Downloads
Archiwum oprogramowania i firmware
Firmware
1.0.17
August 3, 2017
Zobacz wszystkie aktualizacje
New Feature
- Initial release
Notes
- To operate AD4D version 1.0.17 devices with other Shure systems and software, see the following list of minimum versions:
- Axient Digital AD1/2 Transmitters 1.0.17
- Axient Digital AD4D/Q Receivers 1.0.17
- Axient AXT600 Spectrum Manager 2.0.X
- SBRC Shure Battery Rack Charger 1.0.1
- Shure Update Utility 2.4
- ShurePlus Channels 1.4
- Wireless Workbench 6.12.2
Firmware
2.0.8
July 7, 2017
Zobacz wszystkie aktualizacje
Recommendation
Update all MXA910 devices in a configuration to the same firmware version.
New Features
- AES67
- Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
- Packet Bridge
- PEQ copy/paste and import/export options
Improvements
- Configuration
- PEQ tab added
- Revised templates for better out-of-the-box room coverage
- Presets
- "Default Settings" added as a preset
- Name of the active preset displays above the Preset drop-down
- "Clear Preset" option added to "Save As Preset"
- Improved auto position performance
- Device names can now begin with a number
- New commands strings
- Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
- General bug fixes
Known Issue
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- MXA910: User Guide | Command Strings
- MXA910 version 2.0.8 is compatible with MXA910 devices running version 2.0.8 and below, but it is recommended to update all devices used together to the same firmware version.
- To operate MXA910 version 2.0.8 with Dante™ Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate MXA910 version 2.0.8 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI4IN 2.0.7
- ANI4OUT 2.0.8
- MXA310 2.0.8
- Microflex Wireless 5.1.23
- ULXD4D/4Q 2.1.16
- SCM820 1.3.3
- Shure Update Utility 2.3.0.18
- Shure Web Device Discovery 1.1
Firmware
2.0.7
July 7, 2017
Zobacz wszystkie aktualizacje
New Features
- Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
- Packet Bridge
- PEQ import/export options
Improvements
- Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
- Configuration
- "Add/Remove Channel" button added on Coverage tab
- Presets
- "Default Settings" added as a preset
- Name of the active preset displays above the Preset drop-down
- "Clear Preset" option added to "Save As Preset"
- Device names can now begin with a number
- New command strings
- Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
- General bug fixes
Known Issues
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
- Encryption may become disabled in an extremely rare case after a power cycle of the device; users must re-enable encryption in the UI if this occurs.
- If Channel 1 is removed using the Add/Remove Channel feature and Channel 2, 3, or 4 is left as a single channel, then audio will not pass through the Automix Out channel. Channel 1 is the only channel that passes audio through the Automix Out channel.
Notes
- MXA310: User Guide | Command Strings
- MXA310 version 2.0.7 is compatible with MXA310 devices running version 2.0.7 and below, but it is recommended to update all devices used together to the same firmware version.
- To operate MXA310 version 2.0.7 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate MXA310 version 2.0.7 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI4IN 2.0.7
- ANI4OUT 2.0.8
- MXA910 2.0.8
- Microflex Wireless 5.1.23
- ULXD4D/4Q 2.1.16
- SCM820 1.3.3
- Shure Update Utility 2.3.0.18
- Shure Web Device Discovery 1.1
Firmware
2.0.8
July 7, 2017
Zobacz wszystkie aktualizacje
New Features
- Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
- Packet Bridge
- PEQ copy/paste and import/export options
Improvements
- Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
- Configuration
- PEQ tab added
- Presets
- "Default Settings" added as a preset
- Name of the active preset displays above the Preset drop-down
- "Clear Preset" option added to "Save As Preset"
- Device names can now begin with a number
- New commands strings
- Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
- General bug fixes
Known Issue
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- ANI4OUT: User Guide | Command Strings
- ANI4OUT version 2.0.8 is compatible with ANI4OUT devices running version 2.0.8 and below, but it is recommended to update all devices used together to the same firmware version.
- To operate ANI4OUT version 2.0.8 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate ANI4OUT version 2.0.8 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI4IN 2.0.7
- ANI4OUT 2.0.8
- MXA910 2.0.8
- Microflex Wireless 5.1.23
- ULXD4D/4Q 2.1.16
- SCM820 1.3.3
- Shure Update Utility 2.3.0.18
- Shure Web Device Discovery 1.1
Firmware
2.0.7
July 7, 2017
Zobacz wszystkie aktualizacje
New Features
- Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
- Packet Bridge
- PEQ copy/paste and import/export options
Improvements
- Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
- Configuration
- PEQ tab added
- Presets
- "Default Settings" added as a preset
- Name of the active preset displays above the Preset drop-down
- "Clear Preset" option added to "Save As Preset"
- Device names can now begin with a number
- New commands strings
- Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
- General bug fixes
Known Issue
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- ANI4IN: User Guide | Command Strings
- ANI4IN version 2.0.7 is compatible with ANI4IN devices running version 2.0.7 and below, but it is recommended to update all devices used together to the same firmware version.
