Downloads
Archiwum oprogramowania i firmware
Firmware
1.7.34
December 10, 2015
Zobacz wszystkie aktualizacje
Recommendation
Update all ULX-D devices in a configuration to the same firmware version
Improvement
- Added new frequency band Z16 (1240 – 1260 MHz) for Japan
Notes
- Fixed bug relating to encryption mismatch conditions.
- Fixed IR LED behavior when firmware updating transmitters.
- Transmitters to be used with receivers must be updated via IR. After the receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER.
- For operation of ULX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with ULX-D version 1.7.34:
- QLX-D receiver 1.0.15
Firmware
1.7.34
December 10, 2015
Zobacz wszystkie aktualizacje
Improvement
- Added new frequency band Z16 (1240 – 1260 MHz) for Japan
Notes
- Fixed bug relating to encryption mismatch conditions.
- Fixed IR LED behavior when firmware updating transmitters.
- Transmitters to be used with receivers must be updated via IR. After the receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER.
- For operation of ULX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with ULX-D version 1.7.34:
- QLX-D receiver 1.0.15
Firmware
1.7.34
December 10, 2015
Zobacz wszystkie aktualizacje
Important
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
Improvements
- Added new frequency band Z16 (1240 – 1260 MHz) for Japan
Notes
- Fixed bug relating to encryption mismatch conditions.
- Fixed IR LED behavior when firmware updating transmitters.
- Transmitters to be used with receivers must be updated via IR. After the receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER.
- For operation of ULX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with ULX-D version 1.7.34:
- QLX-D receiver 1.0.15