Downloads
Archiwum oprogramowania i firmware
Firmware
1.4.18
June 17, 2024
Zobacz wszystkie aktualizacje
Recommendation
- Update all Axient Digital devices in a configuration to the same firmware version
Improvements
- General backend improvements
Notes
- User Guides: AD1 | ADX1 | ADX1M | AD2 | ADX2 | ADX2FD | AD3 | ADX3
- To operate this version of Axient Digital transmitters with other Shure systems and software, see the following list of recommended versions:
- Axient Digital Receivers 1.4.15
- ShurePlus Channels iOS 1.6.1
- ShurePlus Channels Android 1.6.2
- Shure Update Utility 2.8.5
- Wireless Workbench 6.15.4 or 7.1.0
Firmware
6.1.64
May 30, 2024
Zobacz wszystkie aktualizacje
Improvements
- Added LLDP support for PoE+ negotiation for layered switches
- Device Mute behavior change
- Mute function now only mutes Automix output and leaves speaker input unmuted
- Loudspeaker can still be muted individually
- Command string to disable/enable AutoFocus is now available
Notes
Compatibility
- To operate this version of MXA920 with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (Mac OS X)
- To operate this version of MXA902 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
- Designer 6.1.0
- IntelliMix Room 6.1.0
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA310 6.0.23
- MXA710 6.0.27
- MXA910 6.0.24
- MXA920 6.0.39
- MXA901 6.0.39
- MXN5-C 6.0.17
- MXA-MUTE 6.0.25
- P300 6.0.41
- Shure Update Utility 2.8.5
- Shure Web Device Discovery 1.2.17
Firmware
6.0.39
May 22, 2024
Zobacz wszystkie aktualizacje
Improvements
- Bug fixes and general improvements
Known Issues
- The optional ARRAY_HEIGHT_OVERRIDE value sent via command strings must be resent upon power cycle
- If the ARRAY_HEIGHT_OVERRIDE command is used to set a height that is outside the valid range (122-914 cm), the command will not display an error but internally, the value will be rejected from being set
- Acoustic reflections from tables can sometimes be mistaken by the MXA920 as another source/talker location. The symptom is a second talker location coordinate set in front of and higher than the actual talker.
- Workaround: Place Coverage Areas to minimize pick-up of table surface reflections
- Channel Names are not set in the initial attempt of ‘push-to-Dante’. Dante interface resets when Device Name is set.
- Workaround: Channel Names are set on the 2nd attempt
- MXA920 LED does not stay on after a reboot if the light settings are set to Unmute = Blue, Mute = Red. Other light combinations work as expected after reboot.
- When a muted dynamic coverage area is moved when a dedicated coverage area has also been established, the mix output of the MXA920 has low-level audio from outside the dedicated coverage area limits.
- Workaround: Unmute and Mute the dynamic coverage area after a dynamic coverage area is moved
Notes
- User Guide
- Command Strings
- Note that Talker Position Events are published for talkers in a coverage area regardless of the mute status of the coverage area. To fully inform camera switching decision logic, subscribe to the Coverage Area Mute Status. See https://pubs.shure.com/command-strings for further information
- To operate this version of MXA920 with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (Mac OS X)
- To operate this version of MXA920 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
- Designer 6.0.0
- IntelliMix Room 4.2.0
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA310 6.0.23
- MXA710 6.0.27
- MXA910 6.0.24
- MXA901 6.0.39
- MXA902 6.0.33
- MXN5-C 6.0.17
- MXA-MUTE 6.0.25
- P300 6.0.41
- Shure Update Utility 2.8.5
- Shure Web Device Discovery 1.2.17
Firmware
6.0.39
May 22, 2024
Zobacz wszystkie aktualizacje
Improvements
- Bug fixes and general improvements
Known Issues
- The optional ARRAY_HEIGHT_OVERRIDE value sent via command strings must be resent upon power cycle
- If the ARRAY_HEIGHT_OVERRIDE command is used to set a height that is outside the valid range (122-914 cm), the command will not display an error but internally, the value will be rejected from being set
- Acoustic reflections from tables can sometimes be mistaken by the MXA920 as another source/talker location. The symptom is a second talker location coordinate set in front of and higher than the actual talker.
- Workaround: Place Coverage Areas to minimize pick-up of table surface reflections
- Channel Names are not set in the initial attempt of ‘push-to-Dante’. Dante interface resets when Device Name is set.
- Workaround: Channel Names are set on the 2nd attempt
- MXA920 LED does not stay on after a reboot if the light settings are set to Unmute = Blue, Mute = Red. Other light combinations work as expected after reboot.
- When a muted dynamic coverage area is moved when a dedicated coverage area has also been established, the mix output of the MXA920 has low-level audio from outside the dedicated coverage area limits.
