6.3.34.15
June 22, 2016
Zobacz wszystkie aktualizacje
Maintenance Release
Important
- This version is a maintenance release for systems with CU 6005, CU 6010 and CU 6011 Central Units connecting to SW 6000 through RS232.
- This version is not for new installations
- This version can upgrade SW6000 from v6.0 to v6.3.21
- This version is compatible with SW6000 Software License file v1.7 only
- No SW6000 upgrade license is needed when upgrading from v6.0 to v6.3.21
- Upgrade from versions prior to v6.0 for system using CU 6005, CU 6010 or CU 6011 is not possible
Improvements
- CAA: A Conference log report with individual voting results now added to standard reports
- CUA: Revised ‘Present’ variable calculations (TotalPresent)
- CUI: Extended timeout window for receiving vote confirmations from CU from 3 to 10 seconds - with heavy login/logout activity vote confirmations may get delayed considerably
Bug Fixes
- CDA: Not automatically display the Logged In screen if configured as so
- CAA: Exception when creating a report when Windows is using comma as decimal separator
- CAA: Detailed delegate reports cannot be created
- CAA: Periodically not possible to login using chip card on CU
- CAA: Registration check issues potential deadlock warnings
- CUA: Individual/Group result screen incorrect when using proxy voting
- CUA: Mimic login name not cleared after delegate logout / move, in conference type Login using code on List.
- CUI: WebService error during re-voting on a agenda subject, causing a error in webservice log
Oprogramowanie
1.0.17
April 12, 2016
Zobacz wszystkie aktualizacje
New Feature
- Support for MXW2APT and MXWNCS2
Oprogramowanie
6.3.21
December 18, 2015
Zobacz wszystkie aktualizacje
Feature Release
Important
- This version is a feature release for v6.0 to v6.2.184 aimed for systems with CU 6005, CU 6010, CU 6011, CU 61xx and DIS_CCU Central Units
- CU 6005/CU 6010 and CU 6011 Central Units are supported with the following exceptions:
- Option to send messages to group of participants in addition to one/all participants” is not supported
- Reply feature is not supported
- CU 6005/CU 6010 or CU 6011 Central Units will not be supported on new feature releases of SW 6000.
- Version 6.3.21 is the last feature release supporting those central units.
- Maintenance releases branched out from 6.3.21 will be available to address possible bug fixes related to v6.3.21/CU 60xx.
New Features
- Option to send messages to group of participants in addition to one/all participants (not supported with CU 6005/CU 6010 or CU 6011)
- Received messages are displayed in a message list and kept until deleted or the user logs out or the conference is stopped
- A "Show on CUA" option for CDA screens in the CAA application is added. Used for disabling customised CDA screens which shall not be selectable in the CUA
- Support for WIN10 Operating System
- Custom reports are released in a separate zip file and are not part of the installation files
Improvements
CDA
- Customised Agenda: Added sorting option ‘Original’ in the filter option
- Customised Agenda: A parameter: ‘MaxItemsBefore’ has been added, which defines the number of items to show before the current subject
- Customised Agenda: TitleWithDescription shows now ShortDescription if Description does not exist
- Customised Agenda: Option to filter Agenda by ‘Level’
- Customised Outline is removed if no delegate picture is available
- Customised Request list Header are not glued to Request list anymore
- Command line parameter introduced: -Trace “Hittest”. This parameter enables i.e. scrolling for some lists in the CDA.
- Hiding hours count
- Labels updated : 10503 + 10515 + 12524
- Voting time animation are now by default turned off
CAA
- Inserting of seats on Mimic will now insert the seats sorted by Seat Number
- SW6000 is now getting the culture codes, which are available from Windows operation system, during installation
CUA
- Width of window and column in CUA-Display Control screen adjusted
- Database selection changed to be available only for technician
Bug Fixes
CDA
- Agenda import from Word : CDA only shows 1/2 line
- Blank page after display shifting
- Conference Display - update button not enabled
- Connection loss during conference
- Connection screen and custom screen mixed up
- Crashing during fast display shifting
- Custom display fading error
- Custom request list also shows speaker
- Editor cannot save background image to skin
- Group time is not removed when new timers are loaded
- Hide groups without time limits
- Hours are not shown on default
- Labels missing for alternative language
- Mimic, where the vertical dimension is larger than the horizontal dimension is not scaled correctly
- Old voting data is visible for about 1 second, before new data is shown
- Optimization: Slow agenda loading
- Page switching happens just after display shift
- Reconnect during display shift
- Skin editor - background color editor not working
- Slow updating with custom Group Sorting
- Speech-time counters are shown for groups with group speech time disabled
- The command line parameter, -mode offline - will not start up the CDA UI
CUA
- CUA/CAA MSMQ connections problems
- Ambient enable/disable control from CUA mimic are broken
- Duplicated delegate after re-arranging in-request queue, with CCU
- Exception after meeting date expiration
- Exception when a delegate login on a DC69
- Exception when selecting Database connection
- Exception when turning on chairman mic from CUA
- Microphone control get slow at times
- Multi Room not working at all.
