Downloads

Archiwum oprogramowania i firmware

Filter by update type

Type

Release Title

Latest Version

Associated Products

Pobierz

Firmware
1.1.62

Improvement

  • Enforcement of Access Control via Wireless Workbench to devices with remote connection has been fixed.

Notes

  • User Guide
  • To operate AD610 version 1.1.62 devices with other Shure systems and software, see the following list of minimum versions:
    • Axient Digital AD1/2 and ADX1/1M/2 Transmitters 1.1.62
    • Axient Digital AD4D/Q Receivers 1.1.62
    • Axient AXT400 Receiver 2.1.11
    • Axient AXT100/200 2.1.11
    • SBRC Shure Battery Rack Charger 1.1.2
    • Shure Update Utility 2.4.3
    • ShurePlus Channels 1.4.2
    • Wireless Workbench 6.12.6
Firmware
1.1.62

New Feature

  • Initial firmware for ADX2FD

Improvements

  • Network browser improvements to discover new Shure product variants.
  • Improved TCPI commands to include RSSI information below -120dBm.
  • Enforcement of Access Control via Wireless Workbench to devices with remote connection has been fixed.

Notes

  • User Guide
  • Command Strings
  • AD4Q version 1.1.62 is compatible with AD4Q devices on version 1.1.62 and below, but it is recommended to update all devices used together to the same firmware version.
  • To operate AD4D version 1.1.62 devices with other Shure systems and software, see the following list of minimum versions:
    • Axient Digital AD1/2 and ADX1/1M/2 Transmitters 1.1.62
    • Axient Digital AD4D/Q Receivers 1.1.62
    • Axient AXT600 Spectrum Manager 2.1.22
    • SBRC Shure Battery Rack Charger 1.1.2
    • Shure Update Utility 2.4.3
    • ShurePlus Channels 1.4.2
    • Wireless Workbench 6.12.6
Firmware
1.1.62

New Feature

  • Initial firmware for ADX2FD

Improvements

  • Network browser improvements to discover new Shure product variants.
  • Improved TCPI commands to include RSSI information below -120dBm.
  • Enforcement of Access Control via Wireless Workbench to devices with remote connection has been fixed

Notes

  • User Guide
  • Command Strings
  • AD4D version 1.1.62 is compatible with AD4D devices on version 1.1.62 and below, but it is recommended to update all devices used together to the same firmware version.
  • To operate AD4D version 1.1.62 devices with other Shure systems and software, see the following list of minimum versions:
    • Axient Digital AD1/2 and ADX1/1M/2 Transmitters 1.1.62
    • Axient Digital AD4D/Q Receivers 1.1.62
    • Axient AXT600 Spectrum Manager 2.1.22
    • SBRC Shure Battery Rack Charger 1.1.2
    • Shure Update Utility 2.4.3
    • ShurePlus Channels 1.4.2
    • Wireless Workbench 6.12.6
Firmware
1.1.62

New Features

  • Initial firmware for ADX2FD
  • Safe Start menu
    • The Safe Start menu powers on the unit with the RF muted to prevent interference to other nearby transmitters. Next, a Safe Start menu appears to quickly configure the RF and the available lock options.
    • To initiate the Safe Start menu for AD1, AD2, ADX1, ADX2, and ADX2FD, hold down EXIT during boot up. For ADX1M, hold down EXIT + UP during boot up.

Improvements

  • Updated the 794 – 806 MHz (R52) frequency band for Israel
  • Optimized performance of automatic interference avoidance for ADX2FD in the G56 and K56 bands when operating in Frequency Diversity combining mode.

Notes

  • User Guides: AD1 | AD2 | ADX1 | ADX1M | ADX2 | ADX2FD
  • AD1/2 and ADX1/1M/2 version 1.1.62 is compatible with devices on version 1.1.62 and below, but it is recommended to update all devices used together to the same firmware version.
  • To operate AD1/2 and ADX1/1M/2 version 1.1.62 devices with other Shure systems and software, see the following list of minimum versions:
    • Axient Digital AD1/2 and ADX1/1M/2 Transmitters 1.1.62
    • Axient Digital AD4D/Q Receivers 1.1.62
    • Axient AXT600 Spectrum Manager 2.1.22
    • SBC240/840/840M Chargers 1.1.62
    • SBRC Shure Battery Rack Charger 1.1.2
    • Shure Update Utility 2.4.3
    • ShurePlus Channels 1.4.2
    • Wireless Workbench 6.12.6
Firmware
3.1.5

Improvements

  • Compatibility with Designer 3.1 System Configuration Software
  • Mute sync with Skype for Business (PC) and Zoom (PC and Mac)
  • Improved template values for Mic Input Gain, AGC Target, Automix settings, and Compressor Threshold for MXA310, MXA910, ANI4IN, MXW6, and MXW8
  • Improved initial USB speaker volume and sample rate settings
  • Improved Windows 7 media playback over USB
  • Hardware LED Metering and Clip Improvements
  • Bug fixes

Notes

  • User Guide
  • Command Strings
  • To operate P300-IMX version 3.1.5 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX version 3.1.5 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.18
    • ANIUSB-MATRIX 3.1.5
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • MXA310 3.1.5
    • MXA910 3.1.5
    • Microflex Wireless 6.0.3
    • Shure Update Utility 3.4.2
    • Shure Web Device Discovery 1.2.5
Firmware
3.1.5

Recommendation

Update all MXA910 devices in a configuration to the same firmware version.

