.6.7

New Features

  • Disable USB Mute Sync communication with software codec platforms

Improvements

  • Improved gain, audio routing, and EQ contour settings when using the Designer "Optimize" feature with ANIUSB and Shure microphones

Known Issues

  • Pop noise is triggered when the channel is unrouted in Dante controller with encryption enabled
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported.
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware or newer to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)
  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by reboot

Notes

  • User Guide
  • Command Strings
  • This version of ANIUSB-MATRIX is compatible with ANIUSB-MATRIX devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate this version of ANIUSB-MATRIX with Dante Controller, reference the following minimum versions
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of ANIUSB-MATRIX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of ANIUSB-MATRIX with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Designer 4.6.0
    • ANI22/ANI4IN/ANI4OUT 4.6.6
    • MXA310 4.6.3
    • MXA910 4.6.6
    • Microflex Wireless 9.0.4
    • P300 4.6.6
    • ULXD4D/4Q 2.5.0
    • SCM820 1.4.3
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.17
Firmware
4.6.6

Improvements

  • Bug fixes

Known Issues

  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by reboot
  • ANI22-XLR reverses absolute phase from Analog in to Dante out – workaround is to enable “Invert polarity” for Dante Output
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • This version of ANI22 is compatible with ANI22 devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate this version of ANI22 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of ANI22 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 4.6.6
    • ANI4OUT 4.6.6
    • ANIUSB-MATRIX 4.6.7
    • MXA310 4.6.3
    • MXA910 4.6.6
    • Microflex Wireless 9.0.4
    • ULXD4D/4Q 2.5.0
    • SCM820 1.4.3
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.17
Firmware
4.6.6

Improvements

  • Bug fixes

Known Issues

  • AES67 support is only available on UltimoX hardware
    • ANI4IN devices manufactured as of January 2018 are compatible with AES67
  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by reboot
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Network Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • This version of ANI4IN is compatible with ANI4IN devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate this version of ANI4IN with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • To operate this version of ANI4IN with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 4.6.6
    • ANI4OUT 4.6.6
    • ANIUSB-MATRIX 4.6.7
    • MXA310 4.6.3
    • MXA910 4.6.6
    • Microflex Wireless 9.0.4
    • P300 4.6.6
    • ULXD4D/4Q 2.5.0
    • SCM820 1.4.3
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.17
Firmware
4.6.6

Improvements

  • Bug fixes

Known Issues

  • AES67 support is only available on UltimoX hardware
    • ANI4IN devices manufactured as of January 2018 are compatible with AES67
  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by reboot
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Network Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • This version of ANI4IN is compatible with ANI4IN devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate this version of ANI4IN with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • To operate this version of ANI4IN with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 4.6.6
    • ANI4OUT 4.6.6
    • ANIUSB-MATRIX 4.6.7
    • MXA310 4.6.3
    • MXA910 4.6.6
    • Microflex Wireless 9.0.4
    • P300 4.6.6
    • ULXD4D/4Q 2.5.0
    • SCM820 1.4.3
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.17
Firmware
4.6.6

Improvements

  • Bug fixes

Known Issues

  • AES67 support is only available on UltimoX hardware
    • ANI4OUT devices manufactured as of January 2018 are compatible with AES67
  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by reboot
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Network Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • This version of ANI4OUT is compatible with ANI4OUT devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate this version of ANI4OUT with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • To operate this version of ANI4OUT with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 4.6.6
    • ANI4IN 4.6.6
    • ANIUSB-MATRIX 4.6.7
    • MXA310 4.6.3
    • MXA910 4.6.6
    • Microflex Wireless 9.0.4
    • P300 4.6.6
    • ULXD4D/4Q 2.5.0
    • SCM820 1.4.3
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.17
Firmware
4.6.6

Improvements

  • Bug fixes

Known Issues

  • AES67 support is only available on UltimoX hardware
    • ANI4OUT devices manufactured as of January 2018 are compatible with AES67
  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by reboot
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Network Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • This version of ANI4OUT is compatible with ANI4OUT devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate this version of ANI4OUT with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • To operate this version of ANI4OUT with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 4.6.6
    • ANI4IN 4.6.6
    • ANIUSB-MATRIX 4.6.7
    • MXA310 4.6.3
    • MXA910 4.6.6
    • Microflex Wireless 9.0.4
    • P300 4.6.6
    • ULXD4D/4Q 2.5.0
    • SCM820 1.4.3
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.17
App
2.4.0

Improvements