- No microphone control in CUA when using Multi Room connections
- Registration and Voting button problems
- Registration error - sometimes all delegates are not logged in
- Reply not removed after delegate have been speaking on Podium
- Some delegates cannot vote periodically
- Termination at conference start
- Version info visible twice on front page
- Web service duplicate text error
- Will not start up if user.config AppData cannot be loaded
- With max. resolution - do not start up centred after installation
- Wrong Agenda title in Description view
- Error correction for group speech time adjustment
CUI
- CUI/CUA/Voting time is not set correctly during meetings
- Changing speech time configuration has no effect
- Command line parameter -Createlogs do not enable logging
- ‘Object Disposed Exception’ after 3-4 hours of static use
CAA
- Agenda import from Word - label missing
- Agenda import from Word - Long/short description error
- Cannot be closed - but has to be terminated with task manager very often
- Can't add new CDA
- CDA conference settings are stored, even if cancel is selected
- CDA configuration text error
- Deleting languages cause an SQL error
- Exception when deleting CAA Multi room configuration
- Incorrect Error message for Voting reports - if no Agenda have been active in conference
- Installation overwrites the default custom mimic image
- Label errors - Label ID 3119 and 3818
- Licensing issue with CDA Skin and List Format, license SW 6060
- Mimic configuration - search order arrow not visible
- Registration report cannot be created, if no subject has been set
- Remove or disable the 'No CUA Control' button
- Report generation very often cause CAA to crash
- Selecting a delegate picture of a wrong file format issues a wrong error message
- Setup/Equipment list: 'Zeroes' shown when units are rolling in with the window open
- Sorting missing in CDA configuration in Conference Options
- Voting Conference log report's cannot be generated
- Web service setup window - resize working incorrectly
- Weird default filename when importing labels
- Problem deleting old AO’s
Oprogramowanie
6.11.3
November 17, 2015
Zobacz wszystkie aktualizacje
New Features
- Added support for AXT100 Talk Switch capabilities. This update requires supporting Axient firmware (1.16)
Improvements
- Added compatibility with Windows 10 and Mac OS X El Capitan.
- Added support for new QLX-D bands in the ISM range: X52, X53, X54.
- Added support for new ULX-D band: Z16.
- In order to support this new band, the plot ranges in the Coordination Plot and Frequency Plot have been extended.
- Updated TV Data for Italy, Belgium, and the Netherlands.
Known Issues
- If you are running the Mac OS X Yosemite Operating System, be sure to run version 10.10.4 or later. Earlier beta versions of the Operating System are not supported.
- On Macs, when users open show files and launch the Frequency Analysis dialog (by checking the checkbox and pressing “Analyze”), the Frequency Coordination tab may stop responding to keyboard inputs (for example, editing or deleting frequencies with the keyboard). To work around this issue, select another tab in the application (e.g.: Inventory or Monitor) and then reselect the Frequency Coordination tab.
- SLX and ULX frequencies in Master List mode cannot be manually entered in the Coordination Workspace. They can, however, be coordinated and analyzed.
- When scanning with AXT400 receivers, the Band Preset value in the Live Scan Settings dialog does not always stay in sync with the currently selected band of the receiver. The Band Preset can be manually changed to scan any supported range.
- Alerts logged when devices first come online may list device parameters and their values as they are being discovered even though the parameter values themselves have not changed.
Notes
- In order to monitor and control networked devices, you must be connected to the same subnet. Cross-subnet connections to a network of gear are not supported.
- Tags that have been added to a show file but are not assigned to any devices are not saved within the show file.
- Opening show files created with older versions of Wireless Workbench may result in the Settings Conflicts dialog opening once the file has loaded. This is due to newly supported hardware parameters that have been introduced with updated firmware versions. To maintain all settings from the show file, select "Keep all settings from: Wireless Workbench".
