Downloads
Archiwum oprogramowania i firmware
Oprogramowanie
1.0.1
April 19, 2021
Zobacz wszystkie aktualizacje
Important
- Firmware must be on 1.4.3 to use the new SCM820 application.
Improvement
- Fixed an issue with the app freezing when connecting to SCM820 with some Windows machines.
Known Issues
- Not all settings from the previous Flash UI are available with the new SCM820 application.
- Refer to new SCM820 user guide online for new SCM820 application settings
- Network settings cannot be adjusted in the new SCM820 application.
- Use MXW Software application for Shure Control settings and Audinate Dante Controller for device and Dante settings
- A message from Windows may pop up during installation stating the app may harm the computer. This is a Windows default message for new unknown apps. You may disregard and install. Here’s a link for more info: https://docs.microsoft.com/en-us/archive/blogs/smondal/windows-smartscreen-prevented-an-unrecognized-app-from-running-running-this-app-might-put-your-pc-at-risk
- Preconfigured devices with settings not available in the new SCM820 application will remain on the device until a factory reset is done. A factory reset will clear all settings back to defaults.
- Opening the application using DNS name may fail. This may be a network or Windows 10 limitation. Use IP address as a workaround.
- A lower spec PC may have a temporary processor hit when opening the application.
- When uninstalling, Windows may ask to close the application if running. The application closing may fail. The application will uninstall but continue to run if left open. Close all instances of the application to complete uninstalling.
Notes
- New SCM820 application in English only
- The user guide online is in English only
- To access multiple SCM820s, multiple instances of the application may be opened.
Oprogramowanie
1.1.0
April 12, 2021
Zobacz wszystkie aktualizacje
New Features
- Auto App Update
- Ability to update software from within the application instead of downloading the newest version from Shure.com
- MV7 Users:
- Use LED as Live Meters
- Night mode
Improvements
- Bug fixes
Notes
- MV7 User Guide
- Compatible with macOS Mojave, High Sierra and Catalina, and 64-bit versions of Windows 7, 8 and 10
- ShurePlus MOTIV 1.1.0 is compatible with the following firmware versions:
- MV7 1.2.12
- MV88+ 1.1.12
Oprogramowanie
1.0.0
March 30, 2021
Zobacz wszystkie aktualizacje
Important
- Firmware must be on 1.4.3 to use the new SCM820 application.
New Features
- SCM820 Software Application for Windows 10
Known Issues
- Not all settings from the previous Flash UI are available with the new SCM820 application.
- Refer to new SCM820 user guide online for new SCM820 application settings
- Network settings cannot be adjusted in the new SCM820 application
- Use MXW Software application for Shure Control settings and Audinate Dante Controller for device and Dante settings
- Preconfigured devices with settings not available in the new SCM820 application will remain on the device until a factory reset is done. A factory reset will clear all settings back to defaults
- Opening the application using DNS name may fail. This may be a network or Windows 10 limitation. Use IP address as a workaround
- A lower spec PC may have a temporary processor hit when opening the application.
- When uninstalling, Windows may ask to close the application if running. The application closing may fail. The application will uninstall but continue to run if left open. Close all instances of the application to complete uninstalling
Notes
- FAQ
- This application is available in English only
- The user guide online is in English only
- To access multiple SCM820s, multiple instances of the application may be opened.
Oprogramowanie
9.3.0
March 17, 2021
Zobacz wszystkie aktualizacje
Important
- This software version is used for new SW6000 installations or to update all previous SW6000 installed versions using DIS-CCU Central Unit (CU 6005, CU 6010, CU 6011. CU 6105, CU 6110 and CU 5905 are not supported)
- This version is compatible with SW6000 Software License file v1.7 only
- No new SW6000 license is needed if updating from SW6000 v6.0.xxx or later versions
- A new SW6000 license is needed if updating from SW6000 v5.8.xxx or previous versions
New Features
- System
- ‘Chairman’ changed to ‘Chairperson’
Bug Fixes
- System
- Participants created using CAA during a meeting (Login using code card) cannot log into the meeting.
- All applications – About windows – the HTML page for 3rd-party licenses has some broken links.
