Software & Firmware Archives
RECOMMENDATION
Update all Axient devices in a configuration to the same firmware version.
NEW FEATURES
- Access Control: When activated, it enables users to specify a PIN from Wireless Workbench 6.12 to protect the device from being changed by unauthenticated users of Wireless Workbench 6.12 and ShurePlus Channels. The Access Control status is visible on AXT600.
IMPROVEMENTS
- Low speed added to Fan Mode.
- Users pressing Enter while in Util > Network will remain in Util > Network instead of jumping to the Home menu.
- Discover ULX-D and QLX-D receivers in V50 and V51 bands* over the network.
*AXT600 is capable of discovering ULX-D and QLX-D receivers in X52, X53, X54 and Z16 bands. AXT600 will continue to scan within the range of 470-865, 925-952MHz. In the AXT600 band summary list, any band that is not fully supported due to non-tunable frequencies is tagged with *. In the AXT600 CFL list, non-tunable frequencies are indicated with "Monitor for WWB (unknown dBm)". When listening to CFL frequencies, switching to a non-tunable frequency will turn the Listen mode off. The AXT600 CFL Edit/Add menu will allow any frequency for any band, not limited to tunable frequencies.
NOTES
- For operation of Axient devices with other Shure networked systems, see the following list of minimum versions that are supported with Axient version 1.17.10:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4X ULX-D Receivers 2.0.19
- QLXD4 QLX-D Receiver 1.1.15
- P10T PSM1000 Transmitter 1.4.2
- Wireless Workbench 6.12
RECOMMENDATION
Update all Axient devices in a configuration to the same firmware version.
NEW FEATURE
- Access Control: When activated, it enables users to specify a PIN from Wireless Workbench 6.12 to protect the device from being changed by unauthenticated users of Wireless Workbench 6.12 and ShurePlus Channels 1.3. The Access Control status is visible on AXT400.
IMPROVEMENTS
- Updated AXT910/AXT920 fuel gauge errors.
- Low speed added to Fan Mode.
- Users pressing Enter while in Util > Network will remain in Util > Network instead of jumping to the Home menu.
KNOWN ISSUE
- When an AXT400 J is set to one of the newly supported UHF-R bands (e.g. G1HK, H4HK, J5HK, L3HK), downgrading the AXT400 J unit from 1.17.10 to 1.15.3 may result in abnormal frequency indication (e.g. 0.000 MHz) as well as a change in the RF band.
NOTES
- For operation of Axient devices with other Shure networked systems, see the following list of minimum versions that are supported with Axient version 1.17.10:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4X ULX-D Receivers 2.0.19
- QLXD4 QLX-D Receiver 1.1.15
- P10T PSM1000 Transmitter 1.4.2
- Wireless Workbench 6.12
- ShurePlus Channels 1.3
RECOMMENDATION
Update all Axient devices in a configuration to the same firmware version.
NEW FEATURE
- Factory reset
IMPROVEMENTS
- Updated AXT910/AXT920 fuel gauge errors.
- Added ability to send Talk Switch controls with the UHF audio carrier.
NOTES
- Transmitters to be used with receivers must be updated via IR. After the receiver is updated, go to the receiver menu: Tx > IRPresets > FWUpdate. Align the infrared ports with the transmitter and press Download.
- For operation of Axient devices with other Shure networked systems, see the following list of minimum versions that are supported with Axient version 1.17.10:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4X ULX-D Receivers 2.0.19
- QLXD4 QLX-D Receiver 1.1.15
- P10T PSM1000 Transmitter 1.4.2
- Wireless Workbench 6.12
RECOMMENDATION
Update all Axient devices in a configuration to the same firmware version.
NEW FEATURES
- RF Mute added to the Power Indicator LED
- Factory reset
IMPROVEMENTS
- Updated AXT910/AXT920 fuel gauge errors
- Added ability to send Talk Switch controls with the UHF audio carrier.
NOTES
- Transmitters to be used with receivers must be updated via IR. After the receiver is updated, go to the receiver menu: Tx > IRPresets > FWUpdate. Align the infrared ports with the transmitter and press Download.
- For operation of Axient devices with other Shure networked systems, see the following list of minimum versions that are supported with Axient version 1.17.10:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULXD4X ULX-D Receivers 2.0.19
- QLXD4 QLX-D Receiver 1.1.15
- P10T PSM1000 Transmitter 1.4.2
- Wireless Workbench 6.12
Improvements
- Network Audio LED turns off when no Dante Channels are routed
- Push to Dante feature now appends a -d to the Dante Device Name, preventing discovery issues
- Bug fixes
Known Issue
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- ANI4OUT version 1.2.6 is compatible with microphones running version 1.2.6 and below, but it is recommended to update all devices used together to the same firmware version.
