2.0.5
September 22, 2014
Zobacz wszystkie aktualizacje
These release notes cover the following models:
- MXWNCS4/8
- MXWANI4/8
- MXWAPT4/8
NEW FEATURES
- Added new frequency band SKUs for Japan and Taiwan
- Added the ability to remotely identify a microphone without beeping the mic’s alarm
IMPROVEMENTS
- Moved the device IP Address Setting to the Utility Page, and enabled all IP edits to be batched.
- Fixed the compatibility issue with Mavericks “timing out” the MXWAPT GUI.
- Changed Factory reset button location to each individual device’s edit pop-up window.
- Updated the MXW Charger to be discoverable by the Shure Discovery Application 1.0.11 or higher
KNOWN ISSUES
- There may be issues staying connected to the GUI while using Safari on Mac OS X 10.9 Mavericks.
NOTES
- For operation of MXW devices with other Shure networked systems, see the following list of minimum software and firmware versions that are supported with MXW version 2.0.5:
- SCM820-DAN 1.1.211
- Shure Web Device Discovery 1.0.11
Firmware
2.0.5
September 22, 2014
Zobacz wszystkie aktualizacje
These release notes cover the following models:
- MXWNCS4/8
- MXWANI4/8
- MXWAPT4/8
NEW FEATURES
- Added new frequency band SKUs for Japan and Taiwan
- Added the ability to remotely identify a microphone without beeping the mic’s alarm
IMPROVEMENTS
- Moved the device IP Address Setting to the Utility Page, and enabled all IP edits to be batched.
- Fixed the compatibility issue with Mavericks “timing out” the MXWAPT GUI.
- Changed Factory reset button location to each individual device’s edit pop-up window.
- Updated the MXW Charger to be discoverable by the Shure Discovery Application 1.0.11 or higher
KNOWN ISSUES
- There may be issues staying connected to the GUI while using Safari on Mac OS X 10.9 Mavericks.
NOTES
- For operation of MXW devices with other Shure networked systems, see the following list of minimum software and firmware versions that are supported with MXW version 2.0.5:
- SCM820-DAN 1.1.211
- Shure Web Device Discovery 1.0.11
Firmware
1.0.15
September 9, 2014
Zobacz wszystkie aktualizacje
NOTES
- Initial release
- For operation of QLX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with QLX-D version 1.0.15:
- ULXD1/2 ULX-D Transmitters 1.5.6
- Wireless Workbench 6 version 6.10.0
Firmware
1.0.5
September 9, 2014
Zobacz wszystkie aktualizacje
NOTES
- Initial release
- For operation of QLX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with QLX-D version 1.0.15:
- ULXD1/2 ULX-D Transmitters 1.5.6
- Wireless Workbench 6 version 6.10.0
Firmware
1.5.6
June 25, 2014
Zobacz wszystkie aktualizacje
Important
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
New Features
- Interference Notifications for ULX-D are now displayed in Wireless Workbench 6.10 in the Interference Events dialog.
- ULX-D/QLX-D interoperability support. This release is required to support QLX-D transmitters. ULX-D receivers are compatible with QLX-D transmitters and will display QLXD1 or QLXD2 transmitter type given the following limitations
- QLX-D transmitters must be manually tuned to the same frequency as ULX-D receivers.
- Encryption must be disabled on both systems.
Improvements
- New Home Screen format displayed menu
- Simplified the ability to access and name both the Detailed per channel home screen and the ULXD4D/Q Summary screen by creating two separate menu structures.
Notes
- For operation of ULX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with ULX-D version 1.5.6:
- ULX-D ULXD1/2 Transmitters and ULXD4, ULXD4D, ULXD4Q Receivers 1.5.6
- Axient AXT400 Receivers and AXT600 Spectrum Managers 1.15.3
- Wireless Workbench 6 version 6.10.0
Firmware
1.5.6
June 25, 2014
Zobacz wszystkie aktualizacje
Important
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
New Features
- Interference Notifications for ULX-D are now displayed in Wireless Workbench 6.10 in the Interference Events dialog.
