फर्मवेयर
AXT100 - Axient Bodypack Transmitter
संस्करणों
तिथि को प्रेषित
डाउनलोड
2.1.11
May 22, 2018
Improvements
- Support for new U.S. frequency bands:
- 578 MHz – 608 MHz (J5A)
- 653 MHz – 663 MHz (L3A)
Notes
- Transmitters used with receivers must be updated via IR. After the receiver is updated, go to the receiver menu: Tx > IRPresets > FWUpdate. Align the infrared ports with the transmitter and press Download.
- To operate Axient 2.1.11 devices with other Shure systems and software, see the following list of minimum versions:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULX-D ULXD4X Receivers 2.2.X
- QLX-D QLXD4 Receiver 2.2.11
- PSM1000 P10T Transmitter 1.5.12
- SBRC Shure Battery Rack Charger 1.0.1
- Shure Update Utility 2.4.2
- ShurePlus Channels 1.4.1
- Wireless Workbench 6.12.4
2.0.27
November 29, 2017
Improvements
- Bug fixes
Notes
- Transmitters to be used with receivers must be updated via IR. After the receiver is updated, go to the receiver menu: Tx > IRPresets > FWUpdate. Align the infrared ports with the transmitter and press Download.
- To operate Axient 2.0.27 devices with other Shure systems and software, see the following list of minimum versions:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULX-D ULXD4X Receivers 2.1.16
- QLX-D QLXD4 Receiver 2.1.5
- PSM1000 P10T Transmitter 1.4.2
- SBRC Shure Battery Rack Charger 1.0.1
- Shure Update Utility 2.4.1
- ShurePlus Channels 1.4
- Wireless Workbench 6.12.2
1.17.10
December 1, 2016
RECOMMENDATION
Update all Axient devices in a configuration to the same firmware version.
NEW FEATURES
- RF Mute added to the Power Indicator LED
- Factory reset
IMPROVEMENTS
- Updated AXT910/AXT920 fuel gauge errors
- Added ability to send Talk Switch controls with the UHF audio carrier.
NOTES
- Transmitters to be used with receivers must be updated via IR. After the receiver is updated, go to the receiver menu: Tx > IRPresets > FWUpdate. Align the infrared ports with the transmitter and press Download.
- For operation of Axient devices with other Shure networked systems, see the following list of minimum versions that are supported with Axient version 1.17.10:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4X ULX-D Receivers 2.0.19
- QLXD4 QLX-D Receiver 1.1.15
- P10T PSM1000 Transmitter 1.4.2
- Wireless Workbench 6.12
1.16.11
November 17, 2015
NEW FEATURES
- Option added for configuring the power button as a trigger of Talk Switch.
NOTES
- Transmitters to be used with receivers must be updated via IR. After the receiver is updated, go to the receiver menu: Tx > IRPresets > FWUpdate. Align the infrared ports with the transmitter and press Download.
- For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.16.11:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4X ULX-D Receivers 1.6.11
- QLXD4 QLX-D Receiver 1.1.15
- P10T PSM1000 Transmitter 1.3.9
- Wireless Workbench 6.11.3
1.15.3
June 25, 2014
NOTES
- For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.15.3:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4x ULX-D Receivers 1.5.6
- QLXD4 QLX-D Receiver 1.0.13
- P10T PSM1000 Transmitter 1.3.9
- Wireless Workbench 6.10.0
1.14.6
January 24, 2014
NEW FEATURES
Hardware Identify trigger
- The trigger for Hardware Identify of AXT100 in WWB6 is a 1-second press and hold of the Set button on AXT100 when they are linked, online and at the root home screen.
NOTES
- For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.14.6:
- UR4 1.171
- UR3 1.0.0.16
- UR5 1.0.0.13
- ULXD4 ULXD Receiver 1.4.14
- P10T 1.3.9
- Wireless Workbench 6.9.
