Downloads
Archiwum oprogramowania i firmware
Firmware
2.3.34
May 10, 2019
Zobacz wszystkie aktualizacje
Important
- Before ULX-D and QLX-D receivers can host or update ULXD6/8 firmware, they must be updated to the following minimum firmware versions:
- ULXD4, ULXD4D, and ULXD4Q Receivers 2.1.16 or higher
- QLXD4 Receivers 2.1.5 or higher
- New hardware revisions with the ULX-D 2.3.34 firmware version cannot be downgraded to previous firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvement
- Updated the firmware version number for the purpose of keeping all ULX-D firmware version numbers aligned for brand-new system installations.
Notes
- User Guide
- To update firmware for ULXD6/8 transmitters with ULX-D or QLX-D receivers:
- Update receivers to the following minimum versions:
- ULXD4, ULXD4D, and ULXD4Q Receivers 2.1.16 or higher
- QLXD4 Receivers 2.1.5 or higher
- Using Shure Update Utility, download ULXD6/8 transmitter firmware to the receivers.
- Using the FW Update menu on a receiver, update transmitters.
- Update receivers to the following minimum versions:
- To update ULXD6/8 transmitters firmware while they are docked in an SBC250/450/850 Networked Charging Station:
- Place transmitters on charging station and ensure charging station is connected to the network.
- Launch Shure Update Utility to find firmware updates.
- Download updates and select Send Updates.
- To operate ULXD6/8 version 2.3.34 devices with other Shure networked systems and software, see the following list of recommended versions:
- ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.34
- SBC250/450/850 Networked Charging Stations 2.3.6
- QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.8
- Wireless Workbench 6.12.6
- Shure Update Utility 2.4.4
- ShurePlus Channels 1.4.2
Firmware
2.3.34
May 10, 2019
Zobacz wszystkie aktualizacje
Important
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
- New hardware revisions with the ULX-D 2.3.34 firmware version cannot be downgraded to previous firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvement
- Updated the firmware version number for the purpose of keeping all ULX-D firmware version numbers aligned for brand-new system installations.
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate ULX-D version 2.3.34 devices with other Shure networked systems and software, see the following list of minimum versions:
- ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.34
- SBC250/450/850 Networked Charging Stations 2.3.6
- QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.8
- PSM1000 1.6.21
- Axient AXT600 Spectrum Manager 2.1.22
- Wireless Workbench 6.12.6
- Shure Update Utility 2.4.4
- ShurePlus Channels 1.4.2
Firmware
2.3.34
May 10, 2019
Zobacz wszystkie aktualizacje
Important
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
- New hardware revisions with the ULX-D 2.3.34 firmware version cannot be downgraded to previous firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvement
- Updated the firmware version number for the purpose of keeping all ULX-D firmware version numbers aligned for brand-new system installations.
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate ULX-D version 2.3.34 devices with other Shure networked systems and software, see the following list of minimum versions:
- ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.34
- SBC250/450/850 Networked Charging Stations 2.3.6
- QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.8
- PSM1000 1.6.21
- Axient AXT600 Spectrum Manager 2.1.22
- Wireless Workbench 6.12.6
- Shure Update Utility 2.4.4
- ShurePlus Channels 1.4.2
Firmware
2.3.34
May 10, 2019
Zobacz wszystkie aktualizacje
Important
- New hardware revisions with the ULX-D 2.3.34 firmware version cannot be downgraded to previous firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvement
- Updated the firmware version number for the purpose of keeping all ULX-D firmware version numbers aligned for brand-new system installations.
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate ULX-D version 2.3.34 devices with other Shure networked systems and software, see the following list of minimum versions:
- ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.34
- SBC250/450/850 Networked Charging Stations 2.3.6
- QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.8
- PSM1000 1.6.21
- Axient AXT600 Spectrum Manager 2.1.22
- Wireless Workbench 6.12.6
- Shure Update Utility 2.4.4
- ShurePlus Channels 1.4.2
Firmware
2.3.34
May 10, 2019
Zobacz wszystkie aktualizacje
Important
- New hardware revisions with the ULX-D 2.3.34 firmware version cannot be downgraded to previous firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvement
- Added support for new hardware revisions.
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate ULX-D version 2.3.34 devices with other Shure networked systems and software, see the following list of minimum versions:
- ULX-D ULXD4/4D/4Q Receivers 2.3.34
- QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.8
- Axient AXT600 Spectrum Manager 2.1.22
- Wireless Workbench 6.12.6
- Shure Update Utility 2.4.4
- ShurePlus Channels 1.4.2
Firmware
1.1.4
April 17, 2019
Zobacz wszystkie aktualizacje
Improvements
- Resolved an issue that caused front panel display artifacts
- Bug fixes
Notes
- Command Strings
- To operate SBRC version 1.1.2 devices with other Shure software, see the following list of minimum versions:
- Shure Update Utility 2.4.4
- Wireless Workbench 6.12.6
Firmware
2.3.21
February 28, 2019
Zobacz wszystkie aktualizacje
Important
- Before ULX-D and QLX-D receivers can host or update ULXD6/8 firmware, they must be updated to the following minimum firmware versions:
- ULXD4, ULXD4D, and ULXD4Q Receivers 2.1.16 or higher
- QLXD4 Receivers 2.1.5 or higher
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all ULX-D devices to the same version.