- CUA
- If a participant is logged into a meeting using a secondary language (not the meeting default), the participant will see entries in the speak list using ‘show name’ as defined for the system language.
- Number of speeches for a speaking delegate will be set to 0 if delegate is speaking while an agenda subject is active, and subject is set as not active. Number of speeches count remain 0 if a new subject is set active.
- Using microphone control, a participant speaking at their own microphone can be moved to podium – if another participant is also speaking, both participants will have speech time reset – only the participant moved to podium should have speech time reset.
- Using Microphones Control [Next on] button to put a microphone from the request list into speak, the button changes to [Mic off] – it should remain [Next on], as no microphone is selected.
- Users that are set as inactive in the database do not appear in the Participant list if they log into a meeting.
- MXC640 speak list etc. can show different ‘Seat no.’ information from what’s defined in the SW6000 suite and displayed in CUA.
- CAA
- Meeting role agenda options field ‘Description’ cannot be selected if ‘Title and short description’ has not been checked.
- In the meetings screen, if a user selects a meeting and uses Up/Down keyboard keys (↑ ↓) to change meeting selection, these keys may stop working until meeting is reselected using the mouse.
- Selecting “Program ‘User ID / Login code’ on card” displays the window – but the window title is “ID cards”.
- Deleting a Namesign template in a multi-language system where the template does not have a name in all languages can cause an exception.
- Deleting all meetings, creating new meetings and then deleting them can cause an exception.
- Deleting existing meetings and adding a new meeting can cause an exception (addition fails).
- Editing a meeting where only Meeting ID is changed, it’s not possible to update data in the database.
- CUI
- An MXC640/DC69 unit seat set up in a ‘Prepared participant seat table’ meeting without a delegate assigned displays seat information as defined in the CCU component GUI – this should be seat number.
- Microphone unit speak priority may persist as having no speaking rights if the CUI application is shut down while in an active meeting where a microphone has had speaking rights removed due to ‘One speech per subject’ functionality.
Notes
- To operate MXC devices with SW6000 version 9.3.0, see the following list of minimum software and firmware versions:
- MXC firmware release 9.2.0 or later
Oprogramowanie
3.0.1
February 23, 2021
Zobacz wszystkie aktualizacje
Important
- If currently running IntelliMix Room 1.0, you must update to 2.0 first before installing 3.0
Improvements
- Performance optimizations that improve stability of IntelliMix Room on lower-tier computers.
- Addition of mute sync and call status capability with supported video conferencing platforms.
- Command strings were added to control the gain and routing of Matrix Mixer cross points.
- Added the ability to route PC Input to PC Output via the Matrix Mixer.
- Improvements were made to the network settings page within the system tray application to handle disconnected or disabled Network Interface Cards (NICs).
- Release date was added to the system tray application software update notifications.
- Improvements were made to the system tray application notifying users if there are internet connectivity issues while trying to trigger a software update.
- Security improvements regarding software update from the system tray application.
- Added the ability to show/hide the license ID for IntelliMix Room within the system tray application.
Bug Fixes
- Resolved an issue with automatic check for updates during installation of IntelliMix Room.
- Uninstaller improvements preventing false-positive virus detection with Mcafee, Symantec, and Rising endpoint protection software.
- Resolved issues with Realtek drivers needing to be re-selected as the PC I/O device in IntelliMix Room after Realtek driver updates.
- Resolved issues with version reporting in Designer software.
- Installer improvement notifying user if installation cannot be completed due to issues with PowerShell, as opposed to claiming that there is no solid-state drive (SSD) detected even if the system drive is an SSD.
- Resolved audio performance issues introduced by system stress of high-definition video peripherals such as cameras, displays, and screen sharing.
Known Issues
- Packet scanning security software may cause audio performance issues with IntelliMix Room.
- In order to transition from a trial license to a paid license before trial expiration, the IntelliMix Room endpoint must be deactivated and reactivated. Otherwise, the entire trial license term will be used before the paid license.
- When using Dante Domain Manager (DDM) and the configuration for the device is set to “prevent” or the DDM server is offline, you can still upgrade IntelliMix Room.
