Firmware
1.3.26

Recommendation

  • Update all Axient Digital devices in a configuration to the same firmware version.

Improvements

  • Added TPCI Commands for Dante Device and Channel Names
  • Bug fixes

Notes

  • User Guide
  • Command Strings
  • To operate AD4D version 1.3.26 devices with other Shure systems and software, see the following list of minimum versions:
    • Axient Digital AD1/2, ADX1/1M/2/2FD and AD3 Transmitters 1.3.26
    • Axient Digital AD4D/Q Receivers 1.3.26
    • Axient AXT600 Spectrum Manager 2.1.38
    • SBRC Shure Battery Rack Charger 1.1.6
    • Shure Update Utility 2.6.1
    • Wireless Workbench 6.14.1
    • ShurePlus Channels iOS 1.4.6
    • ShurePlus Channels Android (Beta) 1.0.1
Firmware
2.2.2

Improvements

  • Updated Error Message for text fields
  • Enhanced audio quality and performance
  • Resolved UI issues in cases when Organization password is not set
  • Prevent self-test from running while devices are in use
Firmware
2.5.0

Improvements

  • NEW TCPI command for SBC250/SBC450/SBC850:
    • FW_VER - Firmware version of docked microphone

Notes 

  • SBC250 User Guide
  • SBC450/850 User Guide
  • To set up ULXD6/8 transmitters to receive firmware updates while docked in SBC250/450/850 Networked Charging Stations, follow these steps:
    1. Place transmitters on a charging station and ensure the charging station is connected to the network.
    2. Launch Shure Update Utility to find firmware updates.
    3. Download updates and select Send Updates.
  • To operate SBC250/450/850 version 2.5.0 with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
    • QLX-D QLXD4 Receivers 2.3.24
    • Wireless Workbench 6.14.1
    • Shure Update Utility 2.6.1
    • ShurePlus Channels 1.4.6
Firmware
2.5.0

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Notes

  • User Guide
  • To update firmware for ULXD6/8 transmitters with ULX-D or QLX-D receivers:
    1. Update receivers to the following minimum versions:
      • ULXD4, ULXD4D, and ULXD4Q Receivers 2.1.16 or higher
      • QLXD4 Receivers 2.1.5 or higher
    2. Using Shure Update Utility, download ULXD6/8 transmitter firmware to the receivers.
    3. Using the FW Update menu on a receiver, update transmitters.
  • To update ULXD6/8 transmitters firmware while they are docked in an SBC250/450/850 Networked Charging Station:
    1. Place transmitters on charging station and ensure charging station is connected to the network.
    2. Launch Shure Update Utility to find firmware updates.
    3. Download updates and select Send Updates.
  • To operate ULXD6/8 version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
    • SBC250/450/850 Networked Charging Stations 2.5.0
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.24
    • Wireless Workbench 6.14.1
    • Shure Update Utility 2.6.1
    • ShurePlus Channels 1.4.6
Firmware
2.5.0

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
  • ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
  • ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
  • After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.

Improvements

  • NEW TCPI commands for ULXD4/ULXD4D/ULXD4Q:
    • MODEL - Name of the receiver model
    • TX_FW - Firmware version of the received transmitter
  • Support added for new ULXD4D/Q devices which ensure that encryption is used
    • At this time, AXT600 Spectrum Manager does not support always encryption DCID

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
    • SBC250/450/850 Networked Charging Stations 2.4.13
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.14.1
    • Shure Update Utility 2.6.1
    • ShurePlus Channels 1.4.6
Firmware
2.5.0

Important

  • ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
  • ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
  • After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • NEW TCPI commands for ULXD4/ULXD4D/ULXD4Q:
    • MODEL - Name of the receiver model
    • TX_FW - Firmware version of the received transmitter
  • Support added for new ULXD4D/Q devices which ensure that encryption is used
    • At this time, AXT600 Spectrum Manager does not support always encryption DCID

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
    • SBC250/450/850 Networked Charging Stations 2.4.13
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.14.1
    • Shure Update Utility 2.6.1
    • ShurePlus Channels 1.4.6
Firmware
2.5.0

