Downloads

Archiwum oprogramowania i firmware

Filter by update type

Type

Release Title

Latest Version

Associated Products

Pobierz

Firmware
2.7.3

Important

  • ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
  • ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
  • After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version. 

Known Issues

  • Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.7.3
    • Axient AXT600 Spectrum Manager 2.1.41
    • SBC250/450/850 Networked Charging Stations 2.7.3
    • Shure Update Utility 2.7.2
    • ShurePlus Channels iOS 1.5.2
    • ShurePlus Channels Android 1.1.1
    • Wireless Workbench 6.15.0
Firmware
2.7.3

Important

  • ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
  • ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
  • After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Known Issues

  • Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.7.3
    • Axient AXT600 Spectrum Manager 2.1.41
    • SBC250/450/850 Networked Charging Stations 2.7.3
    • Shure Update Utility 2.7.2
    • ShurePlus Channels iOS 1.5.2
    • ShurePlus Channels Android 1.1.1
    • Wireless Workbench 6.15.0
Firmware
2.7.3

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version. 

Notes

  • User Guide
  • To update firmware for ULXD6/8 transmitters with ULX-D or QLX-D receivers:
    1. Update receivers to the following minimum versions:
      • ULXD4, ULXD4D, and ULXD4Q Receivers 2.1.16 or higher
      • QLXD4 Receivers 2.1.5 or higher
    2. Using Shure Update Utility, download ULXD6/8 transmitter firmware to the receivers.
    3. Using the FW Update menu on a receiver, update transmitters.
  • To update ULXD6/8 transmitters firmware while they are docked in an SBC250/450/850 Networked Charging Station:
    1. Place transmitters on charging station and ensure charging station is connected to the network.
    2. Launch Shure Update Utility to find firmware updates.
    3. Download updates and select Send Updates.
  • To operate this version of ULXD6/8 devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.7.3
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.5.2 
    • SBC250/450/850 Networked Charging Stations 2.7.3
    • Shure Update Utility 2.7.2
    • ShurePlus Channels iOS 1.5.2
    • ShurePlus Channels Android 1.1.1
    • Wireless Workbench 6.15.0
Firmware
2.7.3

Notes 

  • SBC250 User Guide
  • SBC450/850 User Guide
  • To set up ULXD6/8 transmitters to receive firmware updates while docked in SBC250/450/850 Networked Charging Stations, follow these steps: 
    1. Place transmitters on a charging station and ensure the charging station is connected to the network. 
    2. Launch Shure Update Utility to find firmware updates. 
    3. Download updates and select Send Updates. 
  • To operate this version of SBC250/450/850 with other Shure networked systems and software, see the following list of recommended versions: 
    • ULX-D ULXD6/8 Transmitters and ULXD4/4D/4Q Receivers 2.7.3
    • Shure Update Utility 2.7.2
    • Wireless Workbench 6.15.0