- Changing the System Name of the host computer after installation of IntelliMix Room also changes the Dante Device name in Dante Controller. The Shure device name stays the same. This does not affect device performance and can be ignored.
- Ensure that the system/device name of the computer running IntelliMix Room is unique and follows Microsoft Window’s recommendation of 15 characters or less. IntelliMix Room relies on this unique name for proper Shure and Dante network operation.
- IntelliMix Room occasionally uses more resources on Dell XPS Laptops.
- Certain Bluetooth devices may not persist in the PC Input/Output device dropdown selection after a restart of the computer. Audio will still pass.
- If you adjust certain networked audio properties (networked audio device name, encryption state, license channel count), IntelliMix Room briefly goes offline in Designer.
- In some scenarios, the computer running IntelliMix Room must be rebooted after a Zoom Rooms update occurs on the same computer.
- In some situations, the “IntelliMix Virtual Audio” audio driver can be left on the operating system after the uninstallation of IntelliMix Room. A reboot of the system resolves the issue.
- Allowing a system running IntelliMix Room to enter a sleep state can cause issues with IntelliMix Room’s logic and mute sync functionality. A reboot of the computer resolves the issue.
- Performing a factory reset of IntelliMix Room will clear the user event logs.
Notes
- User Guide
- Installation and Deployment Guide
- Quick Start Guide
- IMX Room 3.0 is compatible with the following software and firmware versions:
- Designer 4.4.0
- MXA910 4.4.11
- MXA310 4.4.9
- MXA710 1.2.1
- MXA Mute 1.2.4
- P300 4.4.13
- ANIUSB-MATRIX 4.4.14
- ANI22 4.4.8
- ANI4IN 4.4.8
- ANI4OUT 4.4.8
- Microflex Wireless 8.0.3
Oprogramowanie
4.4.1
February 23, 2021
Zobacz wszystkie aktualizacje
Important
- Upgrading directly from older versions such as SystemOn 3.0 or 3.1 to this version is not supported, nor is importing project files from 3.0 or 3.1 directly into 4.4.1; it's recommended that you upgrade to version 3.2 first (download here), then to 4.4.1 to maintain all projects.
- After upgrading SystemOn, clear your browser cache on the device accessing the SystemOn server, then re-assign your licenses to your devices by navigating to your organization > Licenses > Start managing
- SystemOn cannot be installed on the same machine as Designer; do not attempt to install one over the other
- Before updating firmware, turn off “Device Missing” notifications, then turn them back on after completing the firmware updates
- SystemOn may not allow downgrading of some P300s due to a platform update to support future functionality and USB improvements.
Improvements
- Support for latest firmware — see the Notes section below for compatible versions
Bug fixes
- ‘System not available' screen shows when opening SystemOn depending on Microsoft VC++ Redistributable versions installed on the machine
- Various other bug fixes
Known Issues
- When using a virtual machine, it’s recommended to dedicate hardware resources (HD, RAM, etc.) to the SystemOn application; using shared resources may cause Shure services to not start on reboot
- When a device is being firmware updated, it will appear offline during the update in SystemOn
- ULX-D transmitters using non-Shure batteries will show in the transmitter list with incorrect values for battery cycle count and health
- After attempting to forget cross-subnet devices, devices must be rebooted, then SystemOn server must be rebooted before the devices will disappear from SystemOn
- Discovering MXW microphones may take more than 1 minute
- UTC time and date are displayed on Event Log and Email/SMS notifications.
- For users setting up SMS notifications, the Senders Phone Number field does not show the required (*), but the field is required.
- If a valid license activation ID is applied and fails on the first attempt, please try again before calling support.
