Firmware

AXT100 - Axient Bodypack Transmitter

Versions

Date Posted

Scarica

2.1.11
May 22, 2018

Improvements

  • Support for new U.S. frequency bands:
    • 578 MHz – 608 MHz (J5A)
    • 653 MHz – 663 MHz (L3A)

Notes

  • Transmitters used with receivers must be updated via IR. After the receiver is updated, go to the receiver menu: Tx > IRPresets > FWUpdate. Align the infrared ports with the transmitter and press Download.
  • To operate Axient 2.1.11 devices with other Shure systems and software, see the following list of minimum versions:
    • UR4 UHF-R receiver 1.171
    • UR3 Plug-on Transmitter 1.0.0.16
    • UR5 Portable Diversity Receiver 1.0.0.13
    • ULX-D ULXD4X Receivers 2.2.X
    • QLX-D QLXD4 Receiver 2.2.11
    • PSM1000 P10T Transmitter 1.5.12
    • SBRC Shure Battery Rack Charger 1.0.1
    • Shure Update Utility 2.4.2
    • ShurePlus Channels 1.4.1
    • Wireless Workbench 6.12.4
2.0.27
November 29, 2017

Improvements

  • Bug fixes

Notes

  • Transmitters to be used with receivers must be updated via IR. After the receiver is updated, go to the receiver menu: Tx > IRPresets > FWUpdate. Align the infrared ports with the transmitter and press Download.
  • To operate Axient 2.0.27 devices with other Shure systems and software, see the following list of minimum versions:
    • UR4 UHF-R receiver 1.171
    • UR3 Plug-on Transmitter 1.0.0.16
    • UR5 Portable Diversity Receiver 1.0.0.13
    • ULX-D ULXD4X Receivers 2.1.16
    • QLX-D QLXD4 Receiver 2.1.5
    • PSM1000 P10T Transmitter 1.4.2
    • SBRC Shure Battery Rack Charger 1.0.1
    • Shure Update Utility 2.4.1
    • ShurePlus Channels 1.4
    • Wireless Workbench 6.12.2
1.17.10
December 1, 2016

RECOMMENDATION

Update all Axient devices in a configuration to the same firmware version.

NEW FEATURES

  • RF Mute added to the Power Indicator LED
  • Factory reset

IMPROVEMENTS

  • Updated AXT910/AXT920 fuel gauge errors
  • Added ability to send Talk Switch controls with the UHF audio carrier.

NOTES

  • Transmitters to be used with receivers must be updated via IR. After the receiver is updated, go to the receiver menu: Tx > IRPresets > FWUpdate. Align the infrared ports with the transmitter and press Download.
  • For operation of Axient devices with other Shure networked systems, see the following list of minimum versions that are supported with Axient version 1.17.10:
    • UR4 UHF-R receiver 1.171
    • UR3 Plug-on Transmitter 1.0.0.16
    • UR5 Portable Diversity Receiver 1.0.0.13
    • ULXD4X ULX-D Receivers 2.0.19
    • QLXD4 QLX-D Receiver 1.1.15
    • P10T PSM1000 Transmitter 1.4.2
    • Wireless Workbench 6.12
1.16.11
November 17, 2015

NEW FEATURES

  • Option added for configuring the power button as a trigger of Talk Switch.

NOTES

  • Transmitters to be used with receivers must be updated via IR. After the receiver is updated, go to the receiver menu: Tx > IRPresets > FWUpdate. Align the infrared ports with the transmitter and press Download.
  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.16.11:
    • UR4 UHF-R receiver 1.171
    • UR3 Plug-on Transmitter 1.0.0.16
    • UR5 Portable Diversity Receiver 1.0.0.13
    • ULXD4X ULX-D Receivers 1.6.11
    • QLXD4 QLX-D Receiver 1.1.15
    • P10T PSM1000 Transmitter 1.3.9
    • Wireless Workbench 6.11.3
1.15.3
June 25, 2014

NOTES

  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.15.3:
    • UR4 UHF-R receiver 1.171
    • UR3 Plug-on Transmitter 1.0.0.16
    • UR5 Portable Diversity Receiver 1.0.0.13
    • ULXD4x ULX-D Receivers 1.5.6
    • QLXD4 QLX-D Receiver 1.0.13
    • P10T PSM1000 Transmitter 1.3.9
    • Wireless Workbench 6.10.0
1.14.6
January 24, 2014

NEW FEATURES

Hardware Identify trigger

  • The trigger for Hardware Identify of AXT100 in WWB6 is a 1-second press and hold of the Set button on AXT100 when they are linked, online and at the root home screen.

