Downloads

Software & Firmware Archives

Filter by update type

Type

Release Title

Latest Version

Associated Products

Scarica

App
1.8.2

Important

  • Shure is currently looking into an issue with iOS 16 compatibility. Some functions may not work as expected.

Known Issues

  • The FPS and resolution combinations available for selection will vary based on the user’s phone.
  • If you monitor your recordings with Bluetooth earphones, you may hear artifacts, such as noise, while monitoring. If this occurs, we recommend changing the sample rate of your recordings. Some products may produce artifacts at 44.1 kHz, while others may do so for 48 kHz recordings. Please keep in mind that even if you hear artifacts while monitoring, they will not be present in the recordings themselves.

Notes

Firmware
1.5.15

Improvements

  • General enhancements

Known Issues

  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of MXA710 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • To operate this version of MXA710 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.0
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.17
    • MXA310 4.7.8
    • MXA910 4.7.13
    • MXN5-C 1.5.12
    • MXA-MUTE 1.5.16
    • Microflex Wireless 10.0.6
    • P300 4.7.17
    • ULXD4D/4Q 2.6.3
    • SCM820 1.4.3
    • Shure Update Utility 2.7.2
    • Shure Web Device Discovery 1.2.17
Firmware
1.5.15

Improvements

  • General enhancements

Known Issues

  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of MXA710 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (Mac OS X)
  • To operate this version of MXA710 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.0
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.17
    • MXA310 4.7.8
    • MXA910 4.7.13
    • MXN5-C 1.5.12
    • MXA-MUTE 1.5.16
    • Microflex Wireless 10.0.6
    • P300 4.7.17
    • ULXD4D/4Q 2.6.3
    • SCM820 1.4.3
    • Shure Update Utility 2.7.2
    • Shure Web Device Discovery 1.2.17
Software
4.7.2

Important

  • New licenses are no longer being offered. For maintenance licenses, please contact your local Shure representative.

Bug Fixes

  • LDAP server configuration validation for port 636; password and username validation for port 389 errors during upgrade from SystemOn version 4.6.0 to 4.7.0

Pre-Upgrade Requirements

  • Designer and SystemOn cannot be installed on the same computer
  • Internet access is no longer required during the installation process; however, use of certain features like firmware updating and text notifications require internet access
  • After upgrading SystemOn, clear your browser cache on the device accessing the SystemOn server, then re-assign your licenses to your devices by navigating to your organization > Licenses > Start managing
  • SystemOn and Designer applications cannot be installed on the same computer; do not attempt to install one over the other
  • Before updating firmware, turn off “Device Missing” notifications, then turn them back on after completing the firmware updates

Platform Requirements

  • Supported Operating Systems
    • Windows Server 2019
    • Windows 10 (Professional or Enterprise), 64-bit edition
  • Supported Web Browsers
    • Chrome
    • Safari
    • Windows Edge
  • Hardware Minimum Requirements
    • 8 GB RAM (16 GB may be required when hundreds of devices are being accessed)
    • 2 GB hard disk
    • i5 dual-core processor

Notes

  • User Guide
  • To update firmware, please download Shure Update Utility
  • This version of SystemOn is compatible with the following recommended software and firmware versions:
    • IntelliMix Room 3.3.0
    • ANIUSB-MATRIX 4.7.16
    • MXA310 4.7.8
    • MXA710 1.5.15
    • MXA910 4.7.13
    • MXA920 1.3.276
    • MXA-MUTE 1.5.16
    • MXN5-C 1.5.12
    • Microflex Wireless 10.0.6
    • P300 4.7.17
    • SBC220/240 1.3.45
    • SBC250/450/850 2.6.3
    • SCM820 1.4.3
    • ULX-D 2.6.3
Firmware
2.5.0

Overview

This update is the result of extensive measurement and calibration in our certified acoustic labs at the Shure headquarters. It introduces significantly improved clarity, more consistent speech levels, and enhanced intelligibility for a more natural and transparent communication experience. 

Improvements

  • Improved echo cancellation, providing enhanced double-talk performance for better interaction between conference sites and an overall better experience for meeting participants
  • System sounds, such as push-button chime level, were also reduced for a more pleasant experience
  • Readjusted pickup pattern on Ceiling to better match Narrow, Medium, and Wide beam selections
Firmware
10.0.7

These release notes cover the following models: 

  • MXWAPT2/4/8 Access Point Transceivers

Important

  • Update any MXW devices which are below the minimum supported firmware 8.0.3 by using the Shure Update Utility (SUU) found here.  Please note – should the firmware version used be older than 5.2.2, it is advised to upgrade to version 5.2.2 first before updating to any subsequent more recent releases. Close the SUU when complete.