Notes
- Internet access is no longer required during the installation process; however, use of certain features like firmware updating and text notifications require internet access
- Designer and SystemOn cannot be installed on the same machine
- To operate SystemOn 4.4.0 with Shure networked systems, see the following list of supported firmware versions:
- MXW 8.0.3 – 9.0.4
- SCM820 1.3.3
- ULX-D 2.2.24 – 2.4.25
- SBC220/240 1.1.43 – 1.2.73
- SBC250/450/850 2.2.24 – 2.4.13
- MXA910 4.1.41 – 4.4.11
- MXA710 1.1.X –1.2.1
- MXA310 4.1.37 – 4.4.9
- P300 4.1.11 – 4.4.13
- IMX-ROOM 1.0.4.2 – 3.0.1
- ANIUSB-MATRIX 4.1.39 – 4.4.14
- MXN5-C 1.1.X – 1.2.1
- MXA-MUTE 1.1.X -- 1.2.4
- Please report SystemOn performance issues experienced on supported browsers to Shure Support.
- For help and troubleshooting, go to the SystemOn System Requirements, SystemOn User Guide or FAQs
Oprogramowanie
4.4.1
February 23, 2021
Zobacz wszystkie aktualizacje
Important
- Before upgrading Designer versions, it’s recommended to export project files to back them up.
- Upgrading directly from old versions such as Designer 3.0 or 3.1 to version 4.4 is not supported, nor is importing project files from 3.0 or 3.1 directly into 4.4; it’s recommended to upgrade to 3.2 first, then to 4.4 to maintain all projects.
- If you encounter an installer failure during upgrade, allow the uninstaller to finish, then restart installation.
- Certain endpoint protection software may block the application; whitelist the Designer installer or application to fix this.
- In order to push from virtual devices to online devices, or vice versa, the virtual device and online version must be on the same version. For example, new virtual devices created in Designer 4.4 are on version 4.4.X; those virtual devices can only be associated with online devices that are also on version 4.4.X.
- windDesigner 4.4 is not backwards compatible with earlier versions of Designer. The database will not be maintained upon downgrading, and Designer 4.4 files cannot be imported into earlier versions of Designer.
- Designer may not allow downgrading of some P300s due to a platform update to support future functionality and USB improvements.
Improvements
- Device type support for ANIUSB
- Note: Codec must support echo cancelation with ANIUSB
- Call status support for P300, IMX-Room, and ANIUSB
Bug fixes
- “Network ID is not valid” error in installer when Windows username contains a space
- Installer error due to corrupted PowerShell setup
- Various other bug fixes
Known Issues
- With more than 20 devices in location or 60 on the network, some actions will take longer due to increased network traffic.
- When a device is being firmware updated, it will disappear and reappear in Designer.
- When importing a Designer preset file into the MXA910 web application, attempts to immediately export that file out of the web application will fail if it is not first loaded and saved to the MXA910.
- When soloing a channel on an MXA310, all channels will show as gated on
- When enabling or disabling encryption or changing the Dante name on the IMX-Room, the device will go offline for a few seconds without warning
- When one or more devices in a location are locked by Dante Domain Manager or Dante Device Lock, operations that affect Dante settings may be unreliable, such as audio routing, pushing virtual to online devices, or enabling audio encryption
- Changing channel count of virtual IMX-Room device does not reset audio settings
- When disassociating online devices from virtual devices multiple times, Optimize may not create expected routes; add new virtual devices and Optimize
- Indications that show on the bottom of the Coverage map page may persist longer than expected
- Forgetting a cross-subnet MXA910 on firmware version 4.1.41 may result in the device being rediscovered; close and re-open Designer or reboot device to see it as forgotten
- When factory resetting a device from Online Devices > Device window, then attempting to add that device to a Location that’s already open and initializing it, the Location and Device window will close; reopen to continue working
- Users with Astrill VPN installed will not be able to launch the app successfully; contact Shure support for help
- When using IntelliMix Room, Designer may show a red dot and invalid software version for that device after installation. Close and re-open Designer or reboot the machine running IntelliMix Room to fix the issue.