- On machines running Windows 7, Wireless Workbench will not be able to discover devices when the machine has fallen back to its 169.254.xxx.yyy fallback IP address, regardless of the IP addressing of the connected Shure devices. To address this, perform one of the following:
- Insert a DHCP server onto your network and set your machine and Shure devices to accept automatic IP addressing.
- Statically assign your machine's IP address to the 169.254.xxx.yyy fallback subnet with a different IP address than the one it fell back to originally.
Oprogramowanie
6.11.2
July 29, 2015
Zobacz wszystkie aktualizacje
New Features
Added Site Survey (902 - 928 MHz) Utility, which utilizes ISM-band devices to capture long-term scans and generates processed scan data, tailored specifically for coordination in this spectrum. Access this utility by selecting Tools > Site Survey (902 - 928 MHz).
- This utility is designed to use an ISM-band Shure receiver to assess whether a particular venue is well suited for ISM-band operation of fixed frequency microphone systems.
- This utility includes the “Usability Report”, which runs sample calculations and reports an approximate number of usable channels in the ISM band.
- For more information, consult the WWB6 Help System.
Improvements
- Added support for new ULX-D bands in the ISM range: X52, X53, X54.
- Added support for new BLX bands: H9, H10.
- Fixed bugs regarding deleting frequencies in the Coordination Workspace, and enabled deleting frequencies with the “Backspace” key as well as the “Delete” key.
- Fixed TV Data for Italy and the Netherlands.
- Fixed bug that would hide channel markers (from Inventory) in the Frequency Plot.
- Fixed bug that would prevent scanning with MW4 receivers.
Known Issues
- If you are running the Mac OS X Yosemite Operating System, be sure to run version 10.10.4 or later. Earlier beta versions of the Operating System are not supported.
- On Macs, when users open show files and launch the Frequency Analysis dialog (by checking the checkbox and pressing “Analyze”), the Frequency Coordination tab may stop responding to keyboard inputs (for example, editing or deleting frequencies with the keyboard). To work around this issue, select another tab in the application (e.g.: Inventory or Monitor) and then reselect the Frequency Coordination tab.
- SLX and ULX frequencies in Master List mode cannot be manually entered in the Coordination Workspace. They can, however, be coordinated and analyzed.
- When scanning with AXT400 receivers, the Band Preset value in the Live Scan Settings dialog does not always stay in sync with the currently selected band of the receiver. The Band Preset can be manually changed to scan any supported range.
- Alerts logged when devices first come online may list device parameters and their values as they are being discovered even though the parameter values themselves have not changed.
Notes
- In order to monitor and control networked devices, you must be connected to the same subnet. Cross-subnet connections to a network of gear are not supported.
- Tags that have been added to a show file but are not assigned to any devices are not saved within the show file.
- Opening show files created with older versions of Wireless Workbench may result in the Settings Conflicts dialog opening once the file has loaded. This is due to newly supported hardware parameters that have been introduced with updated firmware versions. To maintain all settings from the show file, select "Keep all settings from: Wireless Workbench".
- On machines running Windows 7, Wireless Workbench will not be able to discover devices when the machine has fallen back to its 169.254.xxx.yyy fallback IP address, regardless of the IP addressing of the connected Shure devices. To address this, perform one of the following:
- Insert a DHCP server onto your network and set your machine and Shure devices to accept automatic IP addressing.
- Statically assign your machine's IP address to the 169.254.xxx.yyy fallback subnet with a different IP address than the one it fell back to originally.
Oprogramowanie
2.2.0
May 29, 2015
Zobacz wszystkie aktualizacje
Improvements
- Added support for updating GLX-D devices, including
- GLXD1 - Bodypack transmitters
- GLXD2 - Handheld transmitters
- GLXD4 - Baggable receiver
- GLXD6 - Guitar Pedal receiver
Known Issues
- Microflex Wireless devices running version 1.X firmware must first be updated to version 2.0.5 before being updated to version 3.X or later.
Notes
- Simultaneous updating more than one GLX-D device is not supported.
- Installing the Shure Update Utility on Windows machines will prompt the installation of a USB driver in addition to the original application. This driver must be installed to support updating USB devices, like GLX-D.
- The use of USB hubs is not recommended when performing updates to GLX-D devices. Always connect a GLX-D device directly to a USB terminal of the computer running the Shure Update Utility.
