Firmware
6.0.23
February 29, 2024
Zobacz wszystkie aktualizacje
Improvements
- Enhancements to support Designer 6.0.0
- Additional hardware support
Known Issues
- An 802.1X re-authorization request interrupts a firmware update and causes it to fail
- Workaround: restarting the update will resolve the problem
- AES67 support is only available on UltimoX hardware
- MXA310 devices manufactured as of July 2017 are compatible with AES67
- In AES67 mode - Audio does not pass after changing Dante Device name, followed by a reboot
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
- The Mute Control Function command string response is incorrect when using <GET 0 ALL>
- When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
- When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > Response | Actual MUTE_CONTROL_FUNC |
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC > | LOCAL |
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL > | LOGIC |
< REP MUTE_BUTTON OFF > | DISABLED |
Notes
- User Guide
- Command Strings
- To operate this version of MXA310 with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (Mac OS X)
- Updating all devices used together to the same firmware version is recommended.
- To operate this version of MXA310 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
- Designer 6.0.0
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA710 6.0.24
- MXA910 6.0.24
- MXA920 6.0.38
- MXA901 6.0.39
- MXA902 6.0.32
- MXN5-C 6.0.17
- MXA-MUTE 6.0.25
- MXW 10.0.X
- P300 6.0.38
- SCM820 1.4.3
- Shure Update Utility 2.8.4
- Shure Web Device Discovery 1.2.17
Firmware
6.0.44
February 29, 2024
Zobacz wszystkie aktualizacje
Improvements
- Enhancements to support Designer 6.0.0
- Additional hardware support
Known Issues
- An 802.1X re-authorization request interrupts a firmware update and causes it to fail
- Workaround: restarting the update will resolve the problem
- Pop noise is triggered when the channel is unrouted in Dante controller with encryption enabled
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported.
- In AES67 mode - Audio does not pass after changing Dante Device name, followed by a reboot
Notes
- User Guide
- Command Strings
- To operate this version of ANIUSB-MATRIX with Dante Controller, reference the following minimum versions
- v3.10.2.4 (Windows)
- v3.10.2.3 (macOS)
- To operate this version of ANIUSB-MATRIX with Microsoft Teams, reference the following minimum versions:
- Microsoft Teams Desktop: 1.3.00.24755
- Microsoft Teams Rooms: 4.6.20.0
- To operate this version of ANIUSB-MATRIX with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
- Designer 6.0.0
- ANI22/ANI4IN/ANI4OUT 6.0.41
- MXA310 6.0.23
- MXA910 6.0.24
- MXA920 6.0.38
- MXA901 6.0.39
- MXA902 6.0.32
- MXW 10.0.X
- P300 6.0.38
- ULXD4D/4Q 2.8.7
- SCM820 1.4.3
- Shure Update Utility 2.8.4
- Shure Web Device Discovery 1.2.17
Firmware
6.0.41
February 29, 2024
Zobacz wszystkie aktualizacje
Improvements
- Enhancements to support Designer 6.0.0
- Additional hardware support
Known Issues
- AES67 support is only available on UltimoX hardware
- ANI4OUT devices manufactured as of January 2018 are compatible with AES67
- In AES67 mode - Audio does not pass after changing Dante Device name, followed by a reboot
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- User Guide
- Command Strings
- To operate this version of ANI4OUT with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (Mac OS X)
- Updating all devices used together to the same firmware version is recommended.
- To operate this version of ANI4OUT with other Shure networked systems, reference the following list of recommended versions supported:
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA310 6.0.23
- MXA910 6.0.24
- MXA920 6.0.38
- MXA901 6.0.39
- MXA902 6.0.32
- MXW 10.0.X
- P300 6.0.38
- ULXD4D/4Q 2.8.7
- SCM820 1.4.3
- Shure Update Utility 2.8.4
- Shure Web Device Discovery 1.2.17
Firmware
6.0.41
February 29, 2024
Zobacz wszystkie aktualizacje
Improvements
- Enhancements to support Designer 6.0.0
- Additional hardware support
Known Issues
- AES67 support is only available on UltimoX hardware
- ANI4OUT devices manufactured as of January 2018 are compatible with AES67
- In AES67 mode - Audio does not pass after changing Dante Device name, followed by a reboot
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- User Guide
- Command Strings
- To operate this version of ANI4OUT with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (Mac OS X)
- Updating all devices used together to the same firmware version is recommended.
- To operate this version of ANI4OUT with other Shure networked systems, reference the following list of recommended versions supported:
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA310 6.0.23
- MXA910 6.0.24
- MXA920 6.0.38
- MXA901 6.0.39
- MXA902 6.0.32
- MXW 10.0.X
- P300 6.0.38
- ULXD4D/4Q 2.8.7
- SCM820 1.4.3
- Shure Update Utility 2.8.4
- Shure Web Device Discovery 1.2.17
Firmware
6.0.41
February 29, 2024
Zobacz wszystkie aktualizacje
Improvements
- Enhancements to support Designer 6.0.0
- Additional hardware support
Known Issues
- AES67 support is only available on UltimoX hardware
- ANI4IN devices manufactured as of January 2018 are compatible with AES67
- In AES67 mode - Audio does not pass after changing Dante Device name, followed by a reboot
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- User Guide
- Command Strings
- To operate this version of ANI4IN with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (Mac OS X)
- Updating all devices used together to the same firmware version is recommended.
- To operate this version of ANI4IN with other Shure networked systems, reference the following list of recommended versions supported:
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA310 6.0.23
- MXA910 6.0.24
- MXA920 6.0.38
- MXA901 6.0.39
- MXA902 6.0.32
- MXW 10.0.X
- P300 6.0.38
- ULXD4D/4Q 2.8.7
- SCM820 1.4.3
- Shure Update Utility 2.8.4
- Shure Web Device Discovery 1.2.17
Firmware
6.0.41
February 29, 2024
Zobacz wszystkie aktualizacje
Improvements
- Enhancements to support Designer 6.0.0
- Additional hardware support
Known Issues
- AES67 support is only available on UltimoX hardware
- ANI4IN devices manufactured as of January 2018 are compatible with AES67
- In AES67 mode - Audio does not pass after changing Dante Device name, followed by a reboot
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- User Guide
- Command Strings
- To operate this version of ANI4IN with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (Mac OS X)
- Updating all devices used together to the same firmware version is recommended.
- To operate this version of ANI4IN with other Shure networked systems, reference the following list of recommended versions supported:
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA310 6.0.23
- MXA910 6.0.24
- MXA920 6.0.38
- MXA901 6.0.39
- MXA902 6.0.32
- MXW 10.0.X
- P300 6.0.38
- ULXD4D/4Q 2.8.7
- SCM820 1.4.3
- Shure Update Utility 2.8.4
- Shure Web Device Discovery 1.2.17
Firmware
6.0.41
February 29, 2024
Zobacz wszystkie aktualizacje
Improvements
- Enhancements to support Designer 6.0.0
- Additional hardware support
Known Issues
- Security Certificates:
- Certificates must be in the PEM (Privacy Enhanced Mail) format
- Certificates must be X.509 certificates and keys: PEM (Base64 ASCII), and DER (binary)
- The CUI may become unresponsive after a firmware update
- Workaround: Try clearing the cache on your browser to re-assert the connection. Please check your web browser for instructions on how to clear the browser cache. A common method of clearing the cache of a browser is Ctrl SHIFT R .
- Browser disconnection: Web browsers connected to our devices maybe disconnected after one hour if no user activity is detected. Refresh the browser to re-establish the connection.
- In AES67 mode - Audio does not pass after changing Dante Device name, followed by a reboot
- ANI22-XLR reverses absolute phase from Analog in to Dante out – workaround is to enable “Invert polarity” for Dante Output
- When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
Notes
- User Guide
- Command Strings
- To operate this version of ANI22 with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (macOS)
- Updating all devices used together to the same firmware version is recommended.
- To operate this version of ANI22 with other Shure networked systems, reference the following list of recommended versions supported:
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA310 6.0.23
- MXA910 6.0.24
- MXA920 6.0.38
- MXA901 6.0.39
- MXA902 6.0.32
- MXW 10.0.X
- ULXD4D/4Q 2.8.7
- SCM820 1.4.3
- Shure Update Utility 2.8.4
- Shure Web Device Discovery 1.2.17
Firmware
1.2.58
February 26, 2024
Zobacz wszystkie aktualizacje
New Features
- (Shure) Updated band support to include:
- G53, G54, G55, G57+, G62, G63, H54
- K53, K54, K58, L60,
- X51
- (Shure/Q5X) Added Talk Switch functionality to supporting form factors
- (Q5X) Added support for configurable UI elements on supporting form factors:
- Enable/Disable ON/OFF button
- Enable/Disable heartbeat indicator
- LED brightness control
- Configurable Aux Button functionality
Improvements
- (Q5X) Improved battery parameter tracking
- (Q5X) General Improvements
Notes
- To install Q5X firmware on devices:
- Download Q5X firmware from Shure Update Utility
- Connect to the AD4D, AD4Q, or ADX5D receiver, and in the Hosted Tx section, select Q5XTx 1.2.56
- Send the update to the receiver
- Use IR Sync to update the transmitter firmware
- AD4D and AD4Q can only host one transmitter firmware image at a time; if you also need to update Axient Digital transmitters, please repeat the above process, but select an ADTx firmware version.
- To operate this version of Q5X with Shure systems and software, see the following list of recommended versions:
- Axient Digital Receivers 1.4.15
- ADX5D 1.4.15
- Shure Update Utility 2.8.4
- Distributed by Shure. AquaMic™, CoachMic™, and PlayerMic® and MicCommander™ are Q5X products. For support and service, please visit www.q5x.com.
Firmware
1.4.15
February 26, 2024
Zobacz wszystkie aktualizacje
Recommendation
- Update all Axient Digital devices in a configuration to the same firmware version
Improvements
- Bug fixes
Notes
- User Guide
- To operate this version of AD610 with other Shure systems and software, see the following list of recommended versions:
- Axient Digital Transmitters 1.4.15
- Axient Digital Receivers 1.4.15
- ADX5D 1.4.15
- ShurePlus Channels iOS 1.6.1
- ShurePlus Channels Android 1.6.2
- Shure Update Utility 2.8.4
- Wireless Workbench 6.15.4 or 7.0.1
Firmware
1.4.15
February 26, 2024
Zobacz wszystkie aktualizacje
Recommendation
- Update all Axient Digital devices in a configuration to the same firmware version
Improvements
- Bug fixes
Notes
- User Guides: AD1 | ADX1 | ADX1M | AD2 | ADX2 | ADX2FD | AD3 | ADX3
- To operate this version of Axient Digital transmitters with other Shure systems and software, see the following list of recommended versions:
- Axient Digital Receivers 1.4.15
- ShurePlus Channels iOS 1.6.1
- ShurePlus Channels Android 1.6.2
- Shure Update Utility 2.8.4
- Wireless Workbench 6.15.4 or 7.0.1