1.13.5
July 15, 2013
Release Date: 7/15/2013
NOTES
- For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.12.8:
- UR4 UHF-R receiver 1.166
- UR3 Plug-on Transmitter 1.0.0.9
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4 ULXD Receiver 1.2.14
- P10T PSM1000 Transmitter 1.3.4
- Wireless Workbench 6 Beta version 6.8.0
1.12.8
May 2, 2013
IMPROVEMENTS
- New models for transmitter frequency bands
- G7C, G19, H18, J12, L20, R16
- AXT400C receiver supports new transmitter frequency band: R16
NOTES
- For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.12.8:
- UR4 UHF-R receiver 1.166
- UR3 Plug-on Transmitter 1.0.0.9
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4 ULXD Receiver 1.2.14
- P10T PSM1000 Transmitter 1.3.4
- Wireless Workbench 6 Beta version 6.6.1
1.11.14
March 21, 2013
NEW FEATURES
- Hardware Identification in WWB6
- Enables the user to trigger a flashing sequence from the physical device to locate the Wireless Workbench 6 representation of that device in the software.
- To engage, quickly tap the power button on the transmitter.
IMPROVEMENTS
- AXT400 B receiver supports new transmitter bands including J5HK, G12, and H12
NOTES
- For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.11.14:
- UR4 UHF-R receiver 1.166
- UR3 Plug-on Transmitter 1.0.0.9
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4 ULXD Receiver 1.2.14
- P10T PSM1000 Transmitter 1.3.4
- Wireless Workbench 6 Beta version 6.6.0
1.10.2
October 3, 2012
NEW FEATURES
- Transmitter Overload indicator
- Indication from the transmitter is available via ShowLink when the audio input circuitry is overloaded. Previously displayed only on the transmitter, this alert now appears on the AXT400 front panel display and is available in Wireless Workbench 6 monitoring views when the transmitter is online.
IMPROVEMENTS
- Confirmation for interference-prompted frequency switches when transmitter is offline
- Additional prompt to avoid unintentionally changing frequency when a linked transmitter is not online to follow the change
NOTES
- For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.10.2:
- UR4 UHF-R receiver 1.166
- UR3 Plug-on Transmitter 1.0.0.9
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4 ULXD Receiver 1.2.14
- P10T PSM1000 Transmitter 1.3.4
- Wireless Workbench 6 Beta version 6.5.0
1.9.2
July 9, 2012
IMPROVEMENTS
- Improved ShowLink connectivity in environments with high Wi Fi activity
- Transmitter remote control link is maintained under higher ratios of Wi Fi traffic to ShowLink messages, resulting in fewer instances of transmitters falling offline.
NOTES
- For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.9.2:
- UR4 UHF-R receiver 1.166
- UR3 Plug-on Transmitter 1.0.0.9
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4 ULXD Receiver 1.2.14
- P10T PSM1000 Transmitter 1.3.4
- Wireless Workbench 6 Beta version 6.4.0
1.8.8
April 2, 2012
NEW FEATURES
- Support for the following Axient transmitter frequency Bands: MA24, G1E, H4E, J5E, MJBX, K4E, L3E, M8, P8, P9, Q5
- Axient transmitters now support custom groups.
- Axient and UHF-R transmitters can get Custom Groups from the AXT400 receiver via IR Sync (from AXT400 menu select Tx>IR Presets>CG, select ‘Sync Custom Groups’ and then IR Sync the transmitter).
NOTES
- Transmitters to be used with receivers must be updated via IR. After updating the receiver, select Tx>IR Presets>FW Update from the receiver menu and align the infrared ports with the transmitter before selecting ‘Download’.
- For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.8.8:
- UR4 UHF-R receiver - 1.166
- UR3 Plug-on Transmitter - 1.0.0.9
- UR5 Portable Diversity Receiver - 1.0.0.13
- ULXD4 ULXD Receiver - 1.0.3
- P10T PSM1000 Transmitter - 1.3.4
- Wireless Workbench - 6.3.1 Beta
1.7.5
January 24, 2012
NOTES
- Transmitters to be used with receivers must be updated via IR. After updating the receiver, select Tx > IR Presets > FW Update from the receiver menu and align the infrared ports with the transmitter before selecting ‘Download’.
- For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.7.5:
- UR4 UHF-R receiver 1.166
- UR3 Plug-on Transmitter 1.0.0.9
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4 ULXD Receiver 1.0.3
- P10T PSM1000 Transmitter 1.3.1 Beta
- Wireless Workbench 6.2.1.34 Beta
एसोसिएटेड उत्पाद
AXT100
वायरलेस बॉडीपैक ट्रांसमीटर अधिक चैनलों के लिए ऑन-एयर और शानदार ऑडियो गुणवत्ता के लिए अल्ट्रा-लीनियर आरएफ प्रदर्शन प्रदान करता है।