- Mute Sync will not work between P300 devices running version 4.2 and 4.3 firmware. Please make sure to update all P300s in a system to version 4.3
Notes
- Designer and SystemOn cannot be installed on the same machine
- Designer User Guide
- Designer 4.4.0 is compatible with the following software and firmware versions:
- MXA910 4.4.11
- MXA710 1.2.1
- MXA310 4.4.9
- IMX-Room version 3.0.1
- P300 4.4.13
- ANIUSB-MATRIX 4.4.14
- MXN5-C 1.2.1
- MXA-MUTE 1.2.4
- Requires 64-bit Windows 10
- Minimum system requirements have been updated; please see Designer User Guide
Oprogramowanie
9.2.0
February 11, 2021
Zobacz wszystkie aktualizacje
Important
- This software version is used for new SW6000 installations or to update all previous SW6000 installed versions using DIS-CCU Central Unit (CU 6005, CU 6010, CU 6011. CU 6105, CU 6110 and CU 5905 are not supported)
- This version is compatible with SW6000 Software License file v1.7 only
- No new SW6000 license is needed if updating from SW6000 v6.0.xxx or later versions
- A new SW6000 license is needed if updating from SW6000 v5.8.xxx or previous versions
New Features
- System
- Performance improvements
- CUA
- Changed button layout on the Agenda screen to facilitate new features
- Support MXCMIU as interpreter source
- Option to add Subject notes and Meeting notes to the Meeting Agenda
- CAA
- Auto-numbering of agenda items
- Support MXCMIU as interpreter source
- ‘Voting comments’ option has been removed and replaced by ‘Subject notes’
- When updated, the content of ‘Voting comments’ is moved to ‘Subject notes’
- Option to add Subject notes and Meeting notes to the Meeting Agenda
- Add Meeting note to Meeting export
- Add Notes to Agenda export
- Add Notes to Agenda reports
- Added Meeting Role options for Notes:
- View
- View/Edit
- Hyperlink option moved to a tab on the Agenda screen
- Support using NFC card ID from Mifare/Desfire/ACOS3 cards
- ID card support for affiliating unique card ID with a user
- Card ID included in User Table import/export and Meeting import/export
- Card enable/disable option removed
- The previous behavior where the application should be re-started if use of cards were enabled/disabled has been removed and replaced with a ‘Login mode’ option in ‘Meeting options’:
- Use login code
- Use card programmed with ‘User ID / Login code’
- Use NFC card affiliated with user
- The previous behavior where the application should be re-started if use of cards were enabled/disabled has been removed and replaced with a ‘Login mode’ option in ‘Meeting options’:
- Important
- SW6000 cannot program any meeting data on a Mifare/Desfire NFC card
- English labels updated
- Although there are many updated labels, the existing labels do not automatically change when updating SW6000 from a previous version. It is therefore recommended to import the English labels, which can be found in the SW6000 installation package in the ‘SW6000 Accessories|SW6000 Labels’ folder
Bug Fixes
- Installer
- If the ‘One PC’ option is selected when installing applications, the selected default language is ignored, and US English is always used.
- CUA
- Microphone control may become slow if many users enter the request list – can lead to a Windows Message giving the user the option of closing the non-responsive application.
- Speak list may become out of sync between hardware and CUA microphone control – can happen for fast control in a large system switching a microphone on at the podium position from the last speaker list.
- Individual vote result screen may display wrong colors for delegate vote
- Slow (Speaking too fast) indication is incorrectly cleared if present when starting (e.g. a Prepared delegate list meeting)
- When using speech time, the speakers list in the Microphones control does not display a counting timer. (Main screen speak/request list does)
- When speech time is enabled incorrectly, users with no speak button but microphone control enabled, will see the speech time indication overlaying the keyboard microphone control edit box
- Speech time alarm does not display red ‘alert’ color for the selected row in speakers’ grid.
- Audio Output screen channel selection for one of the outputs has an unwanted selection option of ‘0 ’. This option is removed.
- Speech time increment cannot be adjusted using up/down arrows.
- Microphone control: For a ‘Prepared participant list’ meeting, the participants extension control will display all seats with assigned delegates, but only some seats that are not on the delegate list.
- Voting Result: Votes status extension control displays ‘Quorum reached’ and ‘Registration quorum reached’ fields overlapping.
- Moving a chairman who is speaking from his seat to the podium causes the name to be missing on the podium.
- If a seat without any participant is selected, the info in Participant info on the Microphone screen is wrong, showing the last selected Participant and not the selected seat.