- Workaround: Unmute and Mute the dynamic coverage area after a dynamic coverage area is moved
Notes
- User Guide
- Command Strings
- Note that Talker Position Events are published for talkers in a coverage area regardless of the mute status of the coverage area. To fully inform camera switching decision logic, subscribe to the Coverage Area Mute Status. See https://pubs.shure.com/command-strings for further information
- To operate this version of MXA920 with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (Mac OS X)
- To operate this version of MXA920 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
- Designer 6.0.0
- IntelliMix Room 4.2.0
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA310 6.0.23
- MXA710 6.0.27
- MXA910 6.0.24
- MXA901 6.0.39
- MXA902 6.0.33
- MXN5-C 6.0.17
- MXA-MUTE 6.0.25
- P300 6.0.41
- Shure Update Utility 2.8.5
- Shure Web Device Discovery 1.2.17
Firmware
1.2.0
May 15, 2024
Zobacz wszystkie aktualizacje
Improvements
- Backend improvements
Notes
- User Guide
- Firmware updates for MVX2U are available in MOTIV Mix and the MOTIV Desktop application
- MVX2U is compatible with the following recommended software versions:
- MOTIV Mix 1.1.1
- ShurePlus MOTIV Desktop 1.5.4
Firmware
2.0.19
May 15, 2024
Zobacz wszystkie aktualizacje
Improvements
- Bug fixes
Notes
- User Guide
- To operate this version of GLXD+ with other Shure systems and software, see the following list of recommended versions:
- GLXD1/2+ Transmitters 2.0.18
- GLXD4/4R/6+ Receivers 2.0.18
- Shure Update Utility 2.8.5
Firmware
6.0.33
May 1, 2024
Zobacz wszystkie aktualizacje
Improvements
- Bug fixes
Notes
- User Guide
- Command Strings
- To operate this version of MXA902 with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (Mac OS X)
- To operate this version of MXA902 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
- Designer 6.0.0
- IntelliMix Room 4.2.0
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA310 6.0.23
- MXA710 6.0.27
- MXA910 6.0.24
- MXA920 6.0.38
- MXA901 6.0.39
- MXN5-C 6.0.17
- MXA-MUTE 6.0.25
- P300 6.0.41
- Shure Update Utility 2.8.5
- Shure Web Device Discovery 1.2.17
Firmware
6.0.41
May 1, 2024
Zobacz wszystkie aktualizacje
Improvements
- Firmware update improvements
Known Issues
- P300 Shure Audio Encryption sometimes has a brief crackling sound on audio after muting
- P300 firmware periodically adds new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
Notes
- User Guide
- Command Strings
- To operate this version of P300 with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (macOS)
- To operate this version of P300 with Microsoft Teams, reference the following minimum versions:
- Microsoft Teams Desktop: 1.3.00.24755
- Microsoft Teams Rooms: 4.6.20.0
- To operate this version of P300 with other Shure networked systems, reference the following list of recommended versions supported:
- Designer 6.0.0
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA310 6.0.23
- MXA710 6.0.27
- MXA910 6.0.24
- MXN5-C 6.0.17
- MXA-MUTE 6.0.25
- MXW 10.0.X
- Shure Update Utility 2.8.5
- Shure Web Device Discovery 1.2.17
Firmware
6.0.41
May 1, 2024
Zobacz wszystkie aktualizacje
Improvements
- Firmware update improvements
Known Issues
- P300 Shure Audio Encryption sometimes has a brief crackling sound on audio after muting
- P300 firmware periodically adds new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
Notes
- User Guide
- Command Strings
- To operate this version of P300 with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (macOS)
- To operate this version of P300 with Microsoft Teams, reference the following minimum versions:
- Microsoft Teams Desktop: 1.3.00.24755
- Microsoft Teams Rooms: 4.6.20.0
- To operate this version of P300 with other Shure networked systems, reference the following list of recommended versions supported:
- Designer 6.0.0
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA310 6.0.23
- MXA710 6.0.27
- MXA910 6.0.24
- MXN5-C 6.0.17
- MXA-MUTE 6.0.25
- MXW 10.0.X
- Shure Update Utility 2.8.5
- Shure Web Device Discovery 1.2.17
Firmware
6.0.27
May 1, 2024
Zobacz wszystkie aktualizacje
Improvements
- Firmware update improvements
Notes
- User Guide
- Command Strings
- To operate this version of MXA710 with Dante Controller, reference the following minimum versions:
- v3.10.2.4 (Windows)
- v3.10.2.3 (Mac OS X)
- To operate this version of MXA710 with Shure software or other Shure networked systems, reference the following list of recommended versions supported:
- Designer 6.0.0
- ANI22/ANI4IN/ANI4OUT 6.0.41
- ANIUSB 6.0.44
- MXA310 6.0.23
- MXA910 6.0.24
- MXA920 6.0.38
- MXA901 6.0.39
- MXA902 6.0.33
- MXN5-C 6.0.17
- MXA-MUTE 6.0.25
- MXW 10.0.X
- P300 6.0.41
- ULXD4D/4Q 2.8.7
- SCM820 1.4.3
- Shure Update Utility 2.8.5
- Shure Web Device Discovery 1.2.17