Downloads
Software & Firmware Archives
Firmware
4.3.6
23/11/2020
Ver todas las Actualizaciones
Improvement
- Bug Fixes
Known Issues
- Factory reset occasionally fails to reset Dante settings and/or fully disable encryption. Solution: Reboot the device if unable to route audio after factory reset.
- AES67 support is only available on UltimoX hardware
- MXA310 devices manufactured as of July 2017 are compatible with AES67
- Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 or later firmware to use this feature
- If enrolling, unenrolling, or changing Dante Domain settings and selecting “Clear Config,” the device may mute its audio output indefinitely. Solution: Reboot the device following this operation to avoid possible adverse behavior.”
- After updating from version 2.X to 4.2, Channel EQ settings return to their default settings.
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
- When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
- The Mute Control Function command string response is incorrect when using <GET 0 ALL>
- When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
- When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > Response | Actual MUTE_CONTROL_FUNC |
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC > | LOCAL |
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL > | LOGIC |
< REP MUTE_BUTTON OFF > | DISABLED |
Notes
- User Guide
- Demo Web UI
- Command Strings
- MXA310 version 4.3.X is compatible with MXA310 devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
- To operate MXA310 version 4.3.X with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate MXA310 version 4.3.X with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
- Shure Designer 4.3.0
- Shure SystemOn 4.3.0
- ANI22 4.3.7
- ANI4IN 4.3.7
- ANI4OUT 4.3.7
- ANIUSB-MATRIX 4.3.11
- MXA910 4.3.2
- MXA710 1.1.5
- MXA-MUTE 1.1.3
- MXN5-C 1.1.1
- Microflex Wireless 8.0.3
- P300 IntelliMix® Audio Conferencing Processor 4.3.7
- SCM820 1.3.3
- Shure Update Utility 2.5.0
- Shure Web Device Discovery 1.2.9
Firmware
4.3.6
23/11/2020
Ver todas las Actualizaciones
Improvement
- Bug Fixes
Known Issues
- Factory reset occasionally fails to reset Dante settings and/or fully disable encryption. Solution: Reboot the device if unable to route audio after factory reset.
- AES67 support is only available on UltimoX hardware
- MXA310 devices manufactured as of July 2017 are compatible with AES67
- Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 or later firmware to use this feature
- If enrolling, unenrolling, or changing Dante Domain settings and selecting “Clear Config,” the device may mute its audio output indefinitely. Solution: Reboot the device following this operation to avoid possible adverse behavior.”
- After updating from version 2.X to 4.2, Channel EQ settings return to their default settings.
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
- When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
- The Mute Control Function command string response is incorrect when using <GET 0 ALL>
- When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
- When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > Response | Actual MUTE_CONTROL_FUNC |
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC > | LOCAL |
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL > | LOGIC |
< REP MUTE_BUTTON OFF > | DISABLED |
Notes
- User Guide
- Demo Web UI
- Command Strings
- MXA310 version 4.3.X is compatible with MXA310 devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
- To operate MXA310 version 4.3.X with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate MXA310 version 4.3.X with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
- Shure Designer 4.3.0
- Shure SystemOn 4.3.0
- ANI22 4.3.7
- ANI4IN 4.3.7
- ANI4OUT 4.3.7
- ANIUSB-MATRIX 4.3.11
- MXA910 4.3.2
- MXA710 1.1.5
- MXA-MUTE 1.1.3
- MXN5-C 1.1.1
- Microflex Wireless 8.0.3
- P300 IntelliMix® Audio Conferencing Processor 4.3.7
- SCM820 1.3.3
- Shure Update Utility 2.5.0
- Shure Web Device Discovery 1.2.9
Firmware
1.1.3
23/11/2020
Ver todas las Actualizaciones
Improvements
- Bug fixes
Notes
- User Guide
- Command Strings
- To operate MXA-MUTE version 1.1.3 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
- Shure Designer 4.3.0
- ANIUSB-MATRIX 4.3.11
- MXA310 4.3.6
- MXA910 4.3.2
- MXA710 1.1.5
- MXN5-C 1.1.1
- P300 IntelliMix® Audio Conferencing Processor 4.3.7
- Shure Update Utility 2.5.0
- Shure Web Device Discovery 1.2.9
Firmware
1.1.1
23/11/2020
Ver todas las Actualizaciones
Improvements
- Bug fixes
Notes
- User Guide
- Command Strings
- To operate MXN5-C version 1.1.1 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate MXN5-C version 1.1.1 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
- Shure Designer 4.3
- ANI22 4.3.7
- ANI4IN 4.3.7
- ANI4OUT 4.3.7
- ANIUSB-MATRIX 4.3.11
- MXA310 4.3.6
- MXA910 4.3.2
- MXA710 1.1.5
- Microflex Wireless 8.0.3
- P300 IntelliMix® Audio Conferencing Processor 4.3.7
- IntelliMix® Room 2.0.1
- ULXD4D/4Q 2.4.9
- SCM820 1.3.3
- Shure Update Utility 2.5.0
- Shure Web Device Discovery 1.2.9
Firmware
1.1.5