- Info in Participant info on the Microphone screen is taken from wrong language
- Button ‘Not Initialized’ in Agenda view for delegate using one of the low resolutions when delegate does not have rights to set a subject active.
- CAA
- Export of participant list to XML from a meeting fails if the list contains empty seats.
- Selecting multiple conference units in CAA->Conference units and pressing [Delete] button creates an error and units are not deleted
- Application creates an exception if CUI is restarted while the CAA user has the AO setup window open.
- Updating a voting configuration with an invalid formula will display a warning, but still save the invalid formula in the database.
- Audio output unit window may give an exception when user tries to delete unit
- In the meeting, importing the same agenda from XML file twice will cause an exception.
- Voting configuration: Using the voting formula SUM(Button1) will create an error message. The formula is valid and should not create an error message.
- Meeting options: TAB order of control focus is incorrect.
- Meeting role window can be resized below minimum size that displays all controls.
- Size and position of the CAA is not stored/recovered
- Changing booth for MXC605 IS, resets the ‘comment’ text field for the unit.
- If a user with Delegate role selected opens the ‘Meeting Role’->’Agenda options’ window and then closes the window again, the Meeting role will be in the ‘update pending’ state. Since the user made no changes, there should be no pending update.
- If a user edits the speech time configuration and this configuration is currently in use, an exception may be raised. It should not be possible to update the active speech time configurations.
- Can’t create a ‘Detailed participant statistical report’ for a delegate if delegate has not spoken in any meeting for the selected period.
- CAA/CUI
- Set up an agenda subject configuration to reset group speech time when an agenda subject is set active. Setting a subject with this configuration active does not reset speech time.
- Set up an agenda subject configuration to reset participant speech time when an agenda subject is set active. Setting a subject with this configuration active does not reset participant speech times.
- CDA
- Skin Editor: Interpretation Items: Bold and Italic settings are missing and have wrong impact
Known Issues
- None
Notes
- These release notes include notes from the not-released SW6000 version 9.1
- To operate MXC devices with SW6000 version 9.2, see the following list of minimum software and firmware versions:
- MXC firmware release 9.2.0
Oprogramowanie
9.2.0
February 11, 2021
Zobacz wszystkie aktualizacje
Release notes cover the following models:
- MXC605/605-F
- MXC615
- MXC620/620-F
- MXC630/630-F
- MXC640
- MXCIC
- MXCMIU
- MXCSIGN
- DIS-CCU
- AO6004
- DC5900F
- DC5980P
- DCS6000 legacy conference and interpreter units
Important
- This firmware release can be used to update:
- Microflex Complete (MXC) or DCS 6000 systems using DIS-CCU Central Unit
- DC5900F and DC5980P to register and work in an MXC system
- Systems using CU 5905, CU 6000, CU 6005, CU 6010, CU 6011, CU 6105, or CU 6110 Central Units are not supported in this release
- The update requires using the Firmware Update Utility (FUU) included in this release
New Features
- System
- Support for Mifare/Desfire card when used with SW6000
- When using SW6000, the MXC system can now be configured to provide:
- The User ID/Login code data from ACOS3 NFC cards programmed from SW6000 (current feature) or
- The Unique ID on a Mifare/Desfire NFC card or an ACOS3 NFC card (new feature)
- Benefits
- Using the Unique ID enables usage of cards where no (meeting) data has been written to the card
- This makes it possible to use cards that are provided to users for other purposes to login to SW6000, so the user needs to hold one less card
- Important
- Mifare/Desfire NFC cards can only be used with SW6000 connected, not in a standalone system
- When using SW6000, the MXC system can now be configured to provide:
- Support for Mifare/Desfire card when used with SW6000
- DIS-CCU
- Support for setting output/level on the AO6004 Audio Output unit
- Additional languages – Polish & Croatian
- System Information Report – Information content updated