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • NEW TCPI commands for ULXD4/ULXD4D/ULXD4Q:
    • MODEL - Name of the receiver model
    • TX_FW - Firmware version of the received transmitter
  • Support added for new ULXD4D/Q devices which ensure that encryption is used
    • At this time, AXT600 Spectrum Manager does not support always encryption DCID

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
    • SBC250/450/850 Networked Charging Stations 2.4.13
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.14.1
    • Shure Update Utility 2.6.1
    • ShurePlus Channels 1.4.6
Firmware
2.5.0

Notes

  • User Guide
  • To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD4/4D/4Q Receivers 2.5.0
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.24
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.14.1
    • Shure Update Utility 2.6.1
    • ShurePlus Channels 1.4.6
Firmware
9.3.0

Release notes cover the following models:

  • MXC605/605-F
  • MXC615
  • MXC620/620-F
  • MXC630/630-F
  • MXC640
  • MXCIC
  • MXCMIU
  • MXCSIGN
  • DIS-CCU
  • AO6004
  • DC5900F
  • DC5980P
  • DCS6000 legacy conference and interpreter units

Important

  • This firmware release can be used to update Microflex Complete (MXC) or DCS 6000 systems using DIS-CCU Central Unit and to update DC5900F and DC5980P devices to register and work in an MXC system.
  • Systems using CU 5905, CU 6000, CU 6005, CU 6010, CU 6011, CU 6105, or CU 6110 Central Units are not supported in this release.
  • The Firmware Update Utility (FUU) included in this release, is required to be used making the update.

New Features

  • MXC640
    • Optimization of voting performance (card insert/remove):
      • When the participant inserts the card, an animation 'Reading NFC card' is shown following with displaying of the name of the participant logging in. The animation is still shown when a participant is logging in, when a voting session is not started, but is fast-forwarded and greeting-banner removed, when a voting session is started enabling the participant to vote as quick as possible after inserting the card.
  • DIS-CCU
    • ‘System information’ report updated to include firmware version of devices
    • Chairman' changed to 'Chairperson'

Bug Fixes

  • DIS-CCU
    • The FW version number reported with the 'avr' command is different compared to FW version reported in FUU
    • Event log warning added if unknown card is detected
  • MXC640
    • Removal of wrong NFC card during SW6000 meeting & voting, results in card-error-animation hang
    • Wrong voting conclusion (passed/not passed) can be displayed when under SW6000 control

Notes

  • MXC and DCS 6000 firmware files are packaged together in the same release file.
  • To operate MXC devices with FW release 9.3.0 with other Shure networked systems, see the following list of minimum software and firmware versions:
    • SW6000 v9.2 or later
    • Shure NFC Programming App 1.0.3
Firmware
9.2.3

Release notes cover the following models:

  • MXC605/605-F
  • MXC615
  • MXC620/620-F
  • MXC630/630-F
  • MXC640
  • MXCIC
  • MXCMIU
  • MXCSIGN
  • DIS-CCU
  • AO6004
  • DC5900F
  • DC5980P
  • DCS6000 legacy conference and interpreter units

Important

  • This firmware release can be used to update Microflex Complete (MXC) or DCS 6000 systems using DIS-CCU Central Unit and to update DC5900F and DC5980P to register and work in an MXC system.
  • Systems using CU 5905, CU 6000, CU 6005, CU 6010, CU 6011, CU 6105, or CU 6110 Central Units are not supported in this release.
  • The Firmware Update Utility (FUU) included in this release, is required to be used making the update.

New Features

  • This is a hotfix and does not include any new features. Please refer to ‘Release Note 9.2.0’ for a list of new features in FW 9.2.

Bug Fixes

  • MXC620/620-F, MXC630/630-F, MXC640
    • A bug is corrected, where the NFC card, art. no. ‘MXCNFCCard-10PK’, did not work in the units.
  • MXCIC
    • A bug is corrected, where units randomly did not respond to system changes (language channels etc.) and where the microphone list was not shown.

Known Issues

  • For a list of known issues please refer to ‘Release Note 9.2.0’ for a list of new features in FW 9.2.

Notes

  • MXC and DCS 6000 firmware files are packaged together in the same release file.
  • To operate MXC devices with FW release 9.2 with other Shure networked systems, see the following list of minimum software and firmware versions:
    • SW6000 v9.2 or v9.3
    • Shure NFC Programming App 1.0.3