Downloads

Archiwum oprogramowania i firmware

Filter by update type

Type

Release Title

Latest Version

Associated Products

Pobierz

Firmware
7.1.4
February 12, 2024 Zobacz wszystkie aktualizacje

Improvements

  • Support for new MXCWAPT hardware components
  • Bug fixes

Known Issues

MXCWAPT

  • MXCWAPT FW update with older versions of SUU may result in SUU reporting a false update failure, when update was actually successful.  If this occurs, verify FW on APT via GUI or LCD.
  • When downgrading from FW 7.0, to FW4 or lower, the process has to be done in two separate steps: First upload the MXCW640 FW to the APT via the SUU and downgrade the discussion units. Secondly downgrade the MXCWAPT from SUU.

MXCWAPT Component GUI

  • When running Windows-Version:1809, cannot access APT CGUI when opened via DNS Name applied directly to the browser search bar or with Shure Web Device Discovery Application shortcut. Opening APT CGUI via IP address works as designed.

MXCW640

  • MXCW640 Left/Right buttons incorrect LED indication when using FIFO conference mode with Dual-Delegate or while identifying units while in Request List.
  • In very rare occasions, MXCW640 touch screen will not respond to screen touch.  Resolved by power cycling unit.

TPCI

  • Once MXCW640s are set to Ambient Role, unit will no longer respond to TPCI strings that are indexed based off of seat number.
  • Once MXCW640s are set to Ambient Role, and rebooted, unit will no longer send TPCI strings when changing role to other than Ambient (Chairman, Delegate, Interpreter etc). Resolved by power cycling the unit, while not in Ambient role.
  • Rare TPCI errors reporting a single MXCW640’s when transitioning roles from Ambient. Resolved by restarting unit.

Software

  • Shure Discovery Application missing MXCWAPT AES67 indication.

Notes

  • User Guide
  • To operate this version of MXCW with other Shure systems and software, see the following list of recommended versions:
    • Shure Update Utility 2.8.4
    • Shure Web Device Discovery 1.2.17
    • Shure NFC Programming Application 1.0.3
Firmware
7.1.4
February 12, 2024 Zobacz wszystkie aktualizacje

Improvements

  • Support for new MXCWAPT hardware components
  • Bug fixes

Known Issues

MXCWAPT

  • MXCWAPT FW update with older versions of SUU may result in SUU reporting a false update failure, when update was actually successful.  If this occurs, verify FW on APT via GUI or LCD.
  • When downgrading from FW 7.0, to FW4 or lower, the process has to be done in two separate steps: First upload the MXCW640 FW to the APT via the SUU and downgrade the discussion units. Secondly downgrade the MXCWAPT from SUU.

MXCWAPT Component GUI

  • When running Windows-Version:1809, cannot access APT CGUI when opened via DNS Name applied directly to the browser search bar or with Shure Web Device Discovery Application shortcut. Opening APT CGUI via IP address works as designed.

MXCW640

  • MXCW640 Left/Right buttons incorrect LED indication when using FIFO conference mode with Dual-Delegate or while identifying units while in Request List.
  • In very rare occasions, MXCW640 touch screen will not respond to screen touch.  Resolved by power cycling unit.

TPCI

  • Once MXCW640s are set to Ambient Role, unit will no longer respond to TPCI strings that are indexed based off of seat number.
  • Once MXCW640s are set to Ambient Role, and rebooted, unit will no longer send TPCI strings when changing role to other than Ambient (Chairman, Delegate, Interpreter etc). Resolved by power cycling the unit, while not in Ambient role.
  • Rare TPCI errors reporting a single MXCW640’s when transitioning roles from Ambient. Resolved by restarting unit.

Software

  • Shure Discovery Application missing MXCWAPT AES67 indication.

Notes

  • User Guide
  • To operate this version of MXCW with other Shure systems and software, see the following list of recommended versions:
    • Shure Update Utility 2.8.4
    • Shure Web Device Discovery 1.2.17
    • Shure NFC Programming Application 1.0.3
Firmware
6.0.29
February 12, 2024 Zobacz wszystkie aktualizacje

Initial Release

 

Notes

  • User Guide
  • To operate this version of MXA901 with other Shure networked systems, see the following list of recommended versions:
    • Shure Update Utility 2.8.4
Firmware
2.8.7

NOTE: This update is for REV5 devices only.