- This version of the Shure Update Utility is compatible with the following other versions of software applications:
- Wireless Workbench 6.11.0
Oprogramowanie
6.2.202
May 18, 2015
Zobacz wszystkie aktualizacje
New Features
- Registration Reports added
- Agenda Subject Vote Reports added
- Existing reports updated to harmonize the look of the reports
- New command line parameter ReportLabelId will add label ID number in front of each label for any reports, both visible in CAA and in the printed report. Command: -ReportLabelId
Improvements & Bug Fixes
- Delegate Seat Table layout improved
- Voting pie animations improved
- Microphone and Voting Mimic improved
- Agenda and voting CUA control improvements
- CUI now broadcasts individual votes also when voting is paused, making CUA showing the voted option when a vote is cast while voting is paused
- Bug fix: Predefined messages are received, but empty on DC 69xx
- Bug fix: Incorrect User Type for prepared delegate conference
- Bug fix: Microphone/mimic control error when using Chip Cards with ‘No login’ conference
- Bug fix: Microphone list and button shows incorrect status (for 'No login' and when no active conference)
- Bug fix: Voting result color not updated, when voting is paused
- A number of minor bug fixes
Oprogramowanie
6.11.0
April 23, 2015
Zobacz wszystkie aktualizacje
New Features
- Added Item Properties sidebar, enabling batch edits of devices and channels in the Inventory tab.
- Stage parameter changes to multiple channels or devices in the Properties sidebar, and send them all at the same time.
- Assign increasing numerical values to Device ID or Channel Name with “Auto-enumerate”
- The Coordination Workspace in the Frequency Coordination tab allows for the selection of subsets of Inventory channels to consider during Frequency Coordination.
- Perform coordinations for subsets of channels to accomplish time or location based frequency coordination.
- Bring frequencies in from the Inventory via “Select Frequencies from Inventory”.
- Additional frequencies (including backup frequencies) can be added to the Coordination Workspace via “Request Additional Frequencies”.
- Drag and drop frequency markers in the plot view to reposition them (and their frequency values) in the spectrum.
- Leverage Analysis results to keep compatible frequencies and only recalculate incompatible frequencies.
- Review and adjust assignments of ranked frequencies to channels prior to deployment.
- Save and recall coordinations with Coordination Workspace (.cws) files.
- The Monitor Tab has been completely redesigned.
- Channel strips have been redesigned to have a uniform layout, and can be customized with the Channel Strip Designer.
- Condensed Metering displays RF and Audio meters as a single LED, for quick sign-of-life referencing.
- Customize the arrangement of channel strips with “Auto”, “Free”, and “Snap” modes.
- Resize channel strips for better visibility or emphasis of important channels.
- Organize Channel Strips into Groups and Views.
Improvements
- ULX-D receivers have the ability to disable Interference alerts. This property can be set from the Properties Panel.
- AXT610 Axient ShowLink Access Points now have the ability to be rebooted from Wireless Workbench 6. This action can be triggered from the Properties Panel.
- The selection of Group and Channel has been separated for more convenient selection of a particular group and channel value.
- Tags are now managed from the Tag Manager dialog. To access this view, select Tools > Manage Tags.
- Zones are now managed from the Zone Manager dialog. To access this view, select Tools > Manage Zones.
- Added right sidebar to plot with controls to adjust plot view, adjust exclusion threshold, and control visibility of the inclusion/exclusion ranges considered by the calculator, including TV Channels, Additional Exclusions (those manually entered or generated from scan data), Inclusion Groups, and User Groups.
- Assign different colors to exclusion/inclusion ranges by clicking on the color swab in the right sidebar and picking a different color.
- Assign colors to Inclusion Groups in the Inclusion Lists dialog by right-clicking on a group and selecting “Assign Color”. Inclusion Groups’ colors will be displayed as ranges on the plot view when selected in the plot’s right sidebar.
- Default Gateway can now be specified for all networked Shure devices via the Properties Panel.
- NOTE: Wireless Workbench 6 cannot control devices across subnets. Default Gateway addressing permits device communication with Third Party Control Strings to traverse subnets.
- Added full support to enable UHF-R transmitters to sync to AXT400 J receivers (including syncing of Custom Groups).
- Added support to select “Inclusion Groups” in the Add New Device dialog.
- Added support to handle frequency coordinations for PSM300 in terms of Groups and Channels.
- Updated TV Data for Australia, Denmark, Belgium, The Netherlands
Known Issues
- When scanning with AXT400 receivers, the Band Preset value in the Live Scan Settings dialog does not always stay in sync with the currently selected band of the receiver. The Band Preset can be manually changed to scan any supported range.
