Downloads

Archiwum oprogramowania i firmware

Filter by update type

Type

Release Title

Latest Version

Associated Products

Pobierz

Firmware
2.4.9
November 11, 2019 Zobacz wszystkie aktualizacje

Improvement 

  • Changed version number to allow all ULX-D devices in a configuration to have the same firmware version.

Known Issue 

  • SBC250/450/850 devices are not compatible with SystemOn 2.0-3.0.1

Notes 

  • SBC250 User Guide
  • SBC450/850 User Guide
  • To set up ULXD6/8 transmitters to receive firmware updates while docked in SBC250/450/850 Networked Charging Stations, follow these steps:
    1. Place transmitters on a charging station and ensure the charging station is connected to the network.
    2. Launch Shure Update Utility to find firmware updates.
    3. Download updates and select Send Updates.
  • To operate SBC250/450/850 version 2.4.9 with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD6/8 Transmitters and ULXD4/4D/4Q Receivers 2.4.9
    • QLX-D QLXD4 Receivers 2.3.8
    • Wireless Workbench 6.13.1
    • Shure Update Utility 2.4.6
    • ShurePlus Channels 1.4.2
Oprogramowanie
6.13.1
November 11, 2019 Zobacz wszystkie aktualizacje

New Features

OS-Level Notifications for Alerts: An enhancement to the Hardware Alerts and Interference Events features that allow users to receive notifications through their operating systems while Wireless Workbench is minimized. 

  • For Mac users, Wireless Workbench alerts and events will be displayed with an OS-level notification on the top right and will be viewable in the Notification Center.
  • For Windows users, Wireless Workbench alerts and events will be displayed with an OS-level notification on the bottom right in the system tray and will be viewable in the Action Center.

Improvements

  • Added support for macOS Catalina (10.15)

New Device and Frequency Band Support

  • Added support for new Shure frequency bands
    • H22 for PSM1000
    • H21 for PSM900
    • X56 and Z16 for Axient Digital
    • H14 and G15 for SVX
    • H10E and J11 for BLX
  • Added support for Sennheiser Digital 6000
  • Added support for AKG DMS800

Stability 

  • WWB no longer crashes when changing the frequency diversity (FD) mode in one scenario.
  • WWB no longer crashes when selecting certain frequency bands of ULX-D from Timeline.
  • WWB no longer crashes when deleting an offline device in one scenario.
  • WWB no longer crashes while changing the language with multiple property panels open.
  • WWB no longer crashes when resizing the Timeline channel chooser.
  • WWB no longer crashes while selecting AXT400 row from the inventory view.

Performance

  • Improved the speed of loading show files.
  • Improved the speed of loading the settings conflict dialog and to bring devices back online.
  • Improved the speed of creating channel strips in monitor views.
  • Improved CPU utilization when Timeline and Mini-Timelines are logging a large number of channels.

Networking

  • Made improvements to the network interface dialog to show actual network interface card names on macOS.
  • The network status in the bottom right corner of the main application window is now a button that will open the application network preferences.
  • Made improvements to the remote devices list in order to multi-select or unselect IP addresses.

Inventory

  • The transmitter power level for SLX master list bands are no longer blank for bands X7 and H19.
  • Aligned the AXT400 property panel and inventory properties sidebar to display properties in the same order.
  • Separated ULX-D scan lock and sync lock into two distinct properties accessible from the inventory properties side bar and properties panel.
  • Added PSM1000 IR presets to the Inventory sidebar and properties panel

Frequency Coordination 

  • Updated the offline TV Channels for the following countries:
    • Austria
    • Australia
    • Netherlands
    • Poland
    • United States
  • Added TV transmitter power level in TV Channels dialog.
  • Added the ability to resize and reorder columns in coordination chooser.
  • Show files now save check mark status of recent scans.

Monitoring

  • Added network status indications for ULX-D assigned to Dante domains.
  • Added Dante firmware, hardware, and bootloader versions to ULX-D and Axient Digital device information in their properties panels.
  • Axient Digital properties panels no longer have text getting cut off in the dropdown menu, and the vertical scroll bar is now displaying appropriately.
  • The audio level meter in channel strips and properties panel no longer freezes when audio overload hold is enabled in the application preferences.
  • Channels in frequency diversity (FD) modes are no longer overlaid with another channel strip in one scenario.

