Downloads

Archiwum oprogramowania i firmware

Filter by update type

Type

Release Title

Latest Version

Associated Products

Pobierz

Firmware
1.5.23

Improvements

  • General backend improvements

Known Issues

  • When one Unmute/Mute LED light color is set to White at 100% Brightness while the other Unmute/Mute light is set to Off, it may cause the button to freeze or the device mute state to spontaneously change. Lowering the device LED brightness alleviates this issue.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of MXA MUTE with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.35
    • ANIUSB-MATRIX 4.7.23
    • MXA310 4.7.8
    • MXA710 1.5.16
    • MXA910 4.7.13
    • MXA902 5.0.115
    • MXN5-C 1.5.21
    • P300 4.7.24
    • Shure Update Utility 2.8.3
    • Shure Web Device Discovery 1.2.17
Firmware
1.8.7
December 13, 2023 Zobacz wszystkie aktualizacje

Improvements

  • Bug fix related to battery warning shutdown behavior

Notes

  • User Guide
  • Shure recommends updating all PSM1000 devices in a configuration to the same firmware version
  • To operate this version of PSM1000 devices with other Shure networked systems and software, see the following list of recommended versions:
    • AXT600 2.1.41
    • Axient Digital 1.4.10
    • ULX-D 2.8.6
    • Shure Update Utility 2.8.3
    • ShurePlus Channels iOS 1.6.1
    • ShurePlus Channels Android 1.6.2
    • Wireless Workbench 6.15.4 or 7.0.0
Firmware
2.8.6
December 12, 2023 Zobacz wszystkie aktualizacje

Improvements

  • Support for added hardware revisions

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Known Issues

  • Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions

Notes

  • User Guides: ULXD4 | ULXD4D/Q
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD 2.8.6
    • Axient AXT600 Spectrum Manager 2.1.41
    • SBC250/450/850 Networked Charging Stations 2.8.6
    • Shure Update Utility 2.8.3
    • ShurePlus Channels iOS 1.6.1
    • ShurePlus Channels Android 1.6.2
    • Wireless Workbench 6.15.4 or 7.0.0
Firmware
2.8.6
December 12, 2023 Zobacz wszystkie aktualizacje

Improvements

  • Support for added hardware revisions

Important

  • ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
  • ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
  • After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version. 

Known Issues

  • Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions

Notes

  • User Guides: ULXD4 | ULXD4D/Q
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD 2.8.6
    • Axient AXT600 Spectrum Manager 2.1.41 
    • SBC250/450/850 Networked Charging Stations 2.8.6
    • Shure Update Utility 2.8.3
    • ShurePlus Channels iOS 1.6.1
    • ShurePlus Channels Android 1.6.2
    • Wireless Workbench 6.15.4 or 7.0.0
Firmware
2.8.6
December 12, 2023 Zobacz wszystkie aktualizacje

Improvements

  • Support for added hardware revisions

Important

  • ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
  • ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
  • After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Known Issues

  • Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions

Notes

  • User Guides: ULXD4 | ULXD4D/Q
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD 2.8.6
    • Axient AXT600 Spectrum Manager 2.1.41
    • SBC250/450/850 Networked Charging Stations 2.8.6
    • Shure Update Utility 2.8.3
    • ShurePlus Channels iOS 1.6.1
    • ShurePlus Channels Android 1.6.2
    • Wireless Workbench 6.15.4 or 7.0.0
Firmware
2.8.6
December 12, 2023 Zobacz wszystkie aktualizacje

Improvements

  • Support for added hardware revisions

Notes

  • User Guide
  • Information about the hardware revision is displayed in the UTILITY > VERSION menu
  • To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD 2.8.6
    • Axient AXT600 Spectrum Manager 2.1.41
    • Shure Update Utility 2.8.3
    • ShurePlus Channels iOS 1.6.1
    • ShurePlus Channels Android 1.6.2
    • Wireless Workbench 6.15.4 or 7.0.0
Firmware
2.8.6
December 12, 2023 Zobacz wszystkie aktualizacje

Improvements

  • Support for added hardware revisions

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Notes

  • User Guide
  • To update firmware for ULXD6/8 transmitters with ULX-D or QLX-D receivers:
    1. Update receivers to the following minimum versions:
      • ULXD4, ULXD4D, and ULXD4Q Receivers 2.1.16 or higher
      • QLXD4 Receivers 2.1.5 or higher
    2. Using Shure Update Utility, download ULXD6/8 transmitter firmware to the receivers.
    3. Using the FW Update menu on a receiver, update transmitters.
  • To update ULXD6/8 transmitters firmware while they are docked in an SBC250/450/850 Networked Charging Station:
    1. Place transmitters on charging station and ensure charging station is connected to the network.
    2. Launch Shure Update Utility to find firmware updates.
    3. Download updates and select Send Updates.
  • To operate this version of ULXD6/8 devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD 2.8.6
    • QLXD 2.7.1
    • SBC250/450/850 Networked Charging Stations 2.8.6
    • Shure Update Utility 2.8.3
    • ShurePlus Channels iOS 1.6.1
    • ShurePlus Channels Android 1.6.2
    • Wireless Workbench 6.15.4 or 7.0.0
Firmware
2.8.6
December 12, 2023 Zobacz wszystkie aktualizacje

Notes 

  • User Guides: SBC250 | SBC450/850
  • To set up ULXD6/8 transmitters to receive firmware updates while docked in SBC250/450/850 Networked Charging Stations, follow these steps:
    1. Place transmitters on a charging station and ensure the charging station is connected to the network.
    2. Launch Shure Update Utility to find firmware updates.
    3. Download updates and select Send Updates.
  • To operate this version of SBC250/450/850 with other Shure networked systems and software, see the following list of recommended versions:
    • ULX-D 2.8.6
    • Shure Update Utility 2.8.3
    • Wireless Workbench 6.15.4 or 7.0.0
Firmware
2.7.1
December 11, 2023 Zobacz wszystkie aktualizacje

Recommendation

  • Update all QLX-D devices in a configuration to the same firmware version.

Important

  • QLX-D 2.X firmware versions are incompatible with 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Support for added hardware revisions

Notes

  • User Guide
  • To operate QLX-D transmitters with ULX-D receivers and ULX-D transmitters with QLX-D receivers, all devices must be on version 2.X firmware or later.
  • To operate this version of QLX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • AXT600 Axient Spectrum Manager 2.1.41
    • PSM1000 P10T Transmitters 1.8.6
    • ULX-D 2.7.6
    • Wireless Workbench 6.15.4 or 7.0.0
    • Shure Update Utility 2.8.3
    • ShurePlus Channels iOS 1.6.1
    • ShurePlus Channels Android 1.6.2
Firmware
2.7.1
December 11, 2023 Zobacz wszystkie aktualizacje

Recommendation

  • Update all QLX-D devices in a configuration to the same firmware version.

Important

  • QLX-D 2.X firmware versions are incompatible with 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Support for added hardware revisions

Notes

  • User Guide
  • To operate QLX-D transmitters with ULX-D receivers and ULX-D transmitters with QLX-D receivers, all devices must be on version 2.X firmware or later.
  • To operate this version of QLX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • AXT600 Axient Spectrum Manager 2.1.41
    • PSM1000 P10T Transmitters 1.8.6
    • ULX-D 2.7.6
    • Wireless Workbench 6.15.4 or 7.0.0
    • Shure Update Utility 2.8.3
    • ShurePlus Channels iOS 1.6.1
    • ShurePlus Channels Android 1.6.2