- Support for configuring MXCMIU as Interpreter source
- Support for configuring MXC605 as a voting unit
- Alternate LED indications. Option to set the microphone ‘Speak/Request color’:
- Red speak | Green Request
- Green speak | Green Request
- Option to disable the Request indication in the gooseneck microphone
- Disable Global language selection (CGUI) when SW6000 is connected
- MXCMIU
- Interpreter Source option
- MXC640
- Additional languages – Polish & Croatian
- Expand Agenda Prefix
- MXC605
- Option with new overlay: Voting 2- and 3-buttons, Attendance check, Secret/open voting
- MXCIC
- Expand Agenda Prefix
- MXCSIGN
- OS updated to allow the use of the USB connector together with the ‘Shure MXCSIGN App’. The app allows to transfer a defined picture to the sign
- TPCI
- ‘Speak Slow’ support
- MIU interpreter source option
Bug Fixes
- System
- Ambient sound disappears when switching to VOX mode
- CCU
- Web GUI removes only a single unregistered unit at 'Remove unregistered units'
- Web GUI – Indication in buttons in Diagnostic screen updated
- Diagnostic – last unit on a chain is reported as lost when reconfigured into loop
- Floor1 and Floor2 is switched in the web GUI Channel-dropdown
- Force CCU-configuration to 1000 m of cable, when upgrading from earlier versions to Release 9.2.0
- The indication for 605 interpreter in 'Diagnostic' is wrong
- MXCMIU
- Function button indication is not turning blue, when configured as ambient mic
- MXC620
- Unit not reacting to card inserted, when location code is altered
- MXC620-F & MXC630-F
- Chairman left button configured as Exclusive can take over other units already in Exclusive state
- MXC630 and MXC630-F
- 3-Btn Secret voting with proxy – missing LED indication
- Cannot login to a meeting during a paused Voting session
- Indication in proxy button is not correct
- Secret voting – wrong LED indication
- MXC640
- "Attended" text is not translated
- Misleading texts corrected when logging in with card
- Missing clear feedback on buttons on login screen
- Present/seats value = 2000 are cut of in right side, and only 200 is shown
- Speech time display permissions are not working
- Voting not possible with meeting mode: No login
- MXCIC
- Some units are 'Locked' when the system is powered
- Unable to turn off "Audible Level Warning"
Known Issues
- Manually entered voting results are not shown if a normal voting session has not been started first
- The agenda subject name for a manually entered result may be wrong
- It is not possible to use an MXC640 configured as dual delegate with SW6000 if the use of NFC cards is enabled
Notes
- These release notes include notes from the not-released FW 9.1
- MXC and DCS 6000 firmware files are packaged together in the same release file.
- To operate MXC devices with FW release 9.2 with other Shure networked systems, see the following list of minimum software and firmware versions:
- SW6000 9.2.0
- Shure NFC Programming App 1.0.3
Oprogramowanie
2.5.1
February 3, 2021
Zobacz wszystkie aktualizacje
Important
- Shure Update Utility 2.5.1 does not support 32 bit.
- Shure Update Utility 2.5.1 does not support GLX-D, KSE1500, SHA900, and UHF-R
- Please use Shure Update Utility 2.4.8 to update these devices and for 32bit support.
Improvements
- Enhanced performance and stability of MXWANI updates.
- Improved reliability of updating legacy products.
Known Issues
- PSM1000 devices with firmware version 1.1.0 or earlier must use Shure Update Utility version 2.4.1 or older.
- Version 2.4.1
- Attempts to download ULXD6/8 transmitter firmware to a ULX-D or QLX-D receiver that is not at the minimum firmware version, shown below, will fail. To update firmware for ULXD6/8 transmitters with ULX-D or QLX-D receivers:
- Update receivers to the following minimum versions:
- ULXD4, ULXD4D, ULXD4Q Receivers 2.1.16
- QLXD4 Receivers 2.1.5
- Using Shure Update Utility, download ULXD6/8 transmitter firmware to the receivers.
- Using the FW Update menu on a receiver, update transmitters.
- Update receivers to the following minimum versions:
- Microflex Wireless devices running version 1.X firmware must first be updated to version 2.0.5 before being updated to version 3.X or later.
Notes
- Shure Update Utility is supported on the following operating systems:
- Windows 8.1 and 10
- Mojave (10.14) and Catalina (10.15)