- For operation of ANI4OUT version 1.2.6 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI4IN 1.1.6
- MXA310 1.1.4
- MXA910 1.1.3
- Microflex Wireless 4.0.7
- ULXD4 1.7.34
- ULXD4Q 1.7.34
- SCM820 1.3.3
- Shure Update Utility 2.2.2
- Shure Web Device Discovery 1.0.18
Improvements
- Network Audio LED turns off when no Dante Channels are routed
- Push to Dante feature now appends a -d to the Dante Device Name, preventing discovery issues
- Bug fixes
Known Issue
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- ANI4IN version 1.2.6 is compatible with microphones running version 1.2.6 and below, but it is recommended to update all devices used together to the same firmware version.
- For operation of ANI4IN version 1.2.6 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI4OUT 1.1.6
- MXA310 1.1.4
- MXA910 1.1.3
- Microflex Wireless 4.0.7
- ULXD4 1.7.34
- ULXD4Q 1.7.34
- SCM820 1.3.3
- Shure Update Utility 2.2.2
- Shure Web Device Discovery 1.0.18
Initial Release
Known Issues
- Remote Microflex Wireless Transmitter Linking is not available with SystemOn 2.0. This feature will be available in a future software update.
- Microflex Wireless Audio and RF metering information is not available with SystemOn 2.0. This feature will be available in a future software update.
- If Chrome shows an “Aw, Snap!” error page, reload the page or close other tabs to fix the error.
- UTC time and date are displayed on Event Log and Email/SMS notifications.
- If a valid license activation ID is applied and fails on the first attempt, retry a second time before calling support.
- Monitoring widget may show erroneous characters for a short time period for Microflex Wireless (MXW) microphones on Standby mode.
Notes
- To operate SystemOn 2.0 with Shure networked systems, see the following list of firmware versions that are supported with SystemOn 2.0:
- SCM820 1.3.3
- ULX-D 1.7.34
- MXW 4.0.6-4.0.7
- Please report any SystemOn 2.0 performance issues on Internet Explorer and Microsoft Edge browsers to Shure Support.
- For help and troubleshooting, go to the SystemOn User Guide or FAQs
New Feature
- Support for Access Control, which allows users to specify PINs for networked devices in order to restrict access to them from unauthenticated users of Wireless Workbench (version 6.12 or later) and ShurePlus Channels (version 1.3 or later).
Known Issue
- ShurePlus Channels version 1.2 does not currently support P10R/P10T version 1.4 or later.
Notes
- For operation of PSM1000 devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with firmware version 1.4.2:
- Axient 1.16.11
- ULX-D 2.0.19
- Wireless Workbench 6.12
- Shure Update Utility 2.2.2
- ShurePlus Channels 1.3
New Feature
- Support for Access Control, which allows users to specify PINs for networked devices in order to restrict access to them from unauthenticated users of Wireless Workbench (version 6.12 or later) and ShurePlus Channels (version 1.3 or later).
Known Issue
- ShurePlus Channels version 1.2 does not currently support P10R/P10T version 1.4 or later.
Notes
- For operation of PSM1000 devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with firmware version 1.4.2:
- Axient 1.16.11
- ULX-D 2.0.19
- Wireless Workbench 6.12
- Shure Update Utility 2.2.2
- ShurePlus Channels 1.3
NEW FEATURES
- DC6990P - Support for colours on voting buttons
- 6000, 5900 - Support for "Speak Button Lock". Settings available from CU5905/CU6110/CCU web interface. The ‘Lock Override Time (Long Push Time)’ and the ‘Lock Duration’ is settable from the web interface.
- 6000, 5900 - Support for "Allow Mic Off". Settings available from CU5905/CU6110/CCU web interface
- DC6990, DC6190, DM6680, DC59xx - Support for "Long Push" to overrule Speak Button Lock
IMPROVEMENTS
- CU5905/CU6110/CCU – Audio In Volume, Level & Muted settings were not stored correctly in CU configuration. Making changes to Audio In 1 caused changes to be used for Audio In 2 after next reboot and vice versa
- CU61xx, CCU - Electrical clicking noise removed from interpreter microphone LED when microphone is activated
- CU5905/CU6110/CCU – Setting Audio In2 -> Loudspeaker from front plate does not work
- CU61xx, CCU - Setting an Interpreter Unit to same A and B outgoing channel will cause audio to become lost if interpreter switch outgoing channel between A and B with Interpreter Unit engaged
- PCB6000 (Flush mounted units) - Vote LED indication not correctly updated on chip card login during voting session if user has voted previously in the same session
- DC6990P – Speech time not stopped on delegates during Exclusive On
- DC6990P – Seat names not updated correctly on unit type change
FIRMWARE UPGRADE UTILITY (FUU) V1489
- An issue in FUU was fixed where units with old firmware were cleared on a CU6010 when they became locked - hereby preventing an upgrade. (CONFFW-558)
- Timestamps added to Upgrade Log.
- FUU will now by default look for a FUU library in a the released folder structure.