Improvements

  • Support for added hardware revisions

Important

  • ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
  • ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
  • After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Known Issues

  • Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions

Notes

  • User Guides: ULXD4 | ULXD4D/Q
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD 2.8.6
    • Axient AXT600 Spectrum Manager 2.1.41
    • SBC250/450/850 Networked Charging Stations 2.8.6
    • Shure Update Utility 2.8.4
    • ShurePlus Channels iOS 1.6.1
    • ShurePlus Channels Android 1.6.2
    • Wireless Workbench 6.15.4 or 7.0.1
Firmware
2.8.7

NOTE: This update is for REV5 devices only.

Improvements

  • Support for added hardware revisions

Important

  • ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
  • ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
  • After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Known Issues

  • Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions

Notes

  • User Guides: ULXD4 | ULXD4D/Q
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD 2.8.6
    • Axient AXT600 Spectrum Manager 2.1.41
    • SBC250/450/850 Networked Charging Stations 2.8.6
    • Shure Update Utility 2.8.4
    • ShurePlus Channels iOS 1.6.1
    • ShurePlus Channels Android 1.6.2
    • Wireless Workbench 6.15.4 or 7.0.1
Firmware
1.2.13

Important

  • This launch day update is for SLXD3 Plug-On Digital Wireless Transmitters only

Notes

  • User Guide
  • To operate this version of SLX-D with other Shure networked systems, see the following list of recommended versions:
    • Wireless Workbench 6.15.4 or 7.0.1
    • Shure Update Utility 2.8.4
Firmware
1.2.13

Important

  • This launch day update is for SLXD5 Single-Channel Portable Digital Wireless Receivers only

Notes

  • User Guide
  • To operate this version of SLX-D with other Shure networked systems, see the following list of recommended versions:
    • Wireless Workbench 6.15.4 or 7.0.1
    • Shure Update Utility 2.8.4
Firmware
4.7.24

Improvements

  • General backend improvements

Known Issues

  • Shure Audio Encryption is not backward compatible; all devices must be on version 4.1+ firmware to use this feature
  • P300 Shure Audio Encryption sometimes has a brief crackling sound on audio after muting
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.
  • P300 firmware periodically adds new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of P300-IMX with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300-IMX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300-IMX with other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.35
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.23
    • MXA310 4.7.8
    • MXA710 1.5.16
    • MXA910 4.7.13
    • MXN5-C 1.5.21
    • MXA-MUTE 1.5.23
    • Microflex Wireless 10.0.8
    • Shure Update Utility 2.8.3
    • Shure Web Device Discovery 1.2.17
Firmware
4.7.24

Improvements

  • General backend improvements

Known Issues

  • Shure Audio Encryption is not backward compatible; all devices must be on version 4.1+ firmware to use this feature
  • P300 Shure Audio Encryption sometimes has a brief crackling sound on audio after muting
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.
  • P300 firmware periodically adds new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of P300-IMX with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300-IMX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300-IMX with other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.35
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.23
    • MXA310 4.7.8
    • MXA710 1.5.16
    • MXA910 4.7.13
    • MXN5-C 1.5.21
    • MXA-MUTE 1.5.23
    • Microflex Wireless 10.0.8
    • Shure Update Utility 2.8.3
    • Shure Web Device Discovery 1.2.17
Firmware
4.7.23

Improvements

  • General backend improvements

Known Issues

  • Pop noise is triggered when the channel is unrouted in Dante controller with encryption enabled
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported.
  • Shure Audio Encryption is not backward compatible; all devices must be on version 4.1 firmware or newer to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)
  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by a reboot

Notes

  • User Guide
  • Command Strings
  • This version of ANIUSB-MATRIX is compatible with ANIUSB-MATRIX devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate this version of ANIUSB-MATRIX with Dante Controller, reference the following minimum versions
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of ANIUSB-MATRIX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of ANIUSB-MATRIX with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.35
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • MXA310 4.7.8
    • MXA910 4.7.13
    • Microflex Wireless 10.0.8
    • P300 4.7.24
    • ULXD4D/4Q 2.8.6
    • SCM820 1.4.3
    • Shure Update Utility 2.8.3
    • Shure Web Device Discovery 1.2.17