- ULX-D/QLX-D interoperability support. This release is required to support QLX-D transmitters. ULX-D receivers are compatible with QLX-D transmitters and will display QLXD1 or QLXD2 transmitter type given the following limitations
- QLX-D transmitters must be manually tuned to the same frequency as ULX-D receivers.
- ULX-D receivers cannot be in High Density mode (High Density mode is not available on QLX-D receivers)
- Encryption must be disabled on both systems.
Improvements
- New Home Screen format displayed menu
- Simplfied the ability to access and name both the Detailed per channel home screen and the ULXD4D/Q Summary screen by creating two separate menu structures.
Notes
- For operation of ULX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with ULX-D version 1.5.6:
- ULX-D ULXD1/2 Transmitters and ULXD4, ULXD4D, ULXD4Q Receivers 1.5.6
- Axient AXT400 Receivers and AXT600 Spectrum Managers 1.15.3
- Wireless Workbench 6 version 6.10.0
Firmware
1.5.6
June 25, 2014
Zobacz wszystkie aktualizacje
New Features
- Interference Notifications for ULX-D are now displayed in Wireless Workbench 6.10 in the Interference Events dialog.
- ULX-D/QLX-D interoperability support. This release is required to support QLX-D transmitters. ULX-D receivers are compatible with QLX-D transmitters and will display QLXD1 or QLXD2 transmitter type given the following limitations
- QLX-D transmitters must be manually tuned to the same frequency as ULX-D receivers.
- ULX-D receivers cannot be in High Density mode (High Density mode is not available on QLX-D receivers)
- Encryption must be disabled on both systems.
Notes
- After updating the ULXD4 Single Receiver from version 1.0.7, the user is required to reset the unit to Default Settings (DEVICE UTILITIES/SYSTEM RESET/RESTORE/DEFAULT SETTINGS).
- For operation of ULX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with ULX-D version 1.5.6:
- ULX-D ULXD1/2 Transmitters and ULXD4, ULXD4D, ULXD4Q Receivers 1.5.6
- Axient AXT400 Receivers and AXT600 Spectrum Managers 1.15.3
- Wireless Workbench 6 version 6.10.0
Firmware
1.5.6
June 25, 2014
Zobacz wszystkie aktualizacje
New Features
- ULX-D/QLX-D Interoperability support. This release is required to support using ULX-D transmitters with QLX-D receivers. The following limitations apply:
- QLX-D transmitters must be manually tuned to the same frequency as ULX-D receivers.
- Encryption must be disabled on both systems.
- QLX-D will not display transmitter type, but Wireless Workbench 6 will display the transmitter type as ULXD1/ULXD2.
Notes
- After updating the ULXD4 Single Receiver the user is required to reset the unit to Default Settings (DEVICE UTILITIES/SYSTEM RESET/RESTORE/DEFAULT SETTINGS).
- For operation of ULX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with ULX-D version 1.5.6:
- ULX-D ULXD1/2 Transmitters and ULXD4, ULXD4D, ULXD4Q Receivers 1.5.6
- Axient AXT400 Receivers and AXT600 Spectrum Managers 1.15.3
- Wireless Workbench 6 version 6.10.0
Firmware
1.15.3
June 25, 2014
Zobacz wszystkie aktualizacje
NOTES
- For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.15.3:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4x ULX-D Receivers 1.5.6
- QLXD4 QLX-D Receiver 1.0.13
- P10T PSM1000 Transmitter 1.3.9
- Wireless Workbench 6.10.0
Firmware
1.15.3
June 25, 2014
Zobacz wszystkie aktualizacje
IMPROVEMENTS
- Supports updated group & channel maps for bands: G19, H18, J12, and L20
- Supports P10T frequency bands: G10J, J8J, L11J, and L8J
- Supports QLX-D Digital Wireless System
- Discovers QLX-D channels
- Coordinates frequencies for QLX-D channels
- Supports entry and maintenance of missing band information for CFL entries.
- Requires all CFL entries edited/added from AXT600 to specify band values.
NOTES
- For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.15.3:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4x ULX-D Receivers 1.5.6
- QLXD4 QLX-D Receiver 1.0.13
- P10T PSM1000 Transmitter 1.3.9
- Wireless Workbench 6.10.0