- To operate ANI4IN version 2.0.7 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate ANI4IN version 2.0.7 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI4IN 2.0.7
- ANI4OUT 2.0.8
- MXA910 2.0.8
- Microflex Wireless 5.1.23
- ULXD4D/4Q 2.1.16
- SCM820 1.3.3
- Shure Update Utility 2.3.0.18
- Shure Web Device Discovery 1.1
Firmware
2.0.7
June 30, 2017
Zobacz wszystkie aktualizacje
New Features
- Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
- Packet Bridge
- PEQ import/export options
Improvements
- Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
- Configuration
- "Add/Remove Channel" button added on Coverage tab
- Presets
- "Default Settings" added as a preset
- Name of the active preset displays above the Preset drop-down
- "Clear Preset" option added to "Save As Preset"
- Device names can now begin with a number
- New command strings
- Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
- General bug fixes
Known Issues
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
- Encryption may become disabled in an extremely rare case after a power cycle of the device; users must re-enable encryption in the UI if this occurs.
- If Channel 1 is removed using the Add/Remove Channel feature and Channel 2, 3, or 4 is left as a single channel, then audio will not pass through the Automix Out channel. Channel 1 is the only channel that passes audio through the Automix Out channel.
Notes
- MXA310: User Guide | Command Strings
- MXA310 version 2.0.7 is compatible with MXA310 devices running version 2.0.7 and below, but it is recommended to update all devices used together to the same firmware version.
- To operate MXA310 version 2.0.7 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate MXA310 version 2.0.7 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI4IN 2.0.7
- ANI4OUT 2.0.8
- MXA910 2.0.8
- Microflex Wireless 5.1.23
- ULXD4D/4Q 2.1.16
- SCM820 1.3.3
- Shure Update Utility 2.3.0.18
- Shure Web Device Discovery 1.1
Firmware
2.0.8
June 30, 2017
Zobacz wszystkie aktualizacje
New Features
- Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
- Packet Bridge
- PEQ copy/paste and import/export options
Improvements
- Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
- Configuration
- PEQ tab added
- Presets
- "Default Settings" added as a preset
- Name of the active preset displays above the Preset drop-down
- "Clear Preset" option added to "Save As Preset"
- Device names can now begin with a number
- New commands strings
- Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
- General bug fixes
Known Issue
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- ANI4OUT: User Guide | Command Strings
- ANI4OUT version 2.0.8 is compatible with ANI4OUT devices running version 2.0.8 and below, but it is recommended to update all devices used together to the same firmware version.
- To operate ANI4OUT version 2.0.8 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate ANI4OUT version 2.0.8 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI4IN 2.0.7
- ANI4OUT 2.0.8
- MXA910 2.0.8
- Microflex Wireless 5.1.23
- ULXD4D/4Q 2.1.16
- SCM820 1.3.3
- Shure Update Utility 2.3.0.18
- Shure Web Device Discovery 1.1
Firmware
2.0.7
June 30, 2017
Zobacz wszystkie aktualizacje
New Features
- Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
- Packet Bridge
- PEQ copy/paste and import/export options
Improvements
- Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
- Configuration
- PEQ tab added
- Presets
- "Default Settings" added as a preset
- Name of the active preset displays above the Preset drop-down
- "Clear Preset" option added to "Save As Preset"
- Device names can now begin with a number
- New commands strings
- Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
- General bug fixes
Known Issue
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- ANI4IN: User Guide | Command Strings
- ANI4IN version 2.0.7 is compatible with ANI4IN devices running version 2.0.7 and below, but it is recommended to update all devices used together to the same firmware version.
- To operate ANI4IN version 2.0.7 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate ANI4IN version 2.0.7 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI4IN 2.0.7
- ANI4OUT 2.0.8
- MXA910 2.0.8
- Microflex Wireless 5.1.23
- ULXD4D/4Q 2.1.16
- SCM820 1.3.3
- Shure Update Utility 2.3.0.18
- Shure Web Device Discovery 1.1
Firmware
1.0.1
June 22, 2017
Zobacz wszystkie aktualizacje
NEW FEATURE
Initial release
NOTES
- To operate SBRC version 1.0.1 devices with other Shure software, see the following list of minimum versions:
- Wireless Workbench 6.12.1
- Shure Update Utility 2.3
Firmware
2.1.16
May 19, 2017
Zobacz wszystkie aktualizacje
NEW FEATURE
- Initial release
KNOWN ISSUE
- ULXD6/8 version 2.1.16 transmitters are not compatible with SystemOn 2.1.
NOTES
- ULXD6/8 User Guide
- To update firmware for ULXD6/8 transmitters with ULX-D or QLX-D receivers:
- Update receivers to the following minimum versions:
- ULXD4, ULXD4D, ULXD4Q Receivers 2.1.16
- QLXD4 Receivers 2.1.5 2
- Using Shure Update Utility, download ULXD6/8 transmitter firmware to the receivers.
- Using the FW Update menu on a receiver, update transmitters.
- Update receivers to the following minimum versions:
- ULXD6/8 transmitters can receive firmware updates while docked in an SBC450 or SBC850 Networked Charging Station.
- Place transmitters on charging station and ensure charging station is connected to the network.
- Launch Shure Update Utility to find firmware updates.
- Download updates and click Send Updates.
- To operate ULXD6/8 version 2.1.16 devices with other Shure networked systems and software, see the following list of minimum versions:
- ULX-D ULXD1/2 Transmitters and ULXD4, ULXD4D, ULXD4Q Receivers 2.1.16
- SBC450/850 Networked Charging Stations 2.1.16
- QLX-D QLXD4 Receivers 2.1.5
- Wireless Workbench 6.12.2
- Shure Update Utility 2.4
- ShurePlus Channels 1.3.1