NOTES

  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.14.6:
    • UR4 1.171
    • UR3 1.0.0.16
    • UR5 1.0.0.13
    • ULXD4 ULXD Receiver 1.4.14
    • P10T 1.3.9
    • Wireless Workbench 6.9.
1.13.5
July 15, 2013

Release Date: 7/15/2013

NOTES

  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.12.8:
    • UR4 UHF-R receiver 1.166
    • UR3 Plug-on Transmitter 1.0.0.9
    • UR5 Portable Diversity Receiver 1.0.0.13
    • ULXD4 ULXD Receiver 1.2.14
    • P10T PSM1000 Transmitter 1.3.4
    • Wireless Workbench 6 Beta version 6.8.0
1.12.8
May 2, 2013

IMPROVEMENTS

  • New models for transmitter frequency bands
    • G7C, G19, H18, J12, L20, R16
  • AXT400C receiver supports new transmitter frequency band: R16

NOTES

  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.12.8:
    • UR4 UHF-R receiver 1.166
    • UR3 Plug-on Transmitter 1.0.0.9
    • UR5 Portable Diversity Receiver 1.0.0.13
    • ULXD4 ULXD Receiver 1.2.14
    • P10T PSM1000 Transmitter 1.3.4
    • Wireless Workbench 6 Beta version 6.6.1
1.11.14
March 21, 2013

NEW FEATURES

  • Hardware Identification in WWB6
    • Enables the user to trigger a flashing sequence from the physical device to locate the Wireless Workbench 6 representation of that device in the software.
    • To engage, quickly tap the power button on the transmitter.

IMPROVEMENTS

  • AXT400 B receiver supports new transmitter bands including J5HK, G12, and H12

NOTES

  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.11.14:
    • UR4 UHF-R receiver 1.166
    • UR3 Plug-on Transmitter 1.0.0.9
    • UR5 Portable Diversity Receiver 1.0.0.13
    • ULXD4 ULXD Receiver 1.2.14
    • P10T PSM1000 Transmitter 1.3.4
    • Wireless Workbench 6 Beta version 6.6.0
1.10.2
October 3, 2012

NEW FEATURES

  • Transmitter Overload indicator
    • Indication from the transmitter is available via ShowLink when the audio input circuitry is overloaded. Previously displayed only on the transmitter, this alert now appears on the AXT400 front panel display and is available in Wireless Workbench 6 monitoring views when the transmitter is online.

IMPROVEMENTS

  • Confirmation for interference-prompted frequency switches when transmitter is offline
    • Additional prompt to avoid unintentionally changing frequency when a linked transmitter is not online to follow the change

NOTES

  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.10.2:
    • UR4 UHF-R receiver 1.166
    • UR3 Plug-on Transmitter 1.0.0.9
    • UR5 Portable Diversity Receiver 1.0.0.13
    • ULXD4 ULXD Receiver 1.2.14
    • P10T PSM1000 Transmitter 1.3.4
    • Wireless Workbench 6 Beta version 6.5.0
1.9.2
July 9, 2012

IMPROVEMENTS

  • Improved ShowLink connectivity in environments with high Wi Fi activity
    • Transmitter remote control link is maintained under higher ratios of Wi Fi traffic to ShowLink messages, resulting in fewer instances of transmitters falling offline.

NOTES

  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.9.2:
    • UR4 UHF-R receiver 1.166
    • UR3 Plug-on Transmitter 1.0.0.9
    • UR5 Portable Diversity Receiver 1.0.0.13
    • ULXD4 ULXD Receiver 1.2.14
    • P10T PSM1000 Transmitter 1.3.4
    • Wireless Workbench 6 Beta version 6.4.0
1.8.8
April 2, 2012

NEW FEATURES

  • Support for the following Axient transmitter frequency Bands: MA24, G1E, H4E, J5E, MJBX, K4E, L3E, M8, P8, P9, Q5
  • Axient transmitters now support custom groups.
  • Axient and UHF-R transmitters can get Custom Groups from the AXT400 receiver via IR Sync (from AXT400 menu select Tx>IR Presets>CG, select ‘Sync Custom Groups’ and then IR Sync the transmitter).

NOTES

  • Transmitters to be used with receivers must be updated via IR. After updating the receiver, select Tx>IR Presets>FW Update from the receiver menu and align the infrared ports with the transmitter before selecting ‘Download’.
  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.8.8:
    • UR4 UHF-R receiver - 1.166
    • UR3 Plug-on Transmitter - 1.0.0.9
    • UR5 Portable Diversity Receiver - 1.0.0.13
    • ULXD4 ULXD Receiver - 1.0.3
    • P10T PSM1000 Transmitter - 1.3.4
    • Wireless Workbench - 6.3.1 Beta
1.7.5
January 24, 2012

NOTES

  • Transmitters to be used with receivers must be updated via IR. After updating the receiver, select Tx > IR Presets > FW Update from the receiver menu and align the infrared ports with the transmitter before selecting ‘Download’.
  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.7.5:
    • UR4 UHF-R receiver 1.166
    • UR3 Plug-on Transmitter 1.0.0.9
    • UR5 Portable Diversity Receiver 1.0.0.13
    • ULXD4 ULXD Receiver 1.0.3
    • P10T PSM1000 Transmitter 1.3.1 Beta
    • Wireless Workbench 6.2.1.34 Beta

Associated products

AXT100

Unendo le caratteristiche più avanzate alle prestazioni elevate, il trasmettitore bodypack Shure Axient AXT100 è un grande balzo in avanti della tecnologia radiomicrofonica.