Improvements

  • Support for added hardware revisions

Known Issues

  • Multiple Primary Leader Clocks in Dante Controller might appear with mix of AES67 enabled on an MXW-APT as well as an Axient-Digital system on the same subnet

Notes

  • User Guide
  • Quick Start Guide
  • Crestron/AMX Control Strings
  • To operate this version of MXW with other Shure networked systems, see the following list of recommended software and firmware versions:
    • SCM820 1.4.3
    • Shure Web Device Discovery 1.2.17
    • Shure Update Utility 2.7.2
    • SystemOn 4.7.2
Firmware
10.0.7

These release notes cover the following models: 

  • MXWAPT2/4/8 Access Point Transceivers

Important

  • Update any MXW devices which are below the minimum supported firmware 8.0.3 by using the Shure Update Utility (SUU) found here.  Please note – should the firmware version used be older than 5.2.2, it is advised to upgrade to version 5.2.2 first before updating to any subsequent more recent releases. Close the SUU when complete.

Improvements

  • Support for added hardware revisions

Known Issues

  • Multiple Primary Leader Clocks in Dante Controller might appear with mix of AES67 enabled on an MXW-APT as well as an Axient-Digital system on the same subnet

Notes

  • User Guide
  • Quick Start Guide
  • Crestron/AMX Control Strings
  • To operate this version of MXW with other Shure networked systems, see the following list of recommended software and firmware versions:
    • SCM820 1.4.3
    • Shure Web Device Discovery 1.2.17
    • Shure Update Utility 2.7.2
    • SystemOn 4.7.2
Firmware
10.0.7

These release notes cover the following models: 

  • MXWAPT2/4/8 Access Point Transceivers

Important

  • Update any MXW devices which are below the minimum supported firmware 8.0.3 by using the Shure Update Utility (SUU) found here.  Please note – should the firmware version used be older than 5.2.2, it is advised to upgrade to version 5.2.2 first before updating to any subsequent more recent releases. Close the SUU when complete.

Improvements

  • Support for added hardware revisions

Known Issues

  • Multiple Primary Leader Clocks in Dante Controller might appear with mix of AES67 enabled on an MXW-APT as well as an Axient-Digital system on the same subnet

Notes

  • User Guide
  • Quick Start Guide
  • Crestron/AMX Control Strings
  • To operate this version of MXW with other Shure networked systems, see the following list of recommended software and firmware versions:
    • SCM820 1.4.3
    • Shure Web Device Discovery 1.2.17
    • Shure Update Utility 2.7.2
    • SystemOn 4.7.2
Firmware
2.5.2

Recommendation

  • Update all QLX-D devices in a configuration to the same firmware version.

Important

  • QLX-D 2.X firmware versions are incompatible with 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Support for added hardware revisions

Notes

  • To operate QLX-D transmitters with ULX-D receivers and ULX-D transmitters with QLX-D receivers, all devices must be on version 2.X firmware or later.
  • To operate this version of QLX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • AXT600 Axient Spectrum Manager 2.1.41
    • PSM1000 P10T Transmitters 1.3.6
    • ULX-D 2.6.3
    • Wireless Workbench 6.15.0
    • Shure Update Utility 2.7.2
    • ShurePlus Channels iOS 1.5.2
    • ShurePlus Channels Android 1.1.1
Firmware
2.5.2

Recommendation

  • Update all QLX-D devices in a configuration to the same firmware version.

Important

  • QLX-D 2.X firmware versions are incompatible with 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Support for added hardware revisions

Notes

  • To operate QLX-D transmitters with ULX-D receivers and ULX-D transmitters with QLX-D receivers, all devices must be on version 2.X firmware or later.
  • To operate this version of QLX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • AXT600 Axient Spectrum Manager 2.1.41
    • PSM1000 P10T Transmitters 1.3.6
    • ULX-D 2.6.3
    • Wireless Workbench 6.15.0
    • Shure Update Utility 2.7.2
    • ShurePlus Channels iOS 1.5.2
    • ShurePlus Channels Android 1.1.1