Downloads
Software & Firmware Archives
Software
2.4.1
6/11/2017
Ver todas las Actualizaciones
Note
Important
To update Shure Update Utility (version 2.4 or earlier) to version 2.4.1, download and re-install from Shure.com/SUU and not through Help > Check for Shure Update Utility updates.
Improvements
- Returned support of Shure Update Utility for 32-bit Windows operating systems. To update Shure Update Utility (versions 2.2.2 or earlier) on a 32-bit Windows system, download version 2.4.1 for 32-bit systems to re-install the software.
- Added support for PSM1000 G62
Known Issues
- 32-Bit Windows
- Selecting "Help" > "Check for Shure Update Utility updates" will open Shure.com, which offers the latest version of Shure Update Utility to download. Shure Update Utility version 2.4.1 will not automatically detect new versions.
- To update Shure Update Utility (versions 2.2.2 or earlier) on a 32-bit Windows system, download version 2.4.1 for 32-bit systems to re-install the software. Older versions of Shure Update Utility will not detect new updates of Shure Update Utility that support 32-bit systems.
- Shure Update Utility version 2.4.1 for 32-bit systems is compatible with Wireless Workbench 6 version 6.12 or earlier.
- Attempts to download ULXD6/8 transmitter firmware to a ULX-D or QLX-D receiver that is not at the minimum firmware version will fail. To update firmware for ULXD6/8 transmitters with ULX-D or QLX-D receivers:
- Update receivers to the following minimum versions:
- ULXD4, ULXD4D, ULXD4Q Receivers 2.1.16
- QLXD4 Receivers 2.1.5
- Using Shure Update Utility, download ULXD6/8 transmitter firmware to the receivers.
- Using the FW Update menu on a receiver, update transmitters.
- Update receivers to the following minimum versions:
- Microflex Wireless devices running version 1.X firmware must first be updated to version 2.0.5 before being updated to version 3.X or later.
Notes
- Installing Shure Update Utility on Windows will also prompt the installation of a USB driver, which must be installed to support updating USB devices, like GLX-D.
- USB 2.0 Devices
- KSE1500, SHA900 and GLX-D (USB 2.0 connected devices) must be updated one at a time.
- USB hubs are not recommended when updating USB 2.0 connected devices. Always connect these devices directly to a USB terminal of the computer running Shure Update Utility.
- Shure Update Utility 2.4.1 for 64-bit systems is compatible with Wireless Workbench 6.12.2 or later.
- Shure Update Utility 2.4.1 for 32-bit systems is compatible with Wireless Workbench 6.12 or earlier.
Firmware
2.0.16
6/11/2017
Ver todas las Actualizaciones
Recommendation
Update all MXA910 devices in a configuration to the same firmware version.
Improvements
- Fixed an issue where the low-shelf filter fails after importing a preset file.
Known Issue
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- MXA910: User Guide | Command Strings
- MXA910 version 2.0.16 is compatible with MXA910 devices running version 2.0.16 and below, but it is recommended to update all devices used together to the same firmware version.
- To operate MXA910 version 2.0.16 with Dante™ Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate MXA910 version 2.0.16 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI4IN 2.0.7
- ANI4OUT 2.0.8
- MXA310 2.0.8
- Microflex Wireless 5.1.23
- ULXD4D/4Q 2.1.16
- SCM820 1.3.3
- Shure Update Utility 2.3
- Shure Web Device Discovery 1.1
- Designer 3.0
Firmware
1.0.18
16/10/2017
Ver todas las Actualizaciones
New Feature
- Initial firmware for the AD610 Diversity ShowLink Access Point
Notes
- To operate AD610 version 1.0.18 devices with other Shure systems and software, see the following list of minimum versions:
- Axient Digital AD1/2 Transmitters 1.0.17
- Axient Digital AD4D/Q Receivers 1.0.17
- SBRC Shure Battery Rack Charger 1.0.1
- Shure Update Utility 2.4
- ShurePlus Channels 1.4
- Wireless Workbench 6.12.2
Firmware
5.1.26
16/10/2017
Ver todas las Actualizaciones
Improvements
- Fixed an issue on the MXWANI control software that prevented channels name changes that were more than 12 characters.
- .svn files removed from the HTML directories of MXWANI4/8.
Known Issues
- During Spectrum Scan, modifying MXWAPT configuration settings can put the device in a non-deterministic state. If configuration settings are modified during Spectrum Scan, MXWAPT must be rebooted.
- Microflex Wireless 5.1.26 is not supported by SystemOn version 3.0.
Notes
- Microflex Wireless firmware version 5.1.26 does not support AES67.
- To operate MXW version 5.1.26 with other Shure networked systems, see the following list of minimum software and firmware versions:
- SCM820 1.3.3
- Shure Web Device Discovery 1.1
- Shure Update Utility 2.4
Firmware
5.1.26
16/10/2017
Ver todas las Actualizaciones
Improvements
- Fixed an issue on the MXWANI control software that prevented channels name changes that were more than 12 characters.