Timeline

  • Timeline files now include their view settings, allowing the files to be loaded with their saved view configuration.
  • The number of channels selected no longer resets to zero when the language is changed.
  • Mini-Timeline plots are no longer overlaid on each other in the auto view mode of the monitor view.
  • The PSM1000 left and right audio level data streams in Timeline no longer overlay one another.
  • Restarting a Timeline recording now preserves the Timeline settings in all frequency diversity (FD) modes.

General

  • Improved the user interface of the Zone Manager > Configure tab to highlight a zone when its column or row is selected.
  • Added an option in the Zone Manager > Configure tab to select all or deselect all spacing options for a selected zone.
  • Changed the name of the U.S. 600MHz Conversion Tool to Frequency Band Conversion Tool.
  • Improved button styling across the application.
Firmware
3.1.8

BUG FIXES

  • USB mute sync improvements
  • General bug fixes

NOTES

  • User Guide
  • Command Strings
  • To operate P300-IMX version 3.1.8 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX version 3.1.8 with other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANIUSB-MATRIX 3.1.6
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • MXA310 3.1.6
    • MXA910 4.0.12
    • Microflex Wireless 6.0.3
    • Shure Update Utility 2.4.5
    • Shure Web Device Discovery 1.2.5
App
2.6.2
September 23, 2019 Zobacz wszystkie aktualizacje

IMPROVEMENTS

  • Bug fixes

 

NOTES

Firmware
1.1.5
September 17, 2019 Zobacz wszystkie aktualizacje

Improvements

  • Improved reporting of battery errors

Notes

  • Command Strings
  • To operate SBRC version 1.1.5 with other Shure software, see the following list of minimum versions:
    • Shure Update Utility 2.4.5
    • Wireless Workbench 6.13.0
Firmware
2.0.9

These release notes cover the following models:

  • MXCWAPT Access Point Receiver
  • MXCW640 Wireless Conference Unit
  • MXCWNCS Networked Charging Station

 

IMPROVEMENT

  • Fixed a bug on the MXCWAPT where seat number-based TPCI commands fail to provide property updates after the APT is rebooted in manual registration mode

 

KNOWN ISSUES

MXCWAPT

  • Mute Concealment is not implemented in the interpretation channels. This feature will be available in the next release.

 

MXCWAPT Component GUI

  • General note: Clear browser cache (Shift+control+F5 on Windows) after the firmware update is done if you are already in the GUI at the time of the update.
  • Browser refresh may be required in the following situations:
    • On a Static/DHCP IP configuration change
    • If MXCW640s lose sync with GUI during registration, deregistration, or reboot
    • If GUI intermittently incorrectly shows some MXCW640s remained offline
  • There’s an intermittent issue where voting results are shown in the Display View even if the display icon is enabled through the Chairman View. Users may need to refresh their browser to resolve.
  • During some system factory resets, the APT’s reset initiation may be delayed ~2 minutes, in comparison to the MXCW640s.
  • Pinned seat numbers are not cleared after APT reboot in Auto+Open Connection Mode.
  • APT Help topics are not available in Thai, Turkish, and Lithuanian.
  • Some translated text is misaligned or may have extra, unnecessary punctuation or text.
  • Component GUIs take longer to load in Internet Explorer than Google Chrome, especially if used in a large system.

 

MXCW640

  • Some languages experience text issues.
  • Some text is not translated.

 

MXCWNCS

Users may need to refresh their browser on a Static/DHCP IP configuration change.

APT Help topics are not available in Thai, Turkish, and Lithuanian.

 

NOTES

  • User Guide
  • To use MXCW version 2.0.9 with other Shure software, reference the following list of minimum versions:
    • Shure Update Utility 2.4.5
    • Shure Web Device Discovery 1.2.5
    • Shure NFC Programming Application 1.0.3
Firmware
2.0.9

These release notes cover the following models:

  • MXCWAPT Access Point Receiver
  • MXCW640 Wireless Conference Unit
  • MXCWNCS Networked Charging Station

 

IMPROVEMENT

  • Fixed a bug on the MXCWAPT where seat number-based TPCI commands fail to provide property updates after the APT is rebooted in manual registration mode

 

KNOWN ISSUES

MXCWAPT

  • Mute Concealment is not implemented in the interpretation channels. This feature will be available in the next release.