23/11/2020
Ver todas las Actualizaciones
Improvements
- Bug fixes
Notes
- User Guide
- Command Strings
- To operate MXA710 version 1.0.5 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate MXA710 version 1.1.5 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
- Shure Designer 4.3.0
- MXA-MUTE 1.1.3
- MXN5-C 1.1.1X
- MXA910 4.1.413.2
- ANI22 4.3.7
- ANI4IN 4.3.7
- ANI4OUT 4.3.7
- ANIUSB-MATRIX 4.3.11
- MXA310 4.3.6
- Microflex Wireless 8.0.3
- P300 IntelliMix® Audio Conferencing Processor 4.3.7
- ULXD4D/4Q 2.4.9
- SCM820 1.3.3
- Shure Update Utility 2.5.0
- Shure Web Device Discovery 1.2.9
Firmware
1.1.5
23/11/2020
Ver todas las Actualizaciones
Improvements
- Bug fixes
Notes
- User Guide
- Command Strings
- To operate MXA710 version 1.0.5 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate MXA710 version 1.1.5 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
- Shure Designer 4.3.0
- MXA-MUTE 1.1.3
- MXN5-C 1.1.1X
- MXA910 4.1.413.2
- ANI22 4.3.7
- ANI4IN 4.3.7
- ANI4OUT 4.3.7
- ANIUSB-MATRIX 4.3.11
- MXA310 4.3.6
- Microflex Wireless 8.0.3
- P300 IntelliMix® Audio Conferencing Processor 4.3.7
- ULXD4D/4Q 2.4.9
- SCM820 1.3.3
- Shure Update Utility 2.5.0
- Shure Web Device Discovery 1.2.9
Firmware
4.3.11
23/11/2020
Ver todas las Actualizaciones
Improvements
- USB Audio and Mute sync improvements
- Improved performance with USB extending
- Chrome OS Audio support
- Mute sync improvements - Microsoft Teams, Zoom, and Skype for Business
Bug Fixes
- Fixed an issue with Barco ClickShare CX50, where the ANIUSB-MATRIX was recognized but no audio was passed
- Additional bug fixes and enhancements
Known Issues
- Pop noise is triggered when the channel is unrouted in Dante controller
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported.
- When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)
- Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware or newer to use this feature
Notes
- User Guide
- Command Strings
- ANIUSB-MATRIX version 4.3.11 is compatible with ANIUSB-MATRIX devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
- To operate ANIUSB-MATRIX version 4.3.11 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
- To operate ANIUSB-MATRIX 4.3.11 with Microsoft Teams, reference the following minimum versions:
- Microsoft Teams Desktop: 1.3.00.24755
- Microsoft Teams Rooms: 4.6.20.0
- To operate ANIUSB-MATRIX version 4.3.11 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
- Shure Designer 4.3.0
- ANI22 4.3.7
- ANI4IN 4.3.7
- ANI4OUT 4.3.7
- MXA310 4.3.6
- MXA910 4.3.2
- Microflex Wireless 8.0.3
- P300 4.3.7
- ULXD4D/4Q 2.4.9
- SCM820 1.3.3
- Shure Update Utility 2.5.0
- Shure Web Device Discovery 1.2.9
Firmware
4.3.7
23/11/2020
Ver todas las Actualizaciones
Improvements
- Bug fixes
Known Issues
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
- Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
Notes
- User Guide
- Command Strings
- ANI22 version 4.3.7 is compatible with ANI22 devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
- To operate ANI22 version 4.1.39 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
- To operate ANI22 version 4.3.7 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI4IN 4.3.7
- ANI4OUT 4.3.7
- ANIUSB-MATRIX 4.3.11
- MXA310 4.3.6
- MXA910 4.3.2
- Microflex Wireless 8.0.3
- ULXD4D/4Q 2.4.9
- SCM820 1.3.3
- Shure Update Utility 2.5.0
- Shure Web Device Discovery 1.2.9
Firmware
4.3.7
23/11/2020
Ver todas las Actualizaciones
Improvements
- Bug fixes
Known Issues
- AES67 support is only available on UltimoX hardware
- ANI4IN devices manufactured as of January 2018 are compatible with AES67
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
- Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
Notes
- User Guide
- Command Strings
- ANI4IN version 4.3.7 is compatible with ANI4IN devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
- To operate ANI4IN version 4.1.7 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate ANI4IN version 4.1.7 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI22 4.3.7
- ANI4OUT 4.3.7
- ANIUSB-MATRIX 4.3.11
- MXA310 4.3.6
- MXA910 4.3.2
- Microflex Wireless 8.0.3
- P300 4.3.7
- ULXD4D/4Q 2.4.9
- SCM820 1.3.3
- Shure Update Utility 2.5.0
- Shure Web Device Discovery 1.2.9
Firmware
4.3.7
23/11/2020
Ver todas las Actualizaciones
Improvements
- Bug fixes
Known Issues
- AES67 support is only available on UltimoX hardware
- ANI4IN devices manufactured as of January 2018 are compatible with AES67
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
- Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
Notes
- User Guide
- Command Strings
- ANI4IN version 4.3.7 is compatible with ANI4IN devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
- To operate ANI4IN version 4.1.7 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate ANI4IN version 4.1.7 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI22 4.3.7
- ANI4OUT 4.3.7
- ANIUSB-MATRIX 4.3.11
- MXA310 4.3.6
- MXA910 4.3.2
- Microflex Wireless 8.0.3
- P300 4.3.7
- ULXD4D/4Q 2.4.9
- SCM820 1.3.3
- Shure Update Utility 2.5.0
- Shure Web Device Discovery 1.2.9