- When importing show files that contain a deployed frequency list, channels in that list with a custom equipment profile type will not be removed from the backups section of the Channel Summary dialog regardless of whether the custom profile is stored on the local machine's equipment profiles database. The calculator will not be able to coordinate frequencies until all channels are removed from the backups section for which there is not a custom equipment profile.
- Alerts logged when devices are first come online may list device parameters and their values as they are being discovered even though the parameter values themselves have not changed.
Notes
- Requested backup frequencies from show files created with WWB 6.10 or earlier will not be imported after the show file conversion in WWB 6.11.
- In order to monitor and control networked devices, you must be connected to the same subnet. Cross-subnet connections to a network of gear are not supported.
- Tags that have been added to a show file but are not assigned to any devices are not saved within the show file.
- Opening show files created with older versions of Wireless Workbench may result in the Settings Conflicts dialog opening once the file has loaded. This is due to newly supported hardware parameters that have been introduced with updated firmware versions. To maintain all settings from the show file, select "Keep all settings from: Wireless Workbench".
- On machines running Windows 7, Wireless Workbench will not be able to discover devices when the machine has fallen back to its 169.254.xxx.yyy fallback IP address, regardless of the IP addressing of the connected Shure devices. To address this, perform one of the following:
- Insert a DHCP server onto your network and set your machine and Shure devices to accept automatic IP addressing.
- Statically assign your machine's IP address to the 169.254.xxx.yyy fallback subnet with a different IP address than the one it fell back to originally.
Oprogramowanie
6.2.184
December 3, 2014
Zobacz wszystkie aktualizacje
New Features
CDA
- Customer Requests Asia BU: Backgrounds Images and variables in CDA
- North Sydney City Council, Jands: CDA Mimic vote cast indication
- CDA now supports using transparent background pictures
Bug Fixes
- CAA Cant delete a Conference where voting has been conducted twice on same agenda subject.
- CDA UI jitters when sorting is involved (Individual voting results display) - partly corrected
- CDA Voting graphics are jumping / jittering
- CUI: Default Microphone mimic not visible on CDA until CUI is restarted
- CDA background image Vertical 'top, center, bottom' parameters are not always reflected on display
- CDA Typewriting and animation improvements to e.g, speaker list
- CDA Exception when renaming the mimic
- CAA / CDA Configuration - Prepare conference text – secondary language not used by CDA
- CAA Conferences - can't delete conferences when using search field
- CUA: Microphones with CUA attached not visible in Mic. ext list
- CU Exceptions in VSS log when operating microphones fast
Oprogramowanie
6.10.3
November 14, 2014
Zobacz wszystkie aktualizacje
Improvements
- Fixed bug which would not display Group and Channel for frequencies coordinated for PSM300 In-Ear Monitor systems, as well as FP and BLX wireless systems.
- Added support to repair a rare networking issue with Duplicate Dante MAC Addresses for Dante-enabled ULX-D receivers. Note: this fix requires updating ULX-D to firmware version 1.5.18.
- Added support for Mac OS X 10.10 Yosemite.
Known Issues
- When scanning with AXT400 receivers, the Band Preset value in the Live Scan Settings dialog does not always stay in sync with the currently selected band of the receiver. The Band Preset can be manually changed to scan any supported range.
- When importing show files that contain a deployed frequency list, channels in that list with a custom equipment profile type will not be removed from the backups section of the Channel Summary dialog regardless of whether the custom profile is stored on the local machine's equipment profiles database. The calculator will not be able to coordinate frequencies until all channels are removed from the backups section for which there is not a custom equipment profile.
- Alerts logged when devices are first come online may list device parameters and their values as they are being discovered even though the parameter values themselves have not changed.
Notes
- In order to monitor and control networked devices, you must be connected to the same subnet. Cross-subnet connections to a network of gear are not supported.
- Tags that have been added to a show file but are not assigned to any devices are not saved within the show file.
- Opening show files created with older versions of Wireless Workbench may result in the Settings Conflicts dialog opening once the file has loaded. This is due to newly supported hardware parameters that have been introduced with updated firmware versions. To maintain all settings from the show file, select "Keep all settings from: Wireless Workbench".
- On machines running Windows 7, Wireless Workbench will not be able to discover devices when the machine has fallen back to its 169.254.xxx.yyy fallback IP address, regardless of the IP addressing of the connected Shure devices. To address this, perform one of the following:
- Insert a DHCP server onto your network and set your machine and Shure devices to accept automatic IP addressing.
- Statically assign your machine's IP address to the 169.254.xxx.yyy fallback subnet with a different IP address than the one it fell back to originally.