Improvement
- Updated the firmware version number for the purpose of keeping all ULX-D firmware version numbers aligned for brand-new system installations.
Known Issue
- ULXD6/8 transmitters are not compatible with SystemOn 2.0-3.0.1.
Notes
- User Guide
- To update firmware for ULXD6/8 transmitters with ULX-D or QLX-D receivers:
- Update receivers to the following minimum versions:
- ULXD4, ULXD4D, and ULXD4Q Receivers 2.1.16 or higher
- QLXD4 Receivers 2.1.5 or higher
- Using Shure Update Utility, download ULXD6/8 transmitter firmware to the receivers.
- Using the FW Update menu on a receiver, update transmitters.
- Update receivers to the following minimum versions:
- To update ULXD6/8 transmitters firmware while they are docked in an SBC250/450/850 Networked Charging Station:
- Place transmitters on charging station and ensure charging station is connected to the network.
- Launch Shure Update Utility to find firmware updates.
- Download updates and select Send Updates.
- To operate ULXD6/8 version 2.3.21 devices with other Shure networked systems and software, see the following list of recommended versions:
- ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.21
- SBC250/450/850 Networked Charging Stations 2.3.6
- QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.2.11
- Wireless Workbench 6.12.6
- Shure Update Utility 2.4.3
- ShurePlus Channels 1.4.2
Firmware
2.3.21
February 28, 2019
Zobacz wszystkie aktualizacje
Important
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvement
- Support for Thailand 174 – 210 MHz frequency band (V52)
- Added separate locks for group scan and transmitter sync
- Enforcement of Access Control via Wireless Workbench to devices with remote connection has been fixed
Known Issue
- New hardware revisions of ULX-D version 2.3.21 are not compatible with SystemOn 2.0-3.0.1.
- ULX-D devices on J50A or L50A frequency bands are not compatible with SystemOn 2.0-3.0.1.
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate ULX-D version 2.3.21 devices with other Shure networked systems and software, see the following list of minimum versions:
- ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.21
- SBC250/450/850 Networked Charging Stations 2.3.6
- QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.2.11
- PSM1000 1.6.21
- Axient AXT600 Spectrum Manager 2.1.22
- Wireless Workbench 6.12.6
- Shure Update Utility 2.4.3
- ShurePlus Channels 1.4.2
Firmware
2.3.21
February 28, 2019
Zobacz wszystkie aktualizacje
Important
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvement
- Support for Thailand 174 – 210 MHz frequency band (V52)
- Added separate locks for group scan and transmitter sync
- Enforcement of Access Control via Wireless Workbench to devices with remote connection has been fixed
Known Issue
- New hardware revisions of ULX-D version 2.3.21 are not compatible with SystemOn 2.0-3.0.1.
- ULX-D devices on J50A or L50A frequency bands are not compatible with SystemOn 2.0-3.0.1.
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate ULX-D version 2.3.21 devices with other Shure networked systems and software, see the following list of minimum versions:
- ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.21
- SBC250/450/850 Networked Charging Stations 2.3.6
- QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.2.11
- PSM1000 1.6.21
- Axient AXT600 Spectrum Manager 2.1.22
- Wireless Workbench 6.12.6
- Shure Update Utility 2.4.3
- ShurePlus Channels 1.4.2
Firmware
2.3.21
February 28, 2019
Zobacz wszystkie aktualizacje
Important
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvement
- Support for Thailand 174 – 210 MHz frequency band (V52)
- Added separate locks for group scan and transmitter sync
- Enforcement of Access Control via Wireless Workbench to devices with remote connection has been fixed
Known Issues
- New hardware revisions of ULX-D version 2.3.21 are not compatible with SystemOn 2.0-3.0.1.
- ULX-D devices on J50A or L50A frequency bands are not compatible with SystemOn 2.0-3.0.1.
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate ULX-D version 2.3.21 devices with other Shure networked systems and software, see the following list of minimum versions:
- ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.21
- SBC250/450/850 Networked Charging Stations 2.3.6
- QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.2.11
- PSM1000 1.6.21
- Axient AXT600 Spectrum Manager 2.1.22
- Wireless Workbench 6.12.6
- Shure Update Utility 2.4.3
- ShurePlus Channels 1.4.2