- .svn files removed from the HTML directories of MXWANI4/8.
Known Issues
- During Spectrum Scan, modifying MXWAPT configuration settings can put the device in a non-deterministic state. If configuration settings are modified during Spectrum Scan, MXWAPT must be rebooted.
- Microflex Wireless 5.1.26 is not supported by SystemOn version 3.0.
Notes
- Microflex Wireless firmware version 5.1.26 does not support AES67.
- To operate MXW version 5.1.26 with other Shure networked systems, see the following list of minimum software and firmware versions:
- SCM820 1.3.3
- Shure Web Device Discovery 1.1
- Shure Update Utility 2.4
Firmware
5.1.26
16/10/2017
Ver todas las Actualizaciones
Improvements
- Fixed an issue on the MXWANI control software that prevented channels name changes that were more than 12 characters.
- .svn files removed from the HTML directories of MXWANI4/8.
Known Issues
- During Spectrum Scan, modifying MXWAPT configuration settings can put the device in a non-deterministic state. If configuration settings are modified during Spectrum Scan, MXWAPT must be rebooted.
- Microflex Wireless 5.1.26 is not supported by SystemOn version 3.0.
Notes
- Microflex Wireless firmware version 5.1.26 does not support AES67.
- To operate MXW version 5.1.26 with other Shure networked systems, see the following list of minimum software and firmware versions:
- SCM820 1.3.3
- Shure Web Device Discovery 1.1
- Shure Update Utility 2.4
Firmware
5.1.26
16/10/2017
Ver todas las Actualizaciones
Improvements
- Fixed an issue on the MXWANI control software that prevented channels name changes that were more than 12 characters.
- .svn files removed from the HTML directories of MXWANI4/8.
Known Issues
- During Spectrum Scan, modifying MXWAPT configuration settings can put the device in a non-deterministic state. If configuration settings are modified during Spectrum Scan, MXWAPT must be rebooted.
- Microflex Wireless 5.1.26 is not supported by SystemOn version 3.0.
Notes
- Microflex Wireless firmware version 5.1.26 does not support AES67.
- To operate MXW version 5.1.26 with other Shure networked systems, see the following list of minimum software and firmware versions:
- SCM820 1.3.3
- Shure Web Device Discovery 1.1
- Shure Update Utility 2.4
Firmware
5.1.26
16/10/2017
Ver todas las Actualizaciones
Improvements
- Fixed an issue on the MXWANI control software that prevented channels name changes that were more than 12 characters.
- .svn files removed from the HTML directories of MXWANI4/8.
Known Issues
- During Spectrum Scan, modifying MXWAPT configuration settings can put the device in a non-deterministic state. If configuration settings are modified during Spectrum Scan, MXWAPT must be rebooted.
- Microflex Wireless 5.1.26 is not supported by SystemOn version 3.0.
Notes
- Microflex Wireless firmware version 5.1.26 does not support AES67.
- To operate MXW version 5.1.26 with other Shure networked systems, see the following list of minimum software and firmware versions:
- SCM820 1.3.3
- Shure Web Device Discovery 1.1
- Shure Update Utility 2.4
Firmware
5.1.26
16/10/2017
Ver todas las Actualizaciones
Improvements
- Fixed an issue on the MXWANI control software that prevented channels name changes that were more than 12 characters.
- .svn files removed from the HTML directories of MXWANI4/8.
Known Issues
- During Spectrum Scan, modifying MXWAPT configuration settings can put the device in a non-deterministic state. If configuration settings are modified during Spectrum Scan, MXWAPT must be rebooted.
- Microflex Wireless 5.1.26 is not supported by SystemOn version 3.0.
Notes
- Microflex Wireless firmware version 5.1.26 does not support AES67.
- To operate MXW version 5.1.26 with other Shure networked systems, see the following list of minimum software and firmware versions:
- SCM820 1.3.3
- Shure Web Device Discovery 1.1
- Shure Update Utility 2.4
Firmware
5.1.26
16/10/2017
Ver todas las Actualizaciones
Improvements
- Fixed an issue on the MXWANI control software that prevented channels name changes that were more than 12 characters.
- .svn files removed from the HTML directories of MXWANI4/8.
Known Issues
- During Spectrum Scan, modifying MXWAPT configuration settings can put the device in a non-deterministic state. If configuration settings are modified during Spectrum Scan, MXWAPT must be rebooted.
- Microflex Wireless 5.1.26 is not supported by SystemOn version 3.0.
Notes
- Microflex Wireless firmware version 5.1.26 does not support AES67.
- To operate MXW version 5.1.26 with other Shure networked systems, see the following list of minimum software and firmware versions:
- SCM820 1.3.3
- Shure Web Device Discovery 1.1
- Shure Update Utility 2.4