 

MXCWAPT Component GUI

  • General note: Clear browser cache (Shift+control+F5 on Windows) after the firmware update is done if you are already in the GUI at the time of the update.
  • Browser refresh may be required in the following situations:
    • On a Static/DHCP IP configuration change
    • If MXCW640s lose sync with GUI during registration, deregistration, or reboot
    • If GUI intermittently incorrectly shows some MXCW640s remained offline
  • There’s an intermittent issue where voting results are shown in the Display View even if the display icon is enabled through the Chairman View. Users may need to refresh their browser to resolve.
  • During some system factory resets, the APT’s reset initiation may be delayed ~2 minutes, in comparison to the MXCW640s.
  • Pinned seat numbers are not cleared after APT reboot in Auto+Open Connection Mode.
  • APT Help topics are not available in Thai, Turkish, and Lithuanian.
  • Some translated text is misaligned or may have extra, unnecessary punctuation or text.
  • Component GUIs take longer to load in Internet Explorer than Google Chrome, especially if used in a large system.

 

MXCW640

  • Some languages experience text issues.
  • Some text is not translated.

 

MXCWNCS

Users may need to refresh their browser on a Static/DHCP IP configuration change.

APT Help topics are not available in Thai, Turkish, and Lithuanian.

 

NOTES

  • User Guide
  • To use MXCW version 2.0.9 with other Shure software, reference the following list of minimum versions:
    • Shure Update Utility 2.4.5
    • Shure Web Device Discovery 1.2.5
    • Shure NFC Programming Application 1.0.3
Firmware
2.0.9

These release notes cover the following models:

  • MXCWAPT Access Point Receiver
  • MXCW640 Wireless Conference Unit
  • MXCWNCS Networked Charging Station

 

IMPROVEMENT

  • Fixed a bug on the MXCWAPT where seat number-based TPCI commands fail to provide property updates after the APT is rebooted in manual registration mode

 

KNOWN ISSUES

MXCWAPT

  • Mute Concealment is not implemented in the interpretation channels. This feature will be available in the next release.

 

MXCWAPT Component GUI

  • General note: Clear browser cache (Shift+control+F5 on Windows) after the firmware update is done if you are already in the GUI at the time of the update.
  • Browser refresh may be required in the following situations:
    • On a Static/DHCP IP configuration change
    • If MXCW640s lose sync with GUI during registration, deregistration, or reboot
    • If GUI intermittently incorrectly shows some MXCW640s remained offline
  • There’s an intermittent issue where voting results are shown in the Display View even if the display icon is enabled through the Chairman View. Users may need to refresh their browser to resolve.
  • During some system factory resets, the APT’s reset initiation may be delayed ~2 minutes, in comparison to the MXCW640s.
  • Pinned seat numbers are not cleared after APT reboot in Auto+Open Connection Mode.
  • APT Help topics are not available in Thai, Turkish, and Lithuanian.
  • Some translated text is misaligned or may have extra, unnecessary punctuation or text.
  • Component GUIs take longer to load in Internet Explorer than Google Chrome, especially if used in a large system.

 

MXCW640

  • Some languages experience text issues.
  • Some text is not translated.

 

MXCWNCS

Users may need to refresh their browser on a Static/DHCP IP configuration change.

APT Help topics are not available in Thai, Turkish, and Lithuanian.

 

NOTES

  • User Guide
  • To use MXCW version 2.0.9 with other Shure software, reference the following list of minimum versions:
    • Shure Update Utility 2.4.5
    • Shure Web Device Discovery 1.2.5
    • Shure NFC Programming Application 1.0.3
App
2.6.2

Improvements

  • Bug fixes
  • Fixes for VoiceOver

Known Issues

  • A small percentage of users may receive a numerical error message while recording, such as “-1” or “66570.” These messages occur when there was an error writing to the device and are related to Apple’s new file system (APFS). One of these errors can occur even if your device has plenty of remaining storage. We recommend clearing up your device storage from the Settings screen, and if that doesn’t resolve the issues, doing a full restore from iTunes, consisting of backing up your device, wiping/restoring to factory settings, and restoring from the backup.
  • If you monitor your recordings with Bluetooth earphones, you may hear artifacts, such as noise, while monitoring. If this occurs, we recommend changing the sample rate of your recordings. Some products may produce artifacts at 44.1 kHz, while others may do so for 48 kHz recordings. Please keep in mind that even if you hear artifacts while monitoring, they will not be present in the recordings themselves.
  • When connected to iPad Pro via a USB-C cable, the MV88+ will pass audio and gain can be adjusted. However, the MOTIV apps will only display ‘external mic’, and the settings screen will not be available. Shure recommends using another device to configure the settings before using with iPad Pro. No adjustments can be made in real time (except gain) on the Shure MOTIV apps when using an iPad Pro.

Notes