Improvements

Known Issues

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 3.1 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).

Notes

  • User Guide
  • New Demo Web UI
  • Command Strings
  • MXA910 version 3.1.5 is compatible with MXA310 devices running version 3.1.5 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA910 version 3.1.5 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA910 version 3.1.5 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 3.1.5
    • MXA310 3.1.5
    • Microflex Wireless 6.0.3
    • P300 IntelliMix® Audio Conferencing Processor 3.1.5
    • ULXD4D/4Q 2.2.24
    • SCM820 1.3.3
    • Shure Update Utility 2.4.3
    • Shure Web Device Discovery 1.2.5
Firmware
3.1.5

Recommendation

Update all MXA310 devices in a configuration to the same firmware version.

Improvements

Known Issues

  • After updating from version 2.X to 3.1.5, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 3.1 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
  • The Mute Control Function command string response is incorrect when using
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:

< GET 0 ALL > Response

Actual MUTE_CONTROL_FUNC

< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >

LOCAL

< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >

LOGIC

< REP MUTE_BUTTON OFF >

DISABLED

Notes

  • User Guide
  • New Demo Web UI
  • Command Strings
  • MXA310 version 3.1.5 is compatible with MXA310 devices running version 3.1.5 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 3.1.5 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 3.1.5 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 3.1.5
    • MXA910 3.1.5
    • Microflex Wireless 5.2.2
    • P300 IntelliMix® Audio Conferencing Processor 2.1.6
    • ULXD4D/4Q 2.2.24
    • SCM820 1.3.3
    • Shure Update Utility 2.4.2
    • Shure Web Device Discovery 1.2.5
Firmware
3.1.5

Recommendation

Update all MXA310 devices in a configuration to the same firmware version.

Improvements

Known Issues

  • After updating from version 2.X to 3.1.5, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 3.1 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
  • The Mute Control Function command string response is incorrect when using
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:

< GET 0 ALL > Response

Actual MUTE_CONTROL_FUNC

< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >

LOCAL

< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >

LOGIC

< REP MUTE_BUTTON OFF >

DISABLED

Notes

  • User Guide
  • New Demo Web UI
  • Command Strings
  • MXA310 version 3.1.5 is compatible with MXA310 devices running version 3.1.5 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 3.1.5 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 3.1.5 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 3.1.5
    • MXA910 3.1.5
    • Microflex Wireless 5.2.2
    • P300 IntelliMix® Audio Conferencing Processor 2.1.6
    • ULXD4D/4Q 2.2.24
    • SCM820 1.3.3
    • Shure Update Utility 2.4.2
    • Shure Web Device Discovery 1.2.5
Firmware
3.1.5

Recommendation

Update all Audio Network Interfaces in a configuration to the same firmware version.

Improvements

Known Issues

  • TCPI set 0 for input level switch also incorrectly changes the output level switch and vice versa.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 3.1 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).

Notes

  • User Guide
  • Command Strings
  • ANIUSB-MATRIX version 3.1.5 is compatible with ANIUSB-MATRIX devices running version 2.0.18 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate ANIUSB-MATRIX version 3.1.5 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate ANIUSB-MATRIX version 2.0.19 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • MXA310 3.1.5
    • MXA910 3.1.5
    • Microflex Wireless 6.0.3
    • P300 3.1.5
    • ULXD4D/4Q 2.2.23
    • SCM820 1.3.3
    • Shure Update Utility 2.4.3
    • Shure Web Device Discovery 1.2.5
Firmware
1.0.16

Initial Release

 

Known Issues

  • In a small number of instances, unplugging the MV88+ from an iPhone XS, XS Max, or XR can cause the phone to crash and reboot. This is due to an Apple bug that is being investigated and should be resolved in an upcoming iOS release.
  • In a small number of instances, the microphone will fail to be recognized by the MOTIV app, which will instead display "Built-In Mic" on the Mic Setup and Record screens and not record through the MV88+. Plugging the microphone into a PC or Mac, then plugging back into the mobile device will solve the issue.
  • When connected to iPad Pro via a USB-C cable, the MV88+ will pass audio and gain can be adjusted. However the MOTIV apps will only display ‘external mic’, and the settings screen will not be available. Shure recommends using another device to configure the settings before using with iPad Pro. No adjustments can be made in real time (except gain) on the Shure MOTIV